Development of an amperometric enzymatic biosensor based on gold modified magnetic nanoporous microparticles

被引:38
作者
Elyacoubi, A [1 ]
Zayed, SIM [1 ]
Blankert, B [1 ]
Kauffmann, JM [1 ]
机构
[1] Univ Libre Bruxelles, Inst Pharm, B-1050 Brussels, Belgium
关键词
amperometric enzymatic biosensor; magnetic nanoporous microparticles; enzyme horseradish peroxidase (HRP); hydroquinone (HQ);
D O I
10.1002/elan.200503418
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gold modified nanoporous silica based magnetic microparticles have been prepared as support for the immobilization of the enzyme horseradish peroxidase (HRP). The enzyme modified gold microparticles were retained onto the surface of a solid carbon paste electrode with the help of a permanent magnet. ne analytical performances of the resulting biosensor were characterized by studying hydroquinone (HQ) and hydrogen peroxide. The former was monitored by the direct electroreduction of the biocatalytically generated quinone. Several experimental parameters influencing the biosensor response were investigated. A linear response to HQ was obtained in the concentration range comprised between 5 X 10(-7) and 4.5 x 10(-6) M with a detection limit of 4 x 10(-7) M. The enzyme electrode provided a linear response to hydrogen peroxide over a concentration range comprised between 5 x to(-7) - 1.3 x 10(-4) M with a detection limit of 4 x 10(-7) M. The inhibition of the biosensor response in the presence of thiols e.g. cysteine, captopril, glutathione and Nacystelyn (NAL) has been pointed out.
引用
收藏
页码:345 / 350
页数:6
相关论文
共 37 条
[1]   Novel separation and preconcentration of trace amounts of copper(II) in water samples based on neocuproine modified magnetic microparticles [J].
Ashtari, P ;
Wang, KM ;
Yang, XH ;
Huang, SS ;
Yamini, Y .
ANALYTICA CHIMICA ACTA, 2005, 550 (1-2) :18-23
[2]  
BORCH RF, 1971, J AM CHEM SOC, V93, P28970
[3]   A disposable immunomagnetic electrochemical sensor based on functionalised magnetic beads and carbon-based screen-printed electrodes (SPCEs) for the detection of polychlorinated biphenyls (PCBs) [J].
Centi, S ;
Laschi, S ;
Fránek, M ;
Mascini, M .
ANALYTICA CHIMICA ACTA, 2005, 538 (1-2) :205-212
[4]   An integrated microfluidic biochemical detection system for protein analysis with magnetic bead-based sampling capabilities [J].
Choi, JW ;
Oh, KW ;
Thomas, JH ;
Heineman, WR ;
Halsall, HB ;
Nevin, JH ;
Helmicki, AJ ;
Henderson, HT ;
Ahn, CH .
LAB ON A CHIP, 2002, 2 (01) :27-30
[5]   Functionalized nanoporous silicas for the immobilization of penicillin acylase [J].
Chong, ASM ;
Zhao, XS .
APPLIED SURFACE SCIENCE, 2004, 237 (1-4) :398-404
[6]  
DEY PM, 1984, EUR J BIOCHEM, V385, P140
[7]   Enzyme immobilization in MCM-41 molecular sieve [J].
Diaz, JF ;
Balkus, KJ .
JOURNAL OF MOLECULAR CATALYSIS B-ENZYMATIC, 1996, 2 (2-3) :115-126
[8]   Flow-based microimmunoassay [J].
Hayes, MA ;
Polson, NA ;
Phayre, AN ;
Garcia, AA .
ANALYTICAL CHEMISTRY, 2001, 73 (24) :5896-5902
[9]   Morphologic evolution and optical properties of nanostructured gold based on mesoporous silica [J].
Kan, CX ;
Cai, WP ;
Li, CC ;
Fu, GH ;
Zhang, LD .
JOURNAL OF APPLIED PHYSICS, 2004, 96 (10) :5727-5734
[10]   Enhancement of bioelectrocatalytic processes by the rotation of mediator-functionalized magnetic particles on electrode surfaces: Comparison with a rotating disk electrode [J].
Katz, E ;
Willner, I .
ELECTROANALYSIS, 2005, 17 (18) :1616-1626