Contrast-enhanced transcranial color-coded duplex sonography - Efficiency and validity

被引:52
作者
Gerriets, T [1 ]
Seidel, G [1 ]
Fiss, I [1 ]
Modrau, B [1 ]
Kaps, M [1 ]
机构
[1] Univ Lubeck, Dept Neurol, Lubeck, Germany
关键词
D O I
10.1212/WNL.52.6.1133
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To evaluate the diagnostic efficiency and accuracy of contrast-enhanced transcranial color-coded sonography (CE-TCCS). Background: TCCS is hampered by insufficient ultrasonic penetration in 20% of cerebrovascular patients. Methods: In 47 patients whose basal arteries could not be assessed adequately, 59 TCCS examinations were performed before and after administration of the ultrasonic contrast agent (CA) Levovist. The assessability of different basal cerebral arteries after CA administration was evaluated off-line. Angiographic records were available from II patients. Results: Satisfactory investigation of the middle cerebral artery, the anterior cerebral artery, the P1 and P2 segments of the posterior cerebral artery, and the supraclinoid portion of the internal carotid artery siphon was possible in 5.1%, 28.8%, 35.6%, 55.9%, and 47.5% of patients before, and in 84.7%, 91.5%, 93.2%, 94.5%, and 93.2% of patients after contrast enhancement. Stenoses or occlusions of basal cerebral arteries were registered in 28 patients (60%). CE-TCCS diagnosis was confirmed by digital subtraction angiography or magnetic resonance angiography in 10 of the II patients, leading to positive and negative predictive values of 0.86 and 1.00. Conclusion: Contrast enhancement improves the diagnostic potential of TCCS significantly in patients with temporal bone window failure, and proved to be a reliable method for detecting middle cerebral artery and siphon occlusion.
引用
收藏
页码:1133 / 1137
页数:5
相关论文
共 20 条
[1]   HYPERDENSE MIDDLE CEREBRAL-ARTERY CT SIGN - COMPARISON WITH ANGIOGRAPHY IN THE ACUTE PHASE OF ISCHEMIC SUPRATENTORIAL INFARCTION [J].
BASTIANELLO, S ;
PIERALLINI, A ;
COLONNESE, C ;
BRUGHITTA, G ;
ANGELONI, U ;
ANTONELLI, M ;
FANTOZZI, LM ;
FIESCHI, C ;
BOZZAO, L .
NEURORADIOLOGY, 1991, 33 (03) :207-211
[2]   Contrast-enhanced transcranial color-coded duplex sonography in ischemic cerebrovascular disease [J].
Baumgartner, RW ;
Arnold, M ;
Gonner, F ;
Staikow, I ;
Herrmann, C ;
Rivoir, A ;
Muri, RM .
STROKE, 1997, 28 (12) :2473-2478
[3]   IMPROVED SENSITIVITY OF COLOR DOPPLER BY SH-U-454 [J].
BECHER, H ;
SCHLIEF, R .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 64 (05) :374-377
[4]   TRANSCRANIAL COLOR-CODED REAL-TIME SONOGRAPHY IN ADULTS .1. NORMAL FINDINGS AND CEREBRAL-ISCHEMIA [J].
BECKER, G ;
WINKLER, J ;
BOGDAHN, U .
ULTRASCHALL IN DER MEDIZIN, 1991, 12 (02) :74-79
[5]   CONTRAST-ENHANCED TRANSCRANIAL COLOR-CODED REAL-TIME SONOGRAPHY - RESULTS OF A PHASE-2 STUDY [J].
BOGDAHN, U ;
BECKER, G ;
SCHLIEF, R ;
REDDIG, J ;
HASSEL, W .
STROKE, 1993, 24 (05) :676-684
[6]  
DEBRAY JM, 1988, J ULTRAS MED, V7, P611
[7]   CT VISUALIZATION OF INTRACRANIAL ARTERIAL THROMBOEMBOLISM [J].
GACS, G ;
FOX, AJ ;
BARNETT, HJM ;
VINUELA, F .
STROKE, 1983, 14 (05) :756-762
[8]   GALACTOSE-BASED INTRAVENOUS SONOGRAPHIC CONTRAST AGENT - EXPERIMENTAL STUDIES [J].
GOLDBERG, BB ;
LIU, JB ;
BURNS, PN ;
MERTON, DA .
JOURNAL OF ULTRASOUND IN MEDICINE, 1993, 12 (08) :463-470
[9]   PERFUSION IMAGING OF THE BRAIN BY B-MODE ULTRASONOGRAPHY - AN EXPERIMENTAL-STUDY IN RABBITS [J].
ITOH, T ;
MATSUMOTO, M ;
UCHIMOTO, R ;
TAKAHASHI, N ;
NIWA, K ;
HANDA, N ;
TSUKAMOTO, Y ;
MIYAZAWA, T ;
KAMADA, T .
STROKE, 1995, 26 (12) :2353-2356
[10]   Comparison of transcranial color-coded sonography and magnetic resonance angiography in acute stroke [J].
Kenton, AR ;
Martin, PJ ;
Abbott, RJ ;
Moody, AR .
STROKE, 1997, 28 (08) :1601-1606