Using the slope-only technique and estimated glomerular filtration rate for checking the reliability of slope-intercept measurement of glomerular filtration rate

被引:8
作者
Bird, Nicholas J. [1 ]
Peters, Christina [1 ]
Michell, A. Robert [2 ]
Peters, A. Michael [1 ]
机构
[1] Addenbrookes Hosp, Dept Nucl Med, Cambridge CB2 2QQ, England
[2] St Bartholomews Med Sch, William Harvey Res Inst, Dept Biochem Pharmacol, London, England
关键词
Cr-51-ethylenediaminetetraacetic acid; glomerular filtration rate; iohexol; single sample; validation;
D O I
10.1097/MNM.0b013e328310b378
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim To develop a strategy for checking the reliability of slope intercept measurement of glomerular filtration rate (GFR). Methods Six blood samples, obtained bilaterally 20-240 min after the injection of Cr-51-ethylenediaminetetraacetic acid (EDTA) and iohexol into opposite arms, were assayed for indicator injected contralaterally. GFR6(iohexol), the reference value, was measured for all six samples and GFR3(EDTA) (slope-intercept) for the last three samples (per 1.73 m(2)). GFR was measured from the half-time [GFR/extracellular fluid volume (ECV)3(EDTA)], for the single samples at 2-4h (Christensen-Groth; GFR1) and for creatinine [estimated GFR (eGFR)]. Results In six of the 97 studies, the correlation coefficient W of the fit to the last three sample points was less than 0.99. In the remaining 91 studies, GFR3(EDTA) disagreed with GFR/ECVEDTA by more than 15% in 19 studies (group A) and by less than 15% in 72 studies (group 13). GFR3(EDTA) disagreed with GFR6(iohexol) by 12.6% in group A but only by 6.3% in group B (P < 0.001). No such discrimination was displayed by eGFR. Although GFR3(EDTA) was within 15% of GFR6(iohexol) in 14 group A studies, eGFR was within 15% of GFR3(EDTA) in only eight studies and disagreed by more than 15% in six studies. Conversely, in the five of the 19 studies in which GFR3(EDTA) disagreed with GFR6(iohexol) by more than 15%, the agreement between eGFR and GFR3(EDTA) Was less than 15% in two studies and more than 15% in three studies. GFR3(EDTA) was within 15% of GFR/ECV3(EDTA) in all six studies in which r was less than 0.99, and GFR3(EDTA) disagreed with GFR6(iohexol) by less than 15%. Confidence in GFR3(EDTA) was not improved by GFR1 or eGFR. Conclusion Slope intercept GFR is reliable if within 15% of GFR/ECV3. Estimated GFR was ineffective as a second checkpoint. GFR1 did not help when the fit was poor. Nucl Med Commun 29:1086-1092 (c) 2008 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:1086 / 1092
页数:7
相关论文
共 21 条
[1]   Reproducibilities and responses to food intake of GFR measured with chromium-51-EDTA and iohexol simultaneously and independently in normal subjects [J].
Bird, Nicholas J. ;
Peters, Christina ;
Michell, A. Robert ;
Peters, A. Michael .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2008, 23 (06) :1902-1909
[2]  
Bird NJ, 2003, J NUCL MED, V44, P1037
[3]  
BIRD NJ, 2008, SCAND J UROL NEPHROL, V14, P1
[4]   GFR measurement with iohexol and 51Cr-EDTA.: A comparison of the two favoured GFR markers in Europe [J].
Brandstrom, E ;
Grzegorczyk, A ;
Jacobsson, L ;
Friberg, P ;
Lindahl, A ;
Aurell, M .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 (05) :1176-1182
[6]  
BURNISTON MT, 2008, THESIS U LEEDS
[7]  
CHRISTENSEN AB, 1986, CLIN PHYSIOL, V6, P579
[8]   Relationship of gender, age, and body mass index to errors in predicted kidney function [J].
Cirillo, M ;
Anastasio, P ;
De Santo, NG .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2005, 20 (09) :1791-1798
[9]   Post-test quality control for the single blood sample technique in glomerular filtration rate measurement in children [J].
De Sadeleer, C ;
Piepsz, A ;
Ham, HR .
NUCLEAR MEDICINE COMMUNICATIONS, 2006, 27 (03) :255-260
[10]   A formula to estimate the approximate surface area if height and weight be known [J].
Du Bois, D ;
Du Bois, EF .
ARCHIVES OF INTERNAL MEDICINE, 1916, 17 (06) :863-871