Homogenization of breakfast cereals using cryogenic grinding

被引:24
作者
Gouveia, ST
Lopes, GS
Fatibello-Filho, O
Nogueira, ARA
Nóbrega, JA
机构
[1] Univ Fed Sao Carlos, Dept Quim, Grp Quim Analit, BR-13560970 Sao Carlos, SP, Brazil
[2] Univ Fed Ceara, Dept Quim Analit & Fis Quim, Fortaleza, Ceara, Brazil
[3] EMBRAPA, Ctr Pecuaria Sudeste, Empresa Brasileira Pesquisa Agropecuaria, Sao Carlos, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
sample preparation; cryogenic grinding; breakfast cereals;
D O I
10.1016/S0260-8774(01)00037-1
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Ready-to-eat breakfast cereals are important source of micronutrients despite the losses of these elements during processing. From an analytical point of view, these materials are complex heterogeneous samples containing as many as 13 constituents. It is critical that the sample be representative and grinding of the sample is essential before taking a sub-sample for subsequent steps in the analytical procedure. In this work the use of cryogenic grinding was studied as a fast and effective procedure for sample comminution and homogenization. This procedure is efficient and the powders obtained were acid-digested using a microwave-assisted procedure. Iron, manganese, and zinc were determined by flame atomic absorption spectrometry. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:59 / 63
页数:5
相关论文
共 10 条
[1]  
Booth Christine K., 1996, Journal of Food Composition and Analysis, V9, P135, DOI 10.1006/jfca.1996.0021
[2]  
DEBOER JLM, 1980, ANAL CHIM ACTA, V177, P371
[3]  
HOLLAND B, 1991, COMPOSITION FOODS, P308
[4]   APPLICATION OF BRITTLE-FRACTURE TECHNIQUE (BFT) TO HOMOGENISE BIOLOGICAL SAMPLES AND SOME OBSERVATIONS REGARDING DISTRIBUTION BEHAVIOR OF TRACE-ELEMENTS AT DIFFERENT CONCENTRATION LEVELS IN A BIOLOGICAL MATRIX [J].
IYENGAR, GV ;
KASPEREK, K .
JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1977, 39 (1-2) :301-316
[5]   THE DEVELOPMENT OF CRYO-GRINDING EQUIPMENT FOR THE TRANSFORMATION OF LARGE QUANTITIES OF BIOLOGICAL REFERENCE MATERIALS WITH LOW HEAVY-METAL CONTENTS [J].
KRAMER, GN ;
PAUWELS, J .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 338 (04) :390-393
[6]   Sample preparation (cleaning, drying, homogenization) for trace element analysis in plant matrices [J].
Markert, B .
SCIENCE OF THE TOTAL ENVIRONMENT, 1995, 176 (1-3) :45-61
[7]  
MAY TW, 1984, J ASSOC OFF ANA CHEM, V67, P589
[8]   Microhomogeneity of candidate reference materials: Comparison of solid sampling Zeeman-AAS with INAA [J].
Rossbach, M ;
Ostapczuk, P ;
Emons, H .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 360 (3-4) :380-383
[9]   Design of a cryogenic grinding system for spices [J].
Singh, KK ;
Goswami, TK .
JOURNAL OF FOOD ENGINEERING, 1999, 39 (04) :359-368
[10]   CRYOGENIC HOMOGENIZATION OF BIOLOGICAL TISSUES [J].
ZEISLER, R ;
LANGLAND, JK ;
HARRISON, SH .
ANALYTICAL CHEMISTRY, 1983, 55 (14) :2431-2434