Monitoring cocaine use in substance-abuse-treatment patients by sweat and urine testing

被引:46
作者
Preston, KL [1 ]
Huestis, MA
Wong, CJ
Umbricht, A
Goldberger, BA
Cone, EJ
机构
[1] Natl Inst Drug Abuse, Intramural Res Program, Baltimore, MD 21224 USA
[2] Univ Vermont, Dept Psychol, Burlington, VT 05405 USA
[3] Univ Florida, Coll Med, Dept Pathol Immunol & Lab Med, Gainesville, FL USA
关键词
D O I
10.1093/jat/23.5.313
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sweat and urine specimens were collected from 44 methadone-maintenance patients to evaluate the use of sweat testing to monitor cocaine use. Paired sweat patches that were applied and removed weekly (on Tuesdays) were compared with 3-5 consecutive urine specimens collected Mondays, Wednesdays, and Fridays. All patches (N = 930) were extracted in 2.5 mL of solvent and analyzed by ELISA immunoassay (cutoff concentration 10 ng/mL); a subset of patches (N = 591) was also analyzed by gas chromatography-mass spectrometry (GC-MS) for cocaine, benzoylecgonine (BZE), and ecgonine methyl ester (EME) (cutoff concentration 5 ng/mL). Urine specimens were subjected to qualitative analysis by EMIT (cutoff 300 ng/mL) and subsets were analyzed by TDx (semiquantitative, LOD 30 ng/mL) and by GC-MS for cocaine (LOD 5 ng/mL). Results were evaluated to (1) determine the relative amounts of cocaine and its metabolites in sweat; (2) assess replicability in duplicate patches; (3) compare ELISA and GC-MS results for cocaine in sweat; and (4) compare the detection of cocaine use by sweat and urine testing. Cocaine was detected by GC-MS in 99% of ELISA-positive sweat patches; median concentrations of cocaine, BZE, and EME were 378, 78.7, and 74 ng/mL, respectively. Agreement in duplicate patches was approximately 90% by ELISA analysis. The sensitivity, specificity, and efficiency of sweat ELISA cocaine results as compared with sweat GC-MS results were 93.6%, 91.3%, and 93.2%, respectively. The sensitivity, specificity, and efficiency between ELISA sweat patch and EMIT urine results were 97.6%, 60.5%, and 77.7%, respectively. These results support the use of sweat patches for monitoring cocaine use, though further evaluation is needed.
引用
收藏
页码:313 / 322
页数:10
相关论文
共 27 条
[1]  
Balabanova S, 1992, Beitr Gerichtl Med, V50, P111
[2]  
BALABANOVA S, 1989, BEITRAGE GERICHTLICH, V48, P45
[3]  
Balabanova S., 1989, LABORATORIUMSMEDIZIN, V13, P479
[4]   MONITORING DRUG-USE WITH A SWEAT PATCH - AN EXPERIMENT WITH COCAINE [J].
BURNS, M ;
BASELT, RC .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1995, 19 (01) :41-48
[5]   SWEAT TESTING FOR HEROIN, COCAINE, AND METABOLITES [J].
CONE, EJ ;
HILLSGROVE, MJ ;
JENKINS, AJ ;
KEENAN, RM ;
DARWIN, WD .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1994, 18 (06) :298-305
[6]   VALIDITY TESTING OF THE TDX COCAINE METABOLITE ASSAY WITH HUMAN SPECIMENS OBTAINED AFTER INTRAVENOUS COCAINE ADMINISTRATION [J].
CONE, EJ ;
MENCHEN, SL ;
MITCHELL, J .
FORENSIC SCIENCE INTERNATIONAL, 1988, 37 (04) :265-275
[7]  
Eskridge KD, 1997, PHARMACOTHERAPY, V17, P497
[8]   Detection of methamphetamine in sweat by EIA and GC-MS [J].
Fay, J ;
Fogerson, R ;
Schoendorfer, D ;
Niedbala, RS ;
Spiehler, V .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1996, 20 (06) :398-403
[9]  
FORTNER N, 1999, COMMUNICATION
[10]   Rapid liquid-liquid extraction of cocaine from urine for gas chromatographic mass spectrometric analysis [J].
Garside, D ;
Goldberger, BA ;
Preston, KL ;
Cone, EJ .
JOURNAL OF CHROMATOGRAPHY B, 1997, 692 (01) :61-65