Human cerebral perfusion analysis with ultrasound contrast agent constant infusion: A pilot study on healthy volunteers

被引:32
作者
Seidel, G
Meyer, K
Metzler, V
Toth, D
Vida-Langwasser, M
Aach, T
机构
[1] Med Univ Lubeck, Dept Neurol, D-23538 Lubeck, Germany
[2] Med Univ Lubeck, Inst Signal Proc, D-23538 Lubeck, Germany
关键词
cerebrovascular circulation; contrast media; imaging; perfusion; ultrasonics;
D O I
10.1016/S0301-5629(01)00501-4
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
With ultrasound (US) contrast agent (UCA) continuous infusion providing a steady state, mean tissue microbubble velocity can be assessed by analyzing the reappearance rate after microbubble destruction with US energy (refill kinetics). In this study, we investigated this new approach for the assessment of human cerebral perfusion. A total of 12 healthy volunteers were investigated transtemporally with increasing pulsing intervals (250, 500, 750, 1000, 1250, 1500, 2000, 3000 and 4000 ms) and two UCA infusion rates (0.5 and 1.0 mL/min of Optison(TM))). Intensity vs. pulsing interval curves were analyzed using an exponential curve fit and parameters of the curve (plateau echo enhancement, A, representing the microbubble concentration within the interrogated tissue; rate constant, beta, which is related to blood flow and their product, F = Abeta) were compared. For 20/20 investigations being available for further analysis, it was possible to generate a typical exponential intensity vs. pulsing interval curve from the ipsilateral thalamus. The plateau echo enhancement A showed a significant (p = 0.02), and the beta as well as the F values displayed a nonsignificant (p = 0.06, both), increase with infusion rate. The qualitative analysis of beta and F parameter images displayed the most homogeneous visualisation of perfusion in the ipsilateral thalamus and main territory of the middle cerebral artery. In conclusion, it is possible to display the UCA refill kinetics in human cerebral microcirculation after microbubble destruction by transcranial US. Grey-scale harmonic imaging allows a quantitative approach to cerebral perfusion with a large interindividual variation of the parameters. (C) 2002 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:183 / 189
页数:7
相关论文
共 14 条
[1]  
DSA A, 1999, ACOUSTIC DENSITOMETR
[2]   Ultrasonic evaluation of pathological brain perfusion in acute stroke using second harmonic imaging [J].
Federlein, J ;
Postert, T ;
Meves, S ;
Weber, S ;
Przuntek, H ;
Büttner, T .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2000, 69 (05) :616-622
[3]   Pulse-inversion contrast harmonic imaging: ultrasonographic assessment of cerebral perfusion [J].
Meairs, S ;
Daffertshofer, M ;
Neff, W ;
Eschenfelder, C ;
Hennerici, M .
LANCET, 2000, 355 (9203) :550-551
[4]  
METZLER V, 2000, BILDVERARBEITUNG MED, P309
[5]   TRANSIENT MYOCARDIAL CONTRAST AFTER INITIAL EXPOSURE TO DIAGNOSTIC ULTRASOUND PRESSURES WITH MINUTE DOSES OF INTRAVENOUSLY INJECTED MICROBUBBLES - DEMONSTRATION AND POTENTIAL MECHANISMS [J].
PORTER, TR ;
XIE, F .
CIRCULATION, 1995, 92 (09) :2391-2395
[6]   Transient response harmonic imaging -: An ultrasound technique related to brain perfusion [J].
Postert, T ;
Muhs, A ;
Meves, S ;
Federlein, J ;
Przuntek, H ;
Büttner, T .
STROKE, 1998, 29 (09) :1901-1907
[7]   Second harmonic imaging in acute middle cerebral artery infarction -: Preliminary results [J].
Postert, T ;
Federlein, J ;
Weber, S ;
Przuntek, H ;
Büttner, T .
STROKE, 1999, 30 (08) :1702-1706
[8]   Contrast agent specific imaging modes for the ultrasonic assessment of parenchymal cerebral echo contrast enhancement [J].
Postert, T ;
Hoppe, P ;
Federlein, J ;
Helbeck, S ;
Ermert, H ;
Przuntek, H ;
Büttner, T ;
Wilkening, W .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2000, 20 (12) :1709-1716
[9]   Visualization of brain perfusion with harmonic gray scale and power Doppler technology - An animal pilot study [J].
Seidel, G ;
Algermissen, C ;
Christoph, A ;
Katzer, T ;
Kaps, M .
STROKE, 2000, 31 (07) :1728-1733
[10]   Harmonic grey scale imaging of the human brain [J].
Seidel, G ;
Greis, C ;
Sonne, J ;
Kaps, M .
JOURNAL OF NEUROIMAGING, 1999, 9 (03) :171-174