Thermoplastic microchannel fabrication using carbon dioxide laser ablation

被引:28
作者
Wang, SC [1 ]
Lee, CY [1 ]
Chen, HP [1 ]
机构
[1] Natl Chung Cheng Univ, Dept Chem & Biochem, Chiayi 62107, Taiwan
关键词
microfabrication; microfluidics; electrophoretic mobility; plastics;
D O I
10.1016/j.chroma.2005.10.039
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report the procedures of machining microchannels on Vivak co-polyester thermoplastic substrates using a simple industrial CO2 laser marker. To avoid overheating the substrates, we develop low-power marking techniques in nearly anaerobic environment. These procedures are able to machine microchannels at various aspect ratios. Either straight or serpent channel can be easily marked. Like the wire-embossed channel walls, the ablated channel surfaces become charged after alkaline hydrolysis treatment. Stable electroosmotic flow in the charged conduit is observed to be of the same order of magnitude as that in fused silica capillary. Typical dynamic coating protocols to alter the conduit surface properties are transferable to the ablated channels. The effects of buffer acidity on electroosmotic mobility in both bare and coated channels are similar to those in fused silica capillaries. Using video microscopy we also demonstrate that this device is useful in distinguishing the electrophoretic mobility of bare and latex particles from that of functionalized ones. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:252 / 257
页数:6
相关论文
共 19 条
[1]   Plastic advances microfluidic devices. [J].
Boone, T ;
Fan, ZH ;
Hooper, H ;
Ricco, A ;
Tan, HD ;
Williams, S .
ANALYTICAL CHEMISTRY, 2002, 74 (03) :78A-86A
[2]   Direct-write laser micromachining and universal surface modification of PMMA for device development [J].
Cheng, JY ;
Wei, CW ;
Hsu, KH ;
Young, TH .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 99 (01) :186-196
[3]   A microfabricated fluorescence-activated cell sorter [J].
Fu, AY ;
Spence, C ;
Scherer, A ;
Arnold, FH ;
Quake, SR .
NATURE BIOTECHNOLOGY, 1999, 17 (11) :1109-1111
[4]   CURRENT-MONITORING METHOD FOR MEASURING THE ELECTROOSMOTIC FLOW-RATE IN CAPILLARY ZONE ELECTROPHORESIS [J].
HUANG, XH ;
GORDON, MJ ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1988, 60 (17) :1837-1838
[5]   Laser modification of preformed polymer microchannels: Application to reduce band broadening around turns subject to electrokinetic flow [J].
Johnson, TJ ;
Ross, D ;
Gaitan, M ;
Locascio, LE .
ANALYTICAL CHEMISTRY, 2001, 73 (15) :3656-3661
[6]   CO2-laser micromachining and back-end processing for rapid production of PMMA-based microfluidic systems [J].
Klank, H ;
Kutter, JP ;
Geschke, O .
LAB ON A CHIP, 2002, 2 (04) :242-246
[7]   Measurement of electroosmotic flow in plastic imprinted microfluid devices and the effect of protein adsorption on flow rate [J].
Locascio, LE ;
Perso, CE ;
Lee, CS .
JOURNAL OF CHROMATOGRAPHY A, 1999, 857 (1-2) :275-284
[8]  
Madou M., 1997, Fundamentals of Microfabrication
[9]  
Minerick AR, 2002, ELECTROPHORESIS, V23, P2165, DOI 10.1002/1522-2683(200207)23:14<2165::AID-ELPS2165>3.0.CO
[10]  
2-#