Array detection for speckle reduction in optical coherence microscopy

被引:122
作者
Schmitt, JM
机构
[1] Dept. of Elec. and Electron. Eng., Hong Kong Univ. of Sci. and Technol., Kowloon, Clear Water Bay
关键词
D O I
10.1088/0031-9155/42/7/015
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper introduces a spatial-diversity method for speckle suppression in optical coherence microscopy. The method is based on combining interference signals from an array of detectors placed in the back focal plane of the objective lens, such that elements receive light backscattered from the sample volume at different angles. Incoherently adding ('compounding') the signals increases the signal-to-noise ratio of the processed image compared to that attainable with a single detector. The speckle-reduction method was demonstrated with a benchtop microscope equipped with a quadrant photodiode. To evaluate its potential application in dermatology, images of living skin acquired with and without compounding were compared. The quality of the compounded images was found to be substantially better. A signal-to-noise gain close to a factor of two (the theoretical maximum attainable using four detectors) was achieved without a significant loss in resolution. The method can be applied to arrays with a larger number of elements, potentially enabling more advanced forms of spatial-diversity, and adaptive-optics methods.
引用
收藏
页码:1427 / 1439
页数:13
相关论文
共 18 条
  • [1] SPECKLE IN ULTRASOUND B-MODE SCANS
    BURCKHARDT, CB
    [J]. IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1978, 25 (01): : 1 - 6
  • [2] HIGH-RESOLUTION REFLECTOMETRY IN BIOLOGICAL TISSUES
    CLIVAZ, X
    MARQUISWEIBLE, F
    SALATHE, RP
    NOVAK, RP
    GILGEN, HH
    [J]. OPTICS LETTERS, 1992, 17 (01) : 4 - 6
  • [3] ASSESSMENT OF HYBRID SPECKLE REDUCTION ALGORITHMS
    FORSBERG, F
    HEALEY, AJ
    LEEMAN, S
    JENSEN, JA
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (11) : 1539 - 1549
  • [4] OPTICAL HETERODYNE DETECTION OF AN ATMOSPHERICALLY DISTORTED SIGNAL WAVE FRONT
    FRIED, DL
    [J]. PROCEEDINGS OF THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS, 1967, 55 (01): : 57 - &
  • [5] SOME FUNDAMENTAL PROPERTIES OF SPECKLE
    GOODMAN, JW
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1976, 66 (11) : 1145 - 1150
  • [6] OPTICAL COHERENCE TOMOGRAPHY
    HUANG, D
    SWANSON, EA
    LIN, CP
    SCHUMAN, JS
    STINSON, WG
    CHANG, W
    HEE, MR
    FLOTTE, T
    GREGORY, K
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. SCIENCE, 1991, 254 (5035) : 1178 - 1181
  • [7] OPTICAL COHERENCE MICROSCOPY IN SCATTERING MEDIA
    IZATT, JA
    HEE, MR
    OWEN, GM
    SWANSON, EA
    FUJIMOTO, JG
    [J]. OPTICS LETTERS, 1994, 19 (08) : 590 - 592
  • [8] Knuttel A, 1996, P SOC PHOTO-OPT INS, V2655, P258, DOI 10.1117/12.237484
  • [9] OPTICAL-COHERENCE TOMOGRAPHY OF A DENSE TISSUE - STATISTICS OF ATTENUATION AND BACKSCATTERING
    SCHMITT, JM
    KNUTTEL, A
    YADLOWSKY, M
    ECKHAUS, MA
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (10) : 1705 - 1720
  • [10] SCHMITT JM, 1993, P SOC PHOTO-OPT INS, V1889, P197, DOI 10.1117/12.155715