Single-shot diffusion MRI of human brain on a conventional clinical instrument

被引:41
作者
Liu, GY
vanGelderen, P
Duyn, J
Moonen, CTW
机构
[1] NIH,NATL CTR RES RESOURCES,BIOMED ENGN & INSTRUMENTAT PROGRAM,INVIVO NMR RES CTR,BETHESDA,MD 20892
[2] NIH,LAB DIAGNOST RADIOL RES,BETHESDA,MD 20892
关键词
diffusion; brain; single-shot MRI; gradient and spin echo (GRASE); Car-Purcell-Meiboom-Gill (CPMG);
D O I
10.1002/mrm.1910350508
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A single-shot diffusion MRI technique on a standard clinical 1.5T scanner is presented. The method incorporates the following elements: (a) an inversion RF pulse followed by a delay of 1.3 s to null cerebral spinal fluid (CSF) signal, (b) a stimulated echo sequence (TE = 56 ms, TM = 100 ms) to obtain strong diffusion weighting, (c) a single-shot gradient- and spin-echo (GRASE) sequence for imaging with a modified k-space trajectory and Carr-Purcell Meiboom-Gill (CPMG)-phase cycle. The trace of the diffusion coefficient obtained with this approach is in good agreement with values reported for animal brain, and for recent human studies. It is demonstrated that single-shot diffusion imaging of human brain is feasible on an unmodified standard instrument without high-gradient slew rate or extreme field homogeneity.
引用
收藏
页码:671 / 677
页数:7
相关论文
共 37 条
  • [21] DIFFUSION-WEIGHTED MR IMAGING OF ANISOTROPIC WATER DIFFUSION IN CAT CENTRAL-NERVOUS-SYSTEM
    MOSELEY, ME
    COHEN, Y
    KUCHARCZYK, J
    MINTOROVITCH, J
    ASGARI, HS
    WENDLAND, MF
    TSURUDA, J
    NORMAN, D
    [J]. RADIOLOGY, 1990, 176 (02) : 439 - 445
  • [22] EARLY DETECTION OF REGIONAL CEREBRAL-ISCHEMIA IN CATS - COMPARISON OF DIFFUSION-WEIGHTED AND T2-WEIGHTED MRI AND SPECTROSCOPY
    MOSELEY, ME
    COHEN, Y
    MINTOROVITCH, J
    CHILEUITT, L
    SHIMIZU, H
    KUCHARCZYK, J
    WENDLAND, MF
    WEINSTEIN, PR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) : 330 - 346
  • [23] O'Donnell M, 1985, Magn Reson Imaging, V3, P377, DOI 10.1016/0730-725X(85)90401-1
  • [24] CORRECTION OF MOTIONAL ARTIFACTS IN DIFFUSION-WEIGHTED MR-IMAGES USING NAVIGATOR ECHOES
    ORDIDGE, RJ
    HELPERN, JA
    QING, ZX
    KNIGHT, RA
    NAGESH, V
    [J]. MAGNETIC RESONANCE IMAGING, 1994, 12 (03) : 455 - 460
  • [25] GRASE (GRADIENT-ECHO AND SPIN-ECHO) IMAGING - A NOVEL FAST MRI TECHNIQUE
    OSHIO, K
    FEINBERG, DA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 20 (02) : 344 - 349
  • [26] SINGLE-SHOT GRASE IMAGING WITHOUT FAST GRADIENTS
    OSHIO, K
    FEINBERG, DA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 26 (02) : 355 - 360
  • [27] SPIN DIFFUSION MEASUREMENTS: SPIN ECHOES IN THE PRESENCE OF A TIME-DEPENDENT FIELD GRADIENT
    STEJSKAL, EO
    TANNER, JE
    [J]. JOURNAL OF CHEMICAL PHYSICS, 1965, 42 (01) : 288 - +
  • [28] DIFFERENTIATION OF CHRONIC LESIONS AFTER STROKE IN STROKE-PRONE SPONTANEOUSLY HYPERTENSIVE RATS USING DIFFUSION-WEIGHTED MRI
    TAKAHASHI, M
    FRITZZIEROTH, B
    CHIKUGO, T
    OGAWA, H
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (04) : 485 - 488
  • [29] USE OF STIMULATED ECHO IN NMR-DIFFUSION STUDIES
    TANNER, JE
    [J]. JOURNAL OF CHEMICAL PHYSICS, 1970, 52 (05) : 2523 - &
  • [30] THE SPATIAL-MAPPING OF TRANSLATIONAL DIFFUSION-COEFFICIENTS BY THE NMR IMAGING TECHNIQUE
    TAYLOR, DG
    BUSHELL, MC
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (04) : 345 - 349