Survival of Mycobacterium avium in a model distribution system

被引:112
作者
Norton, CD
LeChevallier, MW
Falkinham, JO
机构
[1] Amer Water, Qual Control & Res Lab, Belleville, IL 62220 USA
[2] Amer Water, Corp Ctr, Voorhees, NJ 08043 USA
[3] Virginia Polytech Inst & State Univ, Fralin Biotechnol Ctr, Blacksburg, VA 24061 USA
关键词
Mycobacterium avium complex; biofilm; nutrient; disinfection; pipe material;
D O I
10.1016/j.watres.2003.07.008
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A pilot study was designed to examine the impact of nutrient levels, pipe materials, and disinfection on the survival of M. avium in model drinking water distribution system biofilms. Studies showed that the survival of the organism was dependant upon a complex interaction between pipe surface, nutrient levels, and disinfectants. The findings showed that when no disinfection was applied, M. avium could be recovered from biofilms at nutrient levels of 50 mug/L assimilable organic carbon. M. avium concentrations were lower on copper pipe surfaces following disinfection with free chlorine as compared to monochloramine. However, due to the interference of corrosion products, chloramination of iron pipe surfaces controlled M. avium levels better than free chlorine. These data demonstrate the significance of pipe materials on the survival of M. avium complex in biofilms. Elimination of competitive heterotrophic bacteria on copper pipe surfaces by the application of disinfection resulted in a population of nearly 100% M. avium. Heat treatment of M. avium biofilms was affected by the pipe composition and organic content of the water. Effluent temperatures > 53degreesC were required to control the occurrence of M. avium in the pipeline system. Although additional studies are required using improved detection methods, the results of this investigation suggest that reducing the biodegradable organic material in drinking water, control of corrosion, maintenance of an effective disinfectant residual, and management of hot water temperatures can help limit the occurrence of M. avium complex in drinking water biofilms. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1457 / 1466
页数:10
相关论文
共 28 条
[1]   Impairment of mycobacterial immunity in human interleukin-12 receptor deficiency [J].
Altare, F ;
Durandy, A ;
Lammas, D ;
Emile, JF ;
Lamhamedi, S ;
Le Deist, F ;
Drysdale, P ;
Jouanguy, E ;
Döffinger, R ;
Bernaudin, F ;
Jeppsson, O ;
Gollob, JA ;
Meinl, E ;
Segal, AW ;
Fischer, A ;
Kumararatne, D ;
Casanova, JL .
SCIENCE, 1998, 280 (5368) :1432-1435
[2]  
*AM PUBL HLTH ASS, 1995, STAND METH EX WAT WA
[3]  
CARSON LA, 1978, APPL ENVIRON MICROB, V36, P839, DOI 10.1128/AEM.36.6.839-846.1978
[4]   CONCENTRATION OF MYCOBACTERIUM-AVIUM BY HOSPITAL HOT WATER-SYSTEMS [J].
DUMOULIN, GC ;
STOTTMEIER, KD ;
PELLETIER, PA ;
TSANG, AY ;
HEDLEYWHYTE, J .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1988, 260 (11) :1599-1601
[5]   Factors influencing numbers of Mycobacterium avium, Mycobacterium intracellulare, and other mycobacteria in drinking water distribution systems [J].
Falkinham, JO ;
Norton, CD ;
LeChevallier, MW .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2001, 67 (03) :1225-1231
[6]  
FALKINHAM JO, 1980, AM REV RESPIR DIS, V121, P931
[7]  
GEORGE KL, 1980, AM REV RESPIR DIS, V122, P89
[8]  
Glover N., 1994, International Journal of Environmental Health Research, V4, P63, DOI 10.1080/09603129409356800
[9]  
Joret J. C., 1989, WATER SUPPLY, V7, P41
[10]   EPIDEMIOLOGY OF INFECTION BY NONTUBERCULOUS MYCOBACTERIA - MYCOBACTERIUM-AVIUM, MYCOBACTERIUM-INTRACELLULARE, AND MYCOBACTERIUM-SCROFULACEUM IN ACID, BROWN-WATER SWAMPS OF THE SOUTHEASTERN UNITED-STATES AND THEIR ASSOCIATION WITH ENVIRONMENTAL VARIABLES [J].
KIRSCHNER, RA ;
PARKER, BC ;
FALKINHAM, JO .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1992, 145 (02) :271-275