Neonatal body composition:: Dual-energy X-ray absorptiometry, magnetic resonance imaging, and three-dimensional chemical shift imaging versus chemical analysis in piglets

被引:44
作者
Fusch, C
Slotboom, J
Fuehrer, U
Schumacher, R
Keisker, A
Zimmermann, W
Moessinger, A
Boesch, C
Blum, J
机构
[1] Univ Bern, Univ Womens Hosp, Div Neonatol, CH-3000 Bern, Switzerland
[2] Univ Bern, Dept MR Spect & Methodol, CH-3000 Bern, Switzerland
[3] Univ Bern, Clin Large Anim, CH-3000 Bern, Switzerland
[4] Univ Bern, Inst Anim Breeding, Div Nutr Pathol, CH-3000 Bern, Switzerland
关键词
D O I
10.1203/00006450-199910000-00018
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
An animal study to evaluate dual-energy x-ray absorptiometry (DXA) and magnetic resonance (MR) imaging and spectroscopy for measurement of neonatal body composition was performed. Twenty-three piglets with body weights ranging from 848 to 7550 g were used. After measuring total body water, animals were killed and body composition was assessed using DXA and MR (1.5 T; MR imaging, T-1-weighted sagittal spin-echo sequence; MR spectroscopy, three-dimensional chemical shift imaging) as well as chemical carcass analysis (standard methods) after homogenization. Body composition by chemical analysis (percent of body weight, mean +/- SD) was as follows: body water, 75.3 +/- 3.9%; total protein, 13.9 +/- 8.8%; and total fat., 6.5 +/- 3.7%. Absolute content of fat and total ash was 7-674 and 35-237 g, respectively. Mean hydration of fat-free mass was 0.804 = 0.011 g/kg and decreased with increasing body weight (r(2) = 0.419) independent of age. Using DXA, bone mineral content was highly correlated with calcium content (r(2) = 0.992), and calcium per bone mineral content was 44.1 +/- 4.2%. DXA fat mass correlated with total fat (r(2) = 0.961). Using MR, spectroscopy and chemical analysis were highly correlated with fat-to-water ratio (r(2) = 0.984) and absolute fat content (r(2) = 0.988). Total fat by MR imaging volumetry showed a lower correlation (r(2) = 0.913) and overestimated total fat by a factor of 2.46. Conversion equations for DXA were developed (total fat = 1.31 X fat mass measured by DXA - 68.8; calcium = 0.402 x bone mineral content + 1.7), which improved precision and accuracy of DXA measurements. In conclusion, bath DXA and MR spectroscopy give accurate and precise estimates of neonatal body composition and may become valuable tools for the noninvasive assessment of neonatal growth and nutritional status.
引用
收藏
页码:465 / 473
页数:9
相关论文
共 52 条
[1]   Use of proton MR spectroscopy and MR imaging to assess obesity [J].
BaracNieto, M ;
Gupta, RK .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (01) :235-238
[2]  
Barnard ML, 1996, NMR BIOMED, V9, P156, DOI 10.1002/(SICI)1099-1492(199606)9:4<156::AID-NBM412>3.0.CO
[3]  
2-B
[4]  
BROWN CEL, 1988, OBSTET GYNECOL, V71, P987
[5]   NMR CHEMICAL-SHIFT IMAGING IN 3 DIMENSIONS [J].
BROWN, TR ;
KINCAID, BM ;
UGURBIL, K .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1982, 79 (11) :3523-3526
[6]   VALIDATION AND APPLICATION OF DUAL-ENERGY X-RAY ABSORPTIOMETRY TO MEASURE BONE MASS AND BODY-COMPOSITION IN SMALL INFANTS [J].
BRUNTON, JA ;
BAYLEY, HS ;
ATKINSON, SA .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 58 (06) :839-845
[7]   Improvement in the accuracy of dual energy X-ray absorptiometry for whole body and regional analysis of body composition: Validation using piglets and methodologic considerations in infants [J].
Brunton, JA ;
Weiler, HA ;
Atkinson, SA .
PEDIATRIC RESEARCH, 1997, 41 (04) :590-596
[8]  
CHAN GM, 1992, J BONE MINER RES, V7, P369
[9]   A COMPARISON OF TOTAL-BODY WATER MEASUREMENTS USING WHOLE-BODY MAGNETIC-RESONANCE-IMAGING VERSUS TRITIUM DILUTION IN PRIMATES [J].
CHWALS, WJ ;
SOBOL, WT ;
CHARLES, BJ ;
HINSON, WH .
JOURNAL OF SURGICAL RESEARCH, 1992, 52 (04) :378-381
[10]   BODY-COMPOSITION ASSESSMENT [J].
DAVIES, PSW .