Inconsistent correlation between aerobic bacterial surface and air counts in operating rooms with ultra clean laminar air flows: proposal of a new bacteriological standard for surface contamination

被引:70
作者
Friberg, B
Friberg, S
Burman, LG
机构
[1] No Univ Hosp, Dept Orthopaed, S-90185 Umea, Sweden
[2] No Univ Hosp, Dept Clin Bacteriol, S-90185 Umea, Sweden
[3] No Univ Hosp, Dept Nursing, S-90185 Umea, Sweden
[4] Swedish Inst Infect Dis Control, S-10521 Stockholm, Sweden
关键词
operating rooms; ventilation; clothing; colony counts; microbiology;
D O I
10.1053/jhin.1998.0598
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The relationship between surface contamination (cfus/m(2)/h) with particles carrying aerobic bacteria and corresponding air contamination rates (cfus/m(3)) was evaluated in operating rooms (OR) equipped with ultra clean vertical or horizontal laminar airflow (LAF). For the evaluation we collected data during strictly standardized sham operations using non-woven disposable or cotton clothing. Air contamination in the wound and instrument areas (Casella slit sampler) was related to the surface contamination rate (settle plates) in the same areas and in addition, on the patient chest. Typically the mean surface counts were 20-70 cfus/m(2)/h and the air counts 1-2 cfus/m(3) in disposable clothing experiments, whilst the use of cotton clothing resulted in higher counts of 100-200 cfus/m(2)/h (wound P > 0.05, patient P>0.05, instruments P<0.01) and 4 cfus/m(3) (P<0.02-0.001). In the vertical LAF, taking both disposable and cotton clothing operations together, the surface and air contamination rates (surface/air ratio SAR) were highly correlated (P=0.02-0.004) and the ratio varied between 18:1 and 50:1 with a mean for wound air of 36:1. Using only disposable clothing in the vertical LAF, the number of significant correlations was reduced. With cotton clothing experiments in vertical LAF and in the horizontal LAF using disposable clothing, no significant correlation between surface and air contamination was found. The wide variation of SAR values and the inconsistent relationship between surface and air counts indicates that measurement of OR air contamination represents an unhelpful method for assessment of surgical site contamination in LAF units. We propose instead that colony counts on sedimentation plates is a clinically more relevant indicator of bacterial OR contamination in LAF units. In addition to the current bacteriological standard for ultra clean OR air of (<10 cfus/m(3)) we suggest a corresponding standard for the surface contamination rate of <350 cfus/m(2)/h.
引用
收藏
页码:287 / 293
页数:7
相关论文
共 14 条
[11]  
Whyte W, 1996, PDA J Pharm Sci Technol, V50, P201
[12]   THE RELATIVE IMPORTANCE OF THE ROUTES AND SOURCES OF WOUND CONTAMINATION DURING GENERAL-SURGERY .2. AIRBORNE [J].
WHYTE, W ;
HAMBRAEUS, A ;
LAURELL, G ;
HOBORN, J .
JOURNAL OF HOSPITAL INFECTION, 1992, 22 (01) :41-54
[13]  
WHYTE W, 1986, Journal of Parenteral Science and Technology, V40, P188
[14]   SUGGESTED BACTERIOLOGICAL STANDARDS FOR AIR IN ULTRACLEAN OPERATING-ROOMS [J].
WHYTE, W ;
LIDWELL, OM ;
LOWBURY, EJL ;
BLOWERS, R .
JOURNAL OF HOSPITAL INFECTION, 1983, 4 (02) :133-139