A disposable paper-based electrochemical sensor with an addressable electrode array for cancer screening

被引:92
作者
Ge, Shenguang [1 ]
Ge, Lei [2 ]
Yan, Mei [1 ]
Song, Xianrang [3 ]
Yu, Jinghua [1 ]
Huang, Jiadong [1 ]
机构
[1] Univ Jinan, Sch Chem & Chem Engn, Shandong Univ, Key Lab Chem Sensing & Anal, Jinan 250022, Peoples R China
[2] Univ Jinan, Shandong Prov Key Lab Preparat & Measurement Bldg, Jinan 250022, Peoples R China
[3] Shandong Tumor Hosp, Canc Res Ctr, Jinan 250117, Peoples R China
关键词
LAB-ON-PAPER; MICROELECTRODE ARRAYS; CARE DIAGNOSTICS; POINT; IMMUNODEVICE; DEVICE; IMMUNOASSAY;
D O I
10.1039/c2cc34887j
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel addressable electrode array based on paper was assembled on the crossing points of the row/column electrodes to form a 4 x 6 sensor array by a facile home-made device-holder, one paper layer contained the sensing sites, the other paper layer the printed counter electrode and reference electrode.
引用
收藏
页码:9397 / 9399
页数:3
相关论文
共 17 条
[1]   In-Plane Parallel Scanning: A Microarray Technology for Point-of-Care Testing [J].
Duer, Reuven ;
Lund, Russell ;
Tanaka, Richard ;
Christensen, Douglas A. ;
Herron, James N. .
ANALYTICAL CHEMISTRY, 2010, 82 (21) :8856-8865
[2]   Genetic Analysis of H1N1 Influenza Virus from Throat Swab Samples in a Microfluidic System for Point-of-Care Diagnostics [J].
Ferguson, B. Scott ;
Buchsbaum, Steven F. ;
Wu, Ting-Ting ;
Hsieh, Kuangwen ;
Xiao, Yi ;
Sun, Ren ;
Soh, H. Tom .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2011, 133 (23) :9129-9135
[3]   Three-dimensional paper-based electrochemiluminescence immunodevice for multiplexed measurement of biomarkers and point-of-care testing [J].
Ge, Lei ;
Yan, Jixian ;
Song, Xianrang ;
Yan, Mei ;
Ge, Shenguang ;
Yu, Jinghua .
BIOMATERIALS, 2012, 33 (04) :1024-1031
[4]   Point of Care Diagnostics: Status and Future [J].
Gubala, Vladimir ;
Harris, Leanne F. ;
Ricco, Antonio J. ;
Tan, Ming X. ;
Williams, David E. .
ANALYTICAL CHEMISTRY, 2012, 84 (02) :487-515
[5]   Microelectrode arrays and ceric ammonium nitrate: A simple strategy for developing new site-selective synthetic methods [J].
Kesselring, David ;
Maurer, Karl ;
Moeller, Kevin D. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (34) :11290-+
[6]   Fabrication of TiO2 and Metal Nanoparticle-Microelectrode Arrays by Photolithography and Site-Selective Photocatalytic Deposition [J].
Li, Xiaoguang ;
Tian, Yang ;
Xia, Peipei ;
Luo, Yongping ;
Rui, Qi .
ANALYTICAL CHEMISTRY, 2009, 81 (19) :8249-8255
[7]   Carbon-Ring Microelectrode Arrays for Electrochemical Imaging of Single Cell Exocytosis: Fabrication and Characterization [J].
Lin, Yuqing ;
Trouillon, Raphael ;
Svensson, Maria I. ;
Keighron, Jacqueline D. ;
Cans, Ann-Sofie ;
Ewing, Andrew G. .
ANALYTICAL CHEMISTRY, 2012, 84 (06) :2949-2954
[8]   An addressable microelectrode array for electrochemical detection [J].
Lin, Zhenyu ;
Takahashi, Yasufumi ;
Kitagawa, Yuusuke ;
Umemura, Taizo ;
Shiku, Hitoshi ;
Matsue, Tomokazu .
ANALYTICAL CHEMISTRY, 2008, 80 (17) :6830-6833
[9]   Electrochemical Gene-Function Analysis for Single Cells with Addressable Microelectrode/Microwell Arrays [J].
Lin, Zhenyu ;
Takahashi, Yasufumi ;
Murata, Tatsttya ;
Takeda, Michiaki ;
Ino, Kosuke ;
Shiku, Hitoshi ;
Matsue, Tomokazu .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2009, 48 (11) :2044-2046
[10]   Development of a digital microfluidic platform for point of care testing [J].
Sista, Ramakrishna ;
Hua, Zhishan ;
Thwar, Prasanna ;
Sudarsan, Arjun ;
Srinivasan, Vijay ;
Eckhardt, Allen ;
Pollack, Michael ;
Pamula, Vamsee .
LAB ON A CHIP, 2008, 8 (12) :2091-2104