Comparative study of five instruments measuring stratum corneum hydration (Corneometer CM 820 and CM 825, Skicon 200, Nova DPM 9003, DermaLab). Part II. In vivo

被引:69
作者
Fluhr, Joachim W. [1 ]
Gloor, Max [1 ]
Lazzerini, Sabrina [2 ]
Kleesz, Peter [3 ]
Grieshaber, Romano [3 ]
Berardesca, Enzo [2 ]
机构
[1] Stadt Klinikum Karlsruhe, Dept Dermatol, Moltkestr 120, D-76133 Karlsruhe, Germany
[2] Univ Pavia, ZRCCS, Policlin S Matteo, Dept Dermatol, Pavia, Italy
[3] BG Nahrungsmittel & Gaststatten, Res Ctr, Mannheim, Germany
关键词
bioengineering; capacitance; conductance; stratum corneum hydration; water holding capacity;
D O I
10.1111/j.1600-0846.1999.tb00127.x
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background/Aims: The hydration state of stratum corneum can be measured with different instruments. In the present study, five instruments were compared under different experimental in vivo conditions: Corneometer CM 820 and CM 825 (both capacitance based), Skicon 200 (conductance), Nova DPM (impedance based capacitance) and DermaLab (capacitance). Methods: Seven anatomical sites were tested, a sorption-desorption test (SDT) and a moisture accumulation test (MAT) were performed. Different hydration states were created on the volar forearms by occluded application of an oil-in-water (o/w) emulsion, glycerol and urea containing oil-in-water (o/w) emulsion, an untreated control site and a site after lipid extraction with acetone. Measurements were performed 15 min after removal of occlusion. Results: The coefficient of variation for CM 820 ranged between 9.3% and 23.7%; for CM 825 between 14.9% and 36.8%; for Skicon 200 between 53.0% and 167.3%; for Nova DPM between 36.4% and 95.8%; for DermaLab between 23.6% and 45.6%. All devices showed a highly significant correlation (P<0.0001) with a high Spearman coefficient r ranging between 0.7928 and 0.9358. Conclusions: CM 820 and CM 825 seem to differentiate more precisely than Nova DPM, Skicon 200 and DermaLab in dry conditions according to previous findings, i.e., that conductance measurements might be more sensitive for hydrated skin and capacitance measurements might be more sensitive for dry skin conditions. The CM 825, the Skicon 200 and the Nova DPM are suitable for dynamic measurements of hydration parameters of the stratum corneum.
引用
收藏
页码:171 / 178
页数:8
相关论文
共 24 条
[1]   SODIUM LAURYL SULFATE FOR IRRITANT PATCH TESTING - A DOSE-RESPONSE STUDY USING BIOENGINEERING METHODS FOR DETERMINATION OF SKIN IRRITATION [J].
AGNER, T ;
SERUP, J .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1990, 95 (05) :543-547
[2]  
Barel A O, 1997, Skin Res Technol, V3, P107, DOI 10.1111/j.1600-0846.1997.tb00171.x
[3]  
Berardesca E, 1997, Skin Res Technol, V3, P126, DOI 10.1111/j.1600-0846.1997.tb00174.x
[4]   Opposing effects of glycerol on the protective function of the horny layer against irritants and on the penetration of hexyl nicotinate [J].
Bettinger, J ;
Gloor, M ;
Peter, C ;
Kleesz, P ;
Fluhr, J ;
Gehring, W .
DERMATOLOGY, 1998, 197 (01) :18-24
[5]  
BLICHMANN CW, 1988, ACTA DERM-VENEREOL, V68, P284
[6]  
Fluhr J W, 1998, Z HAUTKRANKHEITEN, V73, P210
[7]  
FROEBE CL, 1990, J SOC COSMET CHEM, V41, P51
[8]  
GABARD B, 1994, BIOENGINEERING SKIN, P177
[9]  
Gehring W, 1998, KOSM MED, V19, P84
[10]  
Gloor M, 1998, HAUTARZT, V49, P6, DOI 10.1007/s001050050693