Hybrid alumina total hip arthroplasty using a press-fit metal-backed socket in patients younger than 55 years - A six- to 11-year evaluation

被引:74
作者
Bizot, P [1 ]
Hannouche, D [1 ]
Nizard, R [1 ]
Witvoet, J [1 ]
Sedel, L [1 ]
机构
[1] Univ Paris 07, Dept Orthopaed Surg, Lariboisiere Hosp, F-75475 Paris 10, France
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2004年 / 86B卷 / 02期
关键词
D O I
10.1302/0301-620X.86B2.14026
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Between 1990 and 1992, we implanted 71 hybrid alumina-on-alumina hip arthroplasties in 62 consecutive patients; under the age of 55 years, with a mean age of 46 years at surgery. There were 56 primary and 15 secondary procedures. The prostheses involved a cemented titanium alloy stem, a 32 mm alumina head, and a press-fit metal-backed socket with an alumina insert. Three patients (four hips) died from unrelated causes. Four hips had revision surgery for either deep infection, unexplained persistent pain, fracture of the alumina head, or aseptic loosening of the socket. The nine-year survival rate was 93.7% with revision for any cause as the end-point and 98.4% with revision for aseptic loosening as the end-point. The outcome in the surviving patients (50 patients, 57 hips) with a minimum five-year follow-up (mean eight years) was excellent in 47 hips (82.5%), very good in eight (14%), good in one and fair in one. A thin, partial, lucent line, mainly in zone III was present in 38% of the sockets and one socket had a complete lucency less than 1mm thick. One stem had isolated femoral osteolysis. There was no detectable component migration nor acetabular osteolysis. This hybrid arthroplasty gave satisfactory medium-term results in active patients. The press-fit metal-backed socket appeared to have reliable fixation in alumina-on-alumina hip arthroplasty. The excellent results using cemented fixation of the stem may be related to the low production of wear debris.
引用
收藏
页码:190 / 194
页数:5
相关论文
共 41 条
[1]
[Anonymous], 1979, CLIN ORTHOP RELAT RE
[2]
ARMITAGE P, 1994, STAT METHODS MED RES, P469
[3]
BALLARD WT, 1994, J BONE JOINT SURG AM, V76A, P959
[4]
BERGER RA, 1996, CLIN ORTHOP RELAT R, V333, P134
[5]
Tissue response to porous tantalum acetabular cups - A canine model [J].
Bobyn, JD ;
Toh, KK ;
Hacking, SA ;
Tanzer, M ;
Krygier, JJ .
JOURNAL OF ARTHROPLASTY, 1999, 14 (03) :347-354
[6]
LONG-TERM RESULTS OF UNCEMENTED ALUMINA ACETABULAR IMPLANTS [J].
BOEHLER, M ;
KNAHR, K ;
PLENK, H ;
WALTER, A ;
SALZER, M ;
SCHREIBER, V .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (01) :53-59
[7]
OSTEOLYSIS AFTER CERAMIC-ON-CERAMIC HIP-ARTHROPLASTY - A CASE-REPORT [J].
BORSSEN, B ;
KARRHOLM, J ;
SNORRASON, F .
ACTA ORTHOPAEDICA SCANDINAVICA, 1991, 62 (01) :73-75
[8]
Morphologic characteristics of periprosthetic tissues from hip prostheses with ceramic-ceramic couples - A comparative histologic investigation of 18 revision and 30 autopsy cases [J].
Bos, I ;
Willmann, G .
ACTA ORTHOPAEDICA SCANDINAVICA, 2001, 72 (04) :335-342
[9]
Charnley total hip arthroplasty in patients less than fifty years old - A twenty to twenty-five-year follow-up note [J].
Callaghan, JJ ;
Forest, EE ;
Olejniczak, JP ;
Goetz, DD ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (05) :704-714
[10]
TOTAL HIP-REPLACEMENT IN PATIENTS YOUNGER THAN 30 YEARS OLD - A 5-YEAR FOLLOW-UP-STUDY [J].
CHANDLER, HP ;
REINECK, FT ;
WIXSON, RL ;
MCCARTHY, JC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1981, 63 (09) :1426-1434