The accuracy and external precision of isotope ratio measurements can be limited by any of a number of instrumental bias factors which include mass bias, pulse pile-up, background effects and mass scale shift. Measured isotope ratios are generally biased from their true value by the interaction of several of these instrumental bias factors. Attainment of accurate isotope ratio measurement requires careful consideration of all possible causes of instrumental bias and adoption of methods for their elimination or correction. The various forms of instrumental bias observed in measurement of the Pb isotope ratios for NIST SRM 981 Natural Lead (Isotopic) were minimised to reveal Pb-204:Pb-206 = 0.0592 +/- 0.0002, Pb-207:Pb-206 = 0.9148 +/- 0.0007 Pb-208:Pb-206 = 2.1709 +/- 0.0015 (n = 5) compared with certified values of 0.059042 +/- 0.000037, 0.91464 +/- 0.00033 and 2.1681 +/- 0.0008, respectively. The thallium mass bias concentration procedure was employed in obtaining this data. All uncertainties given as 2 sigma.
引用
收藏
页码:395 / 402
页数:8
相关论文
共 20 条
[1]  
BATEY J, COMMUNICATION
[2]   OCCURRENCE AND REDUCTION OF NOISE IN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY FOR ENHANCED PRECISION IN ISOTOPE RATIO MEASUREMENT [J].
BEGLEY, IS ;
SHARP, BL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (03) :171-176
[3]   QUANTITATIVE MEASUREMENTS WITH QUADRUPOLE MASS SPECTROMETERS - IMPORTANT SPECIFICATIONS FOR RELIABLE MEASUREMENTS [J].
BLEY, WG .
VACUUM, 1988, 38 (02) :103-109
[4]   DRIFT DIAGNOSTICS IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
CARRE, M ;
POUSSEL, E ;
MERMET, JM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (06) :791-797
[5]   DETERMINATION OF RARE-EARTH ELEMENTS IN GEOLOGICAL SAMPLES BY INDUCTIVELY COUPLED PLASMA SOURCE-MASS SPECTROMETRY [J].
DATE, AR ;
HUTCHISON, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (03) :269-276
[6]   ISOTOPE-DILUTION MASS-SPECTROMETRY FOR ACCURATE ELEMENTAL ANALYSIS [J].
FASSETT, JD ;
PAULSEN, PJ .
ANALYTICAL CHEMISTRY, 1989, 61 (10) :A643-&
[7]   NONSPECTROSCOPIC INTERELEMENT INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
GILLSON, GR ;
DOUGLAS, DJ ;
FULFORD, JE ;
HALLIGAN, KW ;
TANNER, SD .
ANALYTICAL CHEMISTRY, 1988, 60 (14) :1472-1474
[8]   NOISE IN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY - SOME PRELIMINARY MEASUREMENTS [J].
INCE, AT ;
WILLIAMS, JG ;
GRAY, AL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (06) :899-&
[9]   VERIFICATION OF A CORRECTION PROCEDURE FOR MEASUREMENT OF LEAD ISOTOPE RATIOS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
KETTERER, ME ;
PETERS, MJ ;
TISDALE, PJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (06) :439-443
[10]   ASSESSMENT OF OVERALL ACCURACY OF LEAD ISOTOPE RATIOS DETERMINED BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY USING BATCH QUALITY-CONTROL AND THE YOUDEN 2-SAMPLE METHOD [J].
KETTERER, ME .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (07) :1125-1129