Complications of invasive video-EEG monitoring with subdural grid electrodes

被引:209
作者
Hamer, HM
Morris, HH
Mascha, EJ
Karafa, MT
Bingaman, WE
Bej, MD
Burgess, RC
Dinner, DS
Foldvary, NR
Hahn, JF
Kotagal, P
Najm, I
Wyllie, E
Lüders, HO
机构
[1] Univ Marburg, Dept Neurol, D-35033 Marburg, Germany
[2] Cleveland Clin Fdn, Dept Neurol, Cleveland, OH USA
[3] Cleveland Clin Fdn, Dept Neurol Surg, Cleveland, OH USA
[4] Cleveland Clin Fdn, Dept Biostat & Epidemiol, Cleveland, OH USA
关键词
D O I
10.1212/WNL.58.1.97
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To evaluate the risk factors, type, and frequency of complications during video-EEG monitoring with subdural grid electrodes. Methods: The authors retrospectively reviewed the records of all patients who underwent invasive monitoring with subdural grid electrodes (n = 198 monitoring sessions on 187 patients; median age: 24 years; range: 1 to 50 years) at the Cleveland Clinic Foundation from 1980 to 1997. Results: From 1980 to 1997, the complication rate decreased (p = 0.003). In the last 5 years, 19/99 patients (19%) had complications, including two patients (2%) with permanent sequelae. In the last 3 years, the complication rate was 13.5% (n = 5/37) without permanent deficits. Overall, complications occurred during 52 monitoring sessions (26.3%): infection (n = 24; 12.1%), transient neurologic deficit (n = 22; 11.1%,), epidural hematoma (n = 5; 2.5%), increased intracranial pressure (n = 5; 2.5%), and infarction (n = 3; 1.5%,). One patient (0.5%) died during grid insertion. Complication occurrence was associated with greater number of grids/electrodes (p = 0.021/p = 0.052; especially >60 electrodes), longer duration of monitoring (p = 0.004; especially >10 days), older age of the patient (p = 0.005), left-sided grid insertion (p = 0.01), and burr holes in addition to the craniotomy (p = 0.022). No association with complications was found for number of seizures, IQ, anticonvulsants, or grid localization. Conclusions: Invasive monitoring with grid electrodes was associated with significant complications, Most of them were transient. Increased complication rates were related to left-sided grid insertion and longer monitoring with a greater number of electrodes (especially more than 60 electrodes). Improvements in grid technology, surgical technique, and postoperative care resulted in significant reductions in the complication rate.
引用
收藏
页码:97 / 103
页数:7
相关论文
共 23 条
[11]  
ROSS DA, 1991, J NEUROSURG, V75, P832
[12]   Intracerebral depth electrode monitoring in partial epilepsy: The morbidity and efficacy of placement using magnetic resonance image-guided stereotactic surgery [J].
Ross, DA ;
Brunberg, JA ;
Drury, I ;
Henry, TR .
NEUROSURGERY, 1996, 39 (02) :327-333
[13]   A 13-year experience with epilepsy surgery [J].
Smith, JR ;
Lee, MR ;
Jenkins, PD ;
King, DW ;
Murro, AM ;
Park, YD ;
Lee, GP ;
Meador, KJ ;
Loring, DW .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1999, 73 (1-4) :98-103
[14]   AN 8-YEAR EXPERIENCE WITH DEPTH ELECTRODES IN THE EVALUATION OF ABLATIVE SEIZURE SURGERY CANDIDATES [J].
SMITH, JR ;
FLANIGIN, HF ;
KING, DW ;
GALLAGHER, BB ;
MURRO, AM ;
HOLMES, GL ;
CAMPBELL, LR ;
LEE, G ;
WHELESS, J .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1990, 54-5 :60-66
[15]   COMBINED DEPTH AND SUBDURAL ELECTRODE INVESTIGATION IN UNCONTROLLED EPILEPSY [J].
SPENCER, SS ;
SPENCER, DD ;
WILLIAMSON, PD ;
MATTSON, R .
NEUROLOGY, 1990, 40 (01) :74-79
[16]   DEPTH VERSUS SUBDURAL ELECTRODE STUDIES FOR UNLOCALIZED EPILEPSY [J].
SPENCER, SS .
JOURNAL OF EPILEPSY, 1989, 2 (03) :123-127
[17]   COMPARISON OF DEPTH AND SUBDURAL ELECTRODES IN RECORDING TEMPORAL-LOBE SEIZURES [J].
SPERLING, MR ;
OCONNOR, MJ .
NEUROLOGY, 1989, 39 (11) :1497-1504
[18]   The safety and efficacy of chronically implanted subdural electrodes: A prospective study [J].
Swartz, BE ;
Rich, JR ;
Dwan, PS ;
DeSalles, A ;
Kaufman, MH ;
Walsh, GO ;
DelgadoEscueta, AV .
SURGICAL NEUROLOGY, 1996, 46 (01) :87-93
[19]   FUNCTIONAL NEUROSURGERY IN THE TREATMENT OF EPILEPSY IN THE NETHERLANDS - ASPECTS OF PRESURGICAL EVALUATION AND THE CONTRIBUTION OF SUBDURAL AND STEREOTAXICALLY IMPLANTED DEPTH ELECTRODES IN THE DUTCH WORKGROUP FOR FUNCTIONAL SURGERY [J].
VANVEELEN, CWM ;
DEBETS, RMC .
ACTA NEUROCHIRURGICA, 1993, 124 (01) :7-10
[20]   Morbidity and infection in combined subdural grid and strip electrode investigation for intractable epilepsy [J].
Wiggins, GC ;
Elisevich, K ;
Smith, BJ .
EPILEPSY RESEARCH, 1999, 37 (01) :73-80