Spline surface interpolation for calculating 3-D ventricular strains from MRI tissue tagging

被引:56
作者
Moulton, MJ
Creswell, LL
Downing, SW
Actis, RL
Szabo, BA
Vannier, MW
Pasque, MK
机构
[1] WASHINGTON UNIV, DIV CARDIOTHORAC SURG, ST LOUIS, MO 63110 USA
[2] WASHINGTON UNIV, DEPT SURG, ST LOUIS, MO 63110 USA
[3] WASHINGTON UNIV, DEPT MECH ENGN, ST LOUIS, MO 63110 USA
[4] WASHINGTON UNIV, MALLINCKRODT INST RADIOL, ST LOUIS, MO USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 1996年 / 270卷 / 01期
关键词
mathematical modeling; cardiac mechanics; magnetic resonance imaging tissue tagging;
D O I
10.1152/ajpheart.1996.270.1.H281
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A method is developed and validated for approximating continuous smooth distributions of finite strains in the ventricles from the deformations of magnetic resonance imaging (MRI) tissue tagging "tag lines" or "tag surfaces." Tag lines and intersections of orthogonal tag lines are determined using a semiautomated algorithm. Three-dimensional (3-D) reconstruction of the displacement field on tag surfaces is performed using two orthogonal sets of MRI images and employing spline surface interpolation. The 3-D regional ventricular wall strains are computed from an initial reference image to a deformed image in diastole or systole by defining a mapping or transformation of space between the two states. The resultant mapping is termed the measurement analysis solution and is defined by determining a set of coefficients for the approximating functions that best fit the measured tag surface displacements. Validation of the method is performed by simulating tag line or surface deformations with a finite element (FE) elasticity solution of the heart and incorporating the measured root-mean-square (rms) errors of tag line detection into the simulations. The FE-computed strains are compared with strains calculated by the proposed procedure. The average difference between two-dimensional (2-D) FE-computed strains and strains calculated by the measurement analysis was 0.022 +/- 0.009 or 14.2 +/- 3.6% of the average FE elasticity strain solution. The 3-D displacement reconstruction errors averaged 0.087 +/- 0.002 mm or 2.4 +/- 0.1% of the average FE solution, and 3-D strain fitting errors averaged 0.024 +/- 0.011 or 15.9 +/- 2.8% of the average 3-D FE elasticity solution. When the rms errors in tag line detection were included in the 2-D simulations, the agreement between FE solution and fitted solution was 24.7% for the 2-D simulations and 19.2% for the 3-D simulations. We conclude that the 3-D displacements of MRI tag lines may be reconstructed accurately; however, the strain solution magnifies the small errors in locating tag lines and reconstructing 3-D displacements.
引用
收藏
页码:H281 / H297
页数:17
相关论文
共 32 条
  • [21] ODELL WG, 1993, J MAGNET RESON IMAG, V3, P143
  • [22] OMENS JH, 1991, AM J PHYSIOL, V261, pH919
  • [23] PRESSURE-GATED ACQUISITION OF CARDIAC MR IMAGES
    PIROLO, JS
    BRANHAM, BH
    CRESWELL, LL
    PERMAN, WH
    VANNIER, MW
    PASQUE, MK
    [J]. RADIOLOGY, 1992, 183 (02) : 487 - 492
  • [24] Press W. H., 1988, numerical recipes in c
  • [25] Szabo B., 1991, Finite Element Analysis
  • [26] REGULARIZATION OF INVERSE VISUAL PROBLEMS INVOLVING DISCONTINUITIES
    TERZOPOULOS, D
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1986, 8 (04) : 413 - 424
  • [27] RELATION BETWEEN TRANSMURAL DEFORMATION AND LOCAL MYOFIBER DIRECTION IN CANINE LEFT-VENTRICLE
    WALDMAN, LK
    NOSAN, D
    VILLARREAL, F
    COVELL, JW
    [J]. CIRCULATION RESEARCH, 1988, 63 (03) : 550 - 562
  • [28] EPICARDIAL SURFACE ESTIMATION FROM CORONARY ANGIOGRAMS
    YOUNG, AA
    HUNTER, PJ
    SMAILL, BH
    [J]. COMPUTER VISION GRAPHICS AND IMAGE PROCESSING, 1989, 47 (01): : 111 - 127
  • [29] VALIDATION OF TAGGING WITH MR-IMAGING TO ESTIMATE MATERIAL DEFORMATION
    YOUNG, AA
    AXEL, L
    DOUGHERTY, L
    BOGEN, DK
    PARENTEAU, CS
    [J]. RADIOLOGY, 1993, 188 (01) : 101 - 108
  • [30] 3-DIMENSIONAL MOTION AND DEFORMATION OF THE HEART WALL - ESTIMATION WITH SPATIAL MODULATION OF MAGNETIZATION - A MODEL-BASED APPROACH
    YOUNG, AA
    AXEL, L
    [J]. RADIOLOGY, 1992, 185 (01) : 241 - 247