Trace analysis of bromate and bromide with ion chromatography on coated reversed phase materials

被引:15
作者
Bohme, U
Schmidt, W
Dietrich, PG
Matschi, A
Sacher, F
Brauch, HJ
机构
[1] DVGW TECHNOL ZENTRUM WASSER,AUSSENSTELLE DRESDEN,D-01139 DRESDEN,GERMANY
[2] AUF GMBH,D-1284 BERLIN,GERMANY
[3] DVGW TECHNOL ZENTRUM WASSER,D-76139 KARLSRUHE,GERMANY
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1997年 / 357卷 / 06期
关键词
D O I
10.1007/s002160050225
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The ion-chromatographic method for trace analysis of bromate and bromide presented in this paper is based on coating of reversed phase (RP) material with an ionogenic agent, tetrakisdecylammonium bromide, to obtain a pseudo ion-exchange column. The analysis is carried out with usual HPLC pump and UV-detection near 200 nm. Some commercially available RP materials were tested for the coating procedure. The differences between the reversed phases are not significant. All HETP values are calculated between 0.02 and 0.14 mm. The calibration, the sensitivity of the method and the long-time stability of the coated column were tested with one selected RP material. It is shown that the simultaneous trace analysis of bromate and bromide in surface and drinking waters with chloride concentrations up to 50 mg/L is possible without any clean-up on Ag precolumns. A comparison of performance data with a determination method for bromate and bromide employing a commercially available equipment demonstrates the efficiency of the new technique.
引用
收藏
页码:629 / 634
页数:6
相关论文
共 15 条
[1]   DYNAMIC AND FIXED-SITE ION-EXCHANGE COLUMNS WITH CONDUCTOMETRIC DETECTION FOR THE SEPARATION OF INORGANIC ANIONS [J].
CASSIDY, RM ;
ELCHUK, S .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1983, 21 (10) :454-459
[2]  
Commission of the European Communities, 1994, PROP COUNC DIR QUAL
[3]   OZONATION OF BROMIDE-CONTAINING WATERS - KINETICS OF FORMATION OF HYPOBROMOUS ACID AND BROMATE [J].
HAAG, WR ;
HOIGNE, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1983, 17 (05) :261-267
[4]   ANALYSIS OF OXYHALIDE DISINFECTION BY-PRODUCTS AND OTHER ANIONS OF INTEREST IN DRINKING-WATER BY ION CHROMATOGRAPHY [J].
HAUTMAN, DP ;
BOLYARD, M .
JOURNAL OF CHROMATOGRAPHY, 1992, 602 (1-2) :65-74
[5]   TRACE-LEVEL DETERMINATION OF BROMATE IN OZONATED DRINKING-WATER USING ION CHROMATOGRAPHY [J].
JOYCE, RJ ;
DHILLON, HS .
JOURNAL OF CHROMATOGRAPHY A, 1994, 671 (1-2) :165-171
[6]  
KRUITHOF JC, 1992, WATER SUPPLY, V11, P121
[7]   TOXICITY AND CARCINOGENICITY OF POTASSIUM BROMATE - A NEW RENAL CARCINOGEN [J].
KUROKAWA, Y ;
MAEKAWA, A ;
TAKAHASHI, M ;
HAYASHI, Y .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1990, 87 :309-335
[8]  
KUROKAWA Y, 1982, JPN J CANCER RES, V73, P335
[9]   EVALUATION OF GENOTOXICITY OF BROMATE ION PRODUCED DURING OZONATION [J].
ONO, Y ;
SOMIYA, I ;
MOHRI, S .
OZONE-SCIENCE & ENGINEERING, 1994, 16 (05) :443-453
[10]   ANALYSIS AND OCCURRENCE OF BROMATE IN RAW WATER AND DRINKING-WATER [J].
SACHER, F ;
MATSCHI, A ;
BRAUCH, HJ .
ACTA HYDROCHIMICA ET HYDROBIOLOGICA, 1995, 23 (01) :26-30