Stent design related neointimal tissue proliferation in human coronary arteries -: An intravascular ultrasound study

被引:36
作者
Hoffmann, R
Jansen, C
König, A
Haager, PK
Kerckhoff, G
Vom Dahl, J
Klauss, V
Hanrath, P
Mudra, H
机构
[1] Univ Aachen, Clin RWTH Aachen, Med Clin 1, Aachen, Germany
[2] Univ Munich, Dept Cardiol, Div Cardiol, Dept Internal Med, Munich, Germany
[3] Krankenhaus Neuperlach, Dept Cardiol, Munich, Germany
关键词
intimal hyperplasia; intravascular ultrasound; restenosis; stent;
D O I
10.1053/euhj.2001.2606
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Histological restenosis models in animals have indicated that stent design has a significant impact on vessel trauma during stent implantation and on the amount of subsequent neointimal tissue proliferation. The impact of different stent designs on intimal hyperplasia in human atherosclerotic coronary arteries has not been determined. Methods and Results Angiographic and intravascular ultrasound studies were performed at the 6 month follow-up in 131 consecutive native coronary lesions of 131 patients treated with 50 Multi-Link (TM) stents, 40 InFlow (TM) stents and 41 Palmaz-Schatz (TM) stents. Lumen and stent cross-sectional areas (CSA) were measured at I mm axial increments. Mean intimal hyperplasia cross-sectional area (stent CSA - lumen CSA) and mean intimal hyperplasia thickness were calculated. Intravascular ultrasound demonstrated different levels of intimal. hyperplasia proliferation for the three stents. Mean intimal hyperplasia thickness was 0.16 +/- 0.08 mm for Multi-Link stents, 0.26 +/- 0.19 mm for Palmaz-Schatz stents and 0.39 +/- 0.14 mm for Inflow stents (P <0.001). Multivariate analysis proved that stent type was the only independent predictor of intimal hyperplasia thickness at follow-Lip (P <0.001). Conclusion Coronary stent design has a significant impact on subsequent intimal hyperplasia after implantation into atherosclerotic human coronary arteries. The corrugated ring design of the Multi-Link stent proved to result in less tissue proliferation at 6-month follow-up than the tubular slotted design of Palmaz-Schatz and InFlow stents. (C) 2001 The European Society of Cardiology.
引用
收藏
页码:2007 / 2014
页数:8
相关论文
共 26 条
[1]  
Baim DS, 1998, CIRCULATION, V98, P661
[2]   Paired comparison of vascular wall reactions to Palmaz stents, Strecker tantalum stents, and Wallstents in canine iliac and femoral arteries [J].
Barth, KH ;
Virmani, R ;
Froelich, J ;
Takeda, T ;
Lossef, SV ;
Newsome, J ;
Jones, R ;
Lindisch, D .
CIRCULATION, 1996, 93 (12) :2161-2169
[3]   Intravascular ultrasound-guided optimized stent deployment - Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study) [J].
de Jaegere, P ;
Mudra, H ;
Figulla, H ;
Almagor, Y ;
Doucet, S ;
Penn, I ;
Colombo, A ;
Hamm, C ;
Bartorelli, A ;
Rothman, M ;
Nobuyoshi, M ;
Yamaguchi, T ;
Voudris, V ;
DiMario, C ;
Makovski, S ;
Hausmann, D ;
Rowe, S ;
Rabinovich, S ;
Sunamura, M ;
van Es, GA .
EUROPEAN HEART JOURNAL, 1998, 19 (08) :1214-1223
[4]  
DIRSCHINGER J, 1999, EUR HEART J, V30, pA3262
[5]  
Emanuelsson H, 1997, J INVASIVE CARDIOL, V9, P561
[6]   MEASUREMENT AND CONTROL IN THE PROCESS INDUSTRIES - EDITORIAL VIEWPOINT [J].
FISHER, TG .
ISA TRANSACTIONS, 1994, 33 (01) :1-2
[7]   Stent and artery geometry determine intimal thickening independent of arterial injury [J].
Garasic, JM ;
Edelman, ER ;
Squire, JC ;
Seifert, P ;
Williams, MS ;
Rogers, C .
CIRCULATION, 2000, 101 (07) :812-818
[8]   Intimal hyperplasia thickness at follow-up is independent of stent size: A serial intravascular ultrasound study [J].
Hoffmann, R ;
Mintz, GS ;
Pichard, AD ;
Kent, KM ;
Satler, LF ;
Leon, MB .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (10) :1168-1172
[9]   Overestimation of acute lumen gain and late lumen loss by quantitative coronary angiography (compared with intravascular ultrasound) in stented lesions [J].
Hoffmann, R ;
Mintz, GS ;
Popma, JJ ;
Satler, LF ;
Kent, KM ;
Pichard, AD ;
Leon, MB .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (10) :1277-1281
[10]   Patterns and mechanisms of in-stent restenosis - A serial intravascular ultrasound study [J].
Hoffmann, R ;
Mintz, GS ;
Dussaillant, GR ;
Popma, JJ ;
Pichard, AD ;
Satler, LF ;
Kent, KM ;
Griffin, J ;
Leon, MB .
CIRCULATION, 1996, 94 (06) :1247-1254