Membrane desolvation for the analysis of organic solutions and liquid chromatographic samples with low power helium microwave induced plasma atomic emission detection

被引:15
作者
Akinbo, OT [1 ]
Carnahan, JW [1 ]
机构
[1] No Illinois Univ, Dept Chem & Biochem, De Kalb, IL 60115 USA
关键词
membrane desolvator; desolvation; helium microwave induced plasma; liquid chromatography; atomic emission detector; atomic emission spectroscopy;
D O I
10.1016/S0003-2670(99)00169-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flat sheet membrane desolvator (FSMD) was used to extend the applicability of a 120 W helium microwave induced plasma (He-MIP) to elemental analysis of organic-solvent-based samples and element selective liquid chromatographic detection. With the FSMD on-line, methanol could be nebulized with a sample flow rate of 1.5 ml/min and a carrier gas flow rate of 1.2 l/min without extinguishing the plasma. Under these conditions, applying desolvator countercurrent gas flows in the range 0-8 l/min restored of the original pink color of the pure helium MIP from the bluish-green caused by methanol. Significant reductions in the emission intensities of C-2 species at 436.5, 473.7, 512.9, and 563.6 nm were observed with the application of the FSMD. The intensities of chlorine analyte emission lines at 479.5, 481.0 and 481.9 nm increased with increasing countercurrent gas flow rates and reached a maximum intensity with a flow rate of 5.0 l/min. Detection limits for Cl and Pb were 2.1 and 0.1 ppm using a 1 m focal length monochromator. Other elements and solvent combinations were also examined. Element selective liquid chromatographic detection was preliminarily examined by monitoring 2,6-dichlorobenzene and 5,7-dichlorohydroxyquinoline at the 479.5 nm Cl atomic emission line. Chlorine detection limits in the 3-7 mu g range (70-190 ng/s) were obtained. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:217 / 226
页数:10
相关论文
共 44 条
[21]   SIZE EXCLUSION CHROMATOGRAPHY OF ORGANICALLY BOUND METALS AND COAL-DERIVED MATERIALS WITH INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRIC DETECTION [J].
HAUSLER, DW ;
TAYLOR, LT .
ANALYTICAL CHEMISTRY, 1981, 53 (08) :1227-1231
[22]  
HILL JS, 1992, J ANAL ATOM SPECTROM, V7, P23
[23]   INDUCTIVELY COUPLED ARGON PLASMA AS AN ION-SOURCE FOR MASS-SPECTROMETRIC DETERMINATION OF TRACE-ELEMENTS [J].
HOUK, RS ;
FASSEL, VA ;
FLESCH, GD ;
SVEC, HJ ;
GRAY, AL ;
TAYLOR, CE .
ANALYTICAL CHEMISTRY, 1980, 52 (14) :2283-2289
[24]   ROLE OF AEROSOL WATER-VAPOR LOADING IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
HUTTON, RC ;
EATON, AN .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (06) :595-598
[25]   HYDRAULIC HIGH-PRESSURE NEBULIZATION - APPLICATION OF A NEW NEBULIZATION SYSTEM FOR INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
JAKUBOWSKI, N ;
FELDMANN, I ;
STUEWER, D ;
BERNDT, H .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (01) :119-129
[26]   THERMOSPRAY SAMPLE INTRODUCTION TO ATOMIC SPECTROMETRY [J].
KOROPCHAK, JA ;
VEBER, M .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1992, 23 (03) :113-141
[27]   EFFECTS OF THE SOLVENT PLASMA LOAD OF VARIOUS SOLVENTS ON THE EXCITATION CONDITIONS IN MEDIUM POWER INDUCTIVELY COUPLED PLASMAS [J].
KREUNING, G ;
MAESSEN, FJMJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1989, 44 (04) :367-384
[28]   USE OF AEROSOL PROCESSING AND NITROGEN - ARGON PLASMAS FOR REDUCTION OF OXIDE INTERFERENCE IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
LAM, JW ;
MCLAREN, JW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (06) :419-424
[29]   EXPERIMENTAL CONTROL OF THE SOLVENT LOAD OF INDUCTIVELY COUPLED ARGON PLASMAS AND EFFECTS OF THE CHLOROFORM PLASMA LOAD ON THEIR ANALYTICAL PERFORMANCE [J].
MAESSEN, FJMJ ;
KREUNING, G ;
BALKE, J .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1986, 41 (1-2) :3-25
[30]   ANALYTICAL ASPECTS OF ORGANIC-SOLVENT LOAD REDUCTION IN NORMAL-POWER ICPS BY AEROSOL THERMOSTATTING AT LOW-TEMPERATURES [J].
MAESSEN, FJMJ ;
SEEVERENS, PJH ;
KREUNING, G .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1984, 39 (9-11) :1171-1180