Ultrasound imaging of liver metastases in the delayed parenchymal phase following administration of Sonazoid™ using a destructive mode technique (Agent Detection lmaging™)

被引:22
作者
Edey, A. J. [1 ]
Ryan, S. M. [1 ]
Beese, R. C. [1 ]
Gordon, P. [2 ]
Sidhu, P. S. [1 ]
机构
[1] Kings Coll Hosp London, Dept Radiol, London SE5 9RS, England
[2] GE Healthcare, Oslo, Norway
关键词
D O I
10.1016/j.crad.2008.03.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
AIM: To determine whether delayed-phase liver imaging using a destructive imaging mode is able to provide similar information to phase-inversion imaging regarding detection and conspicuity of liver metastases. MATERIAL AND METHODS: Patients with a known primary malignancy with suspected liver metastases were recruited. Ultrasound was performed at baseline, and up to 5 min after the administration of Sonazoid (TM), using phase-inversion imaging at both tow and high mechanical indices (MI) and at 10-15 min using destructive imaging. One of four doses of Sonazoid (TM) was used: 0.008, 0.08, 0.12, and 0.36 mu l/kg of body weight. Two observers documented lesion number and conspicuity subjectively, and divided the patients into group A (no lesions), group B (one to seven lesions), and group C-I (III) (more than eight lesions, subdivided with increasing lesion number) depending on the number of lesions and categories I-IV based on lesion conspicuity. These parameters were compared with contrast-enhanced computed tomography (CECT) as the reference standard. RESULTS: Sixteen patients were examined (six women, 10 men), mean age 67.3 years (range 48-83 years). Based on CECT imaging, the division was as follows: group A n 1, group B n = 8, group C-I n 1, group C-II n - 4, group C-III n - 2. The accuracy of baseline ultrasound versus CECT was 75% (in 12 of the 16 patients the group concurred) and the accuracy for contrast-enhanced ultrasound (CEUS) versus CECT was 93.8% (15/16). There was a significant improvement in lesion conspicuity for both low (p - 0.0029) and high MI phase-inversion (p = 0.0004) and destructive (p - 0.0015) CEUS imaging in comparison with baseline ultrasound. Artefact was noted at higher doses of Sonazoid (TM); and no side effects were recorded. CONCLUSION: Following a single, intravenous injection of Sonazoid (TM), the properties of this microbubble allow for a and robust examination of the liver using two different techniques with comparable results. (C) 2008 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1112 / 1120
页数:9
相关论文
共 29 条
[1]
Detection and characterisation of liver metastases [J].
Albrecht, T ;
Hohmann, J ;
Oldenburg, A ;
Skrok, J ;
Wolf, KJ .
EUROPEAN RADIOLOGY, 2004, 14 :P25-P33
[2]
Guidelines for the use of contrast agents in ultrasound [J].
Albrecht, T ;
Blomley, M ;
Bolondi, L ;
Claudon, M ;
Correas, JM ;
Cosgrove, D ;
Greiner, L ;
Jäger, K ;
de Jong, N ;
Leen, E ;
Lencioni, R ;
Lindsell, D ;
Martegani, A ;
Solbiati, L ;
Thorelius, L ;
Tranquart, F ;
Weskott, HP ;
Whittingham, T .
ULTRASCHALL IN DER MEDIZIN, 2004, 25 (04) :249-256
[3]
Imaging of liver metastases with contrast-specific low-MI real-time ultrasound and SonoVue [J].
Albrecht, T ;
Oldenburg, A ;
Hohmann, J ;
Skrok, J ;
Hoffmann, CW ;
Schettler, S ;
Wolf, KJ .
EUROPEAN RADIOLOGY, 2003, 13 (Suppl 3) :N79-N86
[4]
*AM COLL RAD, ACR APPR CRIT GASTR
[5]
Microbubble Contrast-enhanced Ultrasound Features of Common Focal Liver Lesions: A Guide for the Novice [J].
Berry, Jonathan D. ;
Sidhu, Paul S. .
ULTRASOUND, 2006, 14 (04) :190-201
[6]
Blomley MJ, 1999, RADIOLOGY, V213P, P491
[7]
Improved imaging of liver metastases with stimulated acoustic emission in the late phase of enhancement with the US contrast agent SH U 508A: Early experience [J].
Blomley, MJK ;
Albrecht, T ;
Cosgrove, DO ;
Patel, N ;
Jayaram, V ;
Butler-Barnes, J ;
Eckersley, RJ ;
Bauer, A ;
Schlief, R .
RADIOLOGY, 1999, 210 (02) :409-416
[8]
Do different types of liver lesions differ in their uptake of the microbubble contrast agent SHU 508A in the late liver phase? Early experience [J].
Blomley, MJK ;
Sidhu, PS ;
Cosgrove, DO ;
Albrecht, T ;
Harvey, CJ ;
Heckemann, RA ;
Butler-Barnes, J ;
Eckersley, RJ ;
Basilico, R .
RADIOLOGY, 2001, 220 (03) :661-667
[9]
Blood flow patterns in focal liver lesions at microbubble-enhanced US [J].
Brannigan, M ;
Burns, PN ;
Wilson, SR .
RADIOGRAPHICS, 2004, 24 (04) :921-935
[10]
Improved characterization of liver lesions with liver-phase uptake of liver-specific microbubbles: Prospective multicenter study [J].
Bryant, TH ;
Blomley, MJ ;
Albrecht, T ;
Sidhu, PS ;
Leen, ELS ;
Basilico, R ;
Pilcher, JM ;
Bushby, LH ;
Hoffmann, CW ;
Harvey, CJ ;
Lynch, M ;
MacQuarrie, J ;
Paul, D ;
Cosgrove, DO .
RADIOLOGY, 2004, 232 (03) :799-809