The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures

被引:154
作者
Bai, B [1 ]
Jazrawi, LM [1 ]
Kummer, FJ [1 ]
Spivak, JM [1 ]
机构
[1] Hosp Joint Dis & Med Ctr, Inst Orthopaed, Dept Orthopaed Surg, Musculoskeletal Res Ctr, New York, NY 10003 USA
关键词
bone substitute; fracture; osteoporosis; spine; vertebra;
D O I
10.1097/00007632-199908010-00004
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A biomechanical study comparing two materials for augmentation of osteoporotic vertebral bodies and vertebral bodies after compression fracture. Objectives. To compare an injected, biodegradable calcium phosphate bone substitute with injected polymethylmethacrylate bone cement for Strengthening osteoporotic vertebral bodies and improving the integrity of vertebral compression fractures. Summary of Background Data. Injection of polymethylmethacrylate bone cement into fractured vertebral bodies has been used clinically. However, there is concern about thermal damage to the neural elements during polymerization of the polymethylmethacrylate bone cement as well as its negative effects on bone remodeling. Biodegradable calcium phosphate bone substitutes have been studied for enhancement of fixation in fractured vertebrae. Methods. Forty fresh osteoporotic thoracolumbar vertebrae were used for two separate parts of this study: 1) injection into osteoporotic vertebrae: intact control (n = 8), calcium phosphate (n = 8), and polymethylmethacrylate bone cement in = 8) groups. Each specimen then was loaded in anterior compression until failure; 2) injection into postfractured vertebrae: calcium phosphate in = 8) and polymethylmethacrylate bone cement (n = 8) groups. Before and after injection, the specimens were radiographed in the lateral projection to determine changes in vertebral body height and then loaded to failure in anterior bending. Results. For intact osteoporotic vertebrae, the average fracture strength was 527 +/- 43 N (stiffness, 84 +/- 11 N/mm), 1063 +/- 127 N (stiffness, 157 +/- 21 N/mm) for the group injected with calcium phosphate, and 1036 +/- 100 N (stiffness, 156 +/- 8 N/mm) for the group injected With polymethylmethacrylate bone cement. The fracture strength and stiffness in the calcium phosphate bone substitute group and those in the polymethylmethacrylate bone cement group were similar and significantly stronger than those in intact control group (P < 0.05). For the compression fracture study, anterior vertebral height was increased 58.5 +/- 4.6% in the group injected with calcium phosphate and 58.0 +/- 6.5% in the group injected with polymethylmethacrylate bone cement as compared with preinjection fracture heights. Nd significant difference between the two groups was found in anterior vertebral height, fracture strength, or stiffness. Conclusion. This study demonstrated that the injection of a biodegradable calcium phosphate bone substitute to strengthen osteoporotic vertebral bodies or improve vertebra compression fractures might provide a n alternative to the use of polymethylmethacrylate bone cement.
引用
收藏
页码:1521 / 1526
页数:6
相关论文
共 37 条
  • [31] EPIDEMIOLOGY OF VERTEBRAL FRACTURES IN WOMEN
    MELTON, LJ
    KAN, SH
    FRYE, MA
    WAHNER, HW
    OFALLON, WM
    RIGGS, BL
    [J]. AMERICAN JOURNAL OF EPIDEMIOLOGY, 1989, 129 (05) : 1000 - 1011
  • [32] Reinforcement of thoracolumbar burst fractures with calcium phosphate cement - A biomechanical study
    Mermelstein, LE
    McLain, RF
    Yerby, SA
    [J]. SPINE, 1998, 23 (06) : 664 - 670
  • [33] FAILURE LOAD OF THORACIC VERTEBRAE CORRELATES WITH LUMBAR BONE-MINERAL DENSITY MEASURED BY DXA
    MORO, M
    HECKER, AT
    BOUXSEIN, ML
    MYERS, ER
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (03) : 206 - 209
  • [34] CARDIOVASCULAR EFFECTS OF IMPLANTED ACRYLIC BONE CEMENT
    PHILLIPS, H
    COLE, PV
    LETTIN, AWF
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 1971, 3 (5772): : 460 - +
  • [35] ROLE OF TRABECULAR MORPHOLOGY IN THE ETIOLOGY OF AGE-RELATED VERTEBRAL FRACTURES
    SNYDER, BD
    PIAZZA, S
    EDWARDS, WT
    HAYES, WC
    SCHAFFLER
    ROSS
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1993, 53 : S14 - S22
  • [36] Spinal metastases: Indications for and results of percutaneous injection of acrylic surgical cement
    Weill, A
    Chiras, J
    Simon, JM
    Rose, M
    SolaMartinez, T
    Enkaoua, E
    [J]. RADIOLOGY, 1996, 199 (01) : 241 - 247
  • [37] NEUROLOGICAL DETERIORATION AFTER CEMENT INJECTION INTO A VERTEBRAL BODY
    WILKES, RA
    MACKINNON, JG
    THOMAS, WG
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (01): : 155 - 155