Contrast agent specific imaging modes for the ultrasonic assessment of parenchymal cerebral echo contrast enhancement

被引:50
作者
Postert, T
Hoppe, P
Federlein, J
Helbeck, S
Ermert, H
Przuntek, H
Büttner, T
Wilkening, W
机构
[1] Ruhr Univ Bochum, Dept Neurol, D-4630 Bochum, Germany
[2] Ruhr Univ Bochum, Dept Elect Engn, D-4630 Bochum, Germany
关键词
harmonic imaging; cerebral perfusion; stimulated acoustic emission; contrast burst imaging; time variance imaging; transcranial ultrasound; echo contrast agent;
D O I
10.1097/00004647-200012000-00010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Previous work has demonstrated that cerebral echo contrast enhancement can be assessed by means of transcranial ultrasound using transient response second harmonic imaging (HI). The current study was designed to explore possible advantages of two new contrast agent specific imaging modes, contrast burst imaging (CBI) and time variance imaging (TVI), that are based on the detection of destruction or splitting of microbubbles caused by ultrasound in comparison with contrast harmonic imaging (CHI), which is a broadband phase-inversion-based implementation of HI. Nine healthy individuals with adequate acoustic temporal bone windows were included in the study. Contrast harmonic imaging, CBI, and TVI examinations were performed in an axial diencephalic plane of section after an intravenous bolus injection of 4 g galactose-based microbubble suspension in a concentration of 400 mg/ mt. Using time-intensity curves, peak intensities and times-to peak-intensity (TPIs) were calculated off-line in anterior and posterior parts of the thalamus, in the region of the lentiform nucleus, and in the white matter. The potential of the different techniques to visualize cerebral contrast enhancement in different brain areas was compared. All techniques produced accurate cerebral contrast enhancement in the majority of investigated brain areas. Contrast harmonic imaging visualized signal increase in 28 of 36 regions of interest (ROIs). In comparison, TVI and CBI examinations were successful in 32 and 35 investigations, respectively. In CHI examinations, contrast enhancement was most difficult to visualize in posterior parts of the thalamus (6 of 9) and the lentiform nucleus (6 of 9). In TVI examinations, anterior parts of the thalamus showed signal increase in only 6 of 9 examinations. For all investigated imaging modes, PIs and TPIs in different ROIs did not differ significantly, except that TVI demonstrated significantly higher PIs in the lentiform nucleus as compared with the thalamus and the white matter (P < 0.05). The current study demonstrates for the first time that CBI and TVI represent new ultrasonic tools that allow noninvasive assessment of focal cerebral contrast enhancement and that CBI and TVI improve diagnostic sensitivity as compared with CHI.
引用
收藏
页码:1709 / 1716
页数:8
相关论文
共 26 条
[1]   Contrast-enhanced transcranial color-coded duplex sonography in ischemic cerebrovascular disease [J].
Baumgartner, RW ;
Arnold, M ;
Gonner, F ;
Staikow, I ;
Herrmann, C ;
Rivoir, A ;
Muri, RM .
STROKE, 1997, 28 (12) :2473-2478
[2]   Improved imaging of liver metastases with stimulated acoustic emission in the late phase of enhancement with the US contrast agent SH U 508A: Early experience [J].
Blomley, MJK ;
Albrecht, T ;
Cosgrove, DO ;
Patel, N ;
Jayaram, V ;
Butler-Barnes, J ;
Eckersley, RJ ;
Bauer, A ;
Schlief, R .
RADIOLOGY, 1999, 210 (02) :409-416
[3]   VASCULARIZATION OF PRIMARY CENTRAL-NERVOUS-SYSTEM TUMORS - DETECTION WITH CONTRAST-ENHANCED TRANSCRANIAL COLOR-CODED REAL-TIME SONOGRAPHY [J].
BOGDAHN, U ;
FROHLICH, T ;
BECKER, G ;
KRONE, A ;
SCHLIEF, R ;
SCHURMANN, J ;
JACHIMCZAK, P ;
HOFMANN, E ;
ROGGENDORF, W ;
ROOSEN, K .
RADIOLOGY, 1994, 192 (01) :141-148
[4]   TRANSCRANIAL COLOR-CODED REAL-TIME SONOGRAPHY IN ADULTS [J].
BOGDAHN, U ;
BECKER, G ;
WINKLER, J ;
GREINER, K ;
PEREZ, J ;
MEURERS, B .
STROKE, 1990, 21 (12) :1680-1688
[5]   BACKGROUND SUBTRACTION FROM TIME-INTENSITY CURVES IN VIDEODENSITOMETRY - A PITFALL IN FLOW ASSESSMENT USING CONTRAST ECHOCARDIOGRAPHY [J].
BOS, LJ ;
PIEK, JJ ;
SPAAN, JAE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (09) :1211-1218
[6]   Erosion of artificial endothelia in vitro by pulsed ultrasound:: Acoustic pressure, frequency, membrane orientation and microbubble contrast agent dependence [J].
Brayman, AA ;
Lizotte, LM ;
Miller, MW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (08) :1305-1320
[7]  
Burns PN, 1996, CLIN RADIOL, V51, P50
[8]   Contrast-enhanced transcranial color-coded duplex sonography - Efficiency and validity [J].
Gerriets, T ;
Seidel, G ;
Fiss, I ;
Modrau, B ;
Kaps, M .
NEUROLOGY, 1999, 52 (06) :1133-1137
[9]   Diagnostic impact and prognostic relevance of early contrast-enhanced transcranial color-coded duplex sonography in acute stroke [J].
Goertler, M ;
Kross, R ;
Baeumer, M ;
Jost, S ;
Grote, R ;
Weber, S ;
Wallesch, CW .
STROKE, 1998, 29 (05) :955-962
[10]   Evaluation of myocardial, hepatic, and renal perfusion in a variety of clinical conditions using an intravenous ultrasound contrast agent (Optison) and second harmonic imaging [J].
Hancock, J ;
Dittrich, H ;
Jewitt, DE ;
Monaghan, MJ .
HEART, 1999, 81 (06) :636-641