Estimation of the ventricular fibrillation duration by autoregressive modeling

被引:9
作者
Baykal, A
Ranjan, R
Thakor, NV
机构
[1] JOHNS HOPKINS UNIV,SCH MED,DEPT BIOMED ENGN,BALTIMORE,MD 21205
[2] JOHNS HOPKINS UNIV,DEPT BIOMED ENGN,BALTIMORE,MD 21205
关键词
autoregressive processes; biomedical signal processing; electrocardiography; signal detection; ventricular fibrillation;
D O I
10.1109/10.568910
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An accurate estimation of ventricular fibrillation (VF) duration could be critical in selecting the most effective therapeutic intervention. We test the hypothesis that changes in frequency content of VF signals can be quantified by using autoregressive (AR) modeling, and the duration since the onset of VF can be estimated by using this method. VF signals were recorded for up to 300 s in five isolated rabbit hearts. Fourth-order AR parameters of successive segments were estimated, and frequencies of the first poles (the pole with lower frequency) were pooled together and a curve was fitted: F(t) = A exp (-alpha(t)) + B, where F(t) is the estimated frequency of the first pole at t(')th time instant, alpha is the decay constant, B is the offset frequency, and A is the frequency at time zero minus the offset frequency. The utility of this curve in estimating the VF duration was tested in four new experiments, and the difference between the actual and the estimated VF duration (estimation error) was calculated. F(t), the frequency of the first pole, decreased from 12 to 6 Hz with duration of VF, while the frequency of the other pole decreased from 25 to 20 Hz. Parameters of the fitted curve were calculated as A = 7.8. alpha = 0.0041 and B was selected as four. Testing on a new set of VF signals produced very little estimation error for the first 100 s of VF, although this error increased with VF duration. For these new signals, the mean value of the absolute estimation error was 26 s. Results of this study show that changes in the frequency content of electrocardiogram (EGG) during VF can be quantified by AR modeling and that the frequency changes associated with a pole of this model can be used to estimate the VF duration.
引用
收藏
页码:349 / 356
页数:8
相关论文
共 28 条
[1]   APPLICATION OF ADAPTIVE FILTERS TO NONINVASIVE ACOUSTICAL DETECTION OF CORONARY OCCLUSIONS BEFORE AND AFTER ANGIOPLASTY [J].
AKAY, M ;
AKAY, YM ;
WELKOWITZ, W ;
SEMMLOW, JL ;
KOSTIS, JB .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (02) :176-184
[2]   UNIFIED APPROACH TO SHORT-TIME FOURIER-ANALYSIS AND SYNTHESIS [J].
ALLEN, JB ;
RABINER, LR .
PROCEEDINGS OF THE IEEE, 1977, 65 (11) :1558-1564
[3]   DISTRIBUTION OF AORTIC MECHANICAL PROSTHETIC VALVE CLOSURE SOUND MODEL PARAMETERS ON THE SURFACE OF THE CHEST [J].
BAYKAL, A ;
IDER, YZ ;
KOYMEN, H .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (04) :358-370
[4]   TIME-VARIANT POWER SPECTRUM ANALYSIS FOR THE DETECTION OF TRANSIENT EPISODES IN HRV SIGNAL [J].
BIANCHI, AM ;
MAINARDI, L ;
PETRUCCI, E ;
SIGNORINI, MG ;
MAINARDI, M ;
CERUTTI, S .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (02) :136-144
[5]  
BOASHASH B, 1992, TIME FREQUENCY SIGNA, P547
[6]   FOURIER-ANALYSIS OF VENTRICULAR-FIBRILLATION OF VARIED ETIOLOGY [J].
CARLISLE, EJF ;
ALLEN, JD ;
KERNOHAN, WG ;
ANDERSON, J ;
ADGEY, AAJ .
EUROPEAN HEART JOURNAL, 1990, 11 (02) :173-181
[7]   FOURIER-ANALYSIS OF VENTRICULAR-FIBRILLATION AND SYNCHRONIZATION OF DC COUNTERSHOCKS IN DEFIBRILLATION [J].
CARLISLE, EJF ;
ALLEN, JD ;
BAILEY, A ;
KERNOHAN, WG ;
ANDERSON, J ;
ADGEY, AAJ .
JOURNAL OF ELECTROCARDIOLOGY, 1988, 21 (04) :337-343
[8]   TIME FREQUENCY-DISTRIBUTIONS - A REVIEW [J].
COHEN, L .
PROCEEDINGS OF THE IEEE, 1989, 77 (07) :941-981
[9]   MODERN SPECTRAL-ANALYSIS TECHNIQUES FOR BLOOD-FLOW VELOCITY AND SPECTRAL MEASUREMENTS WITH PULSED DOPPLER ULTRASOUND [J].
DAVID, JY ;
JONES, SA ;
GIDDENS, DP .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (06) :589-596
[10]   THE MEDIAN FREQUENCY OF THE ECG DURING VENTRICULAR-FIBRILLATION - ITS USE IN AN ALGORITHM FOR ESTIMATING THE DURATION OF CARDIAC-ARREST [J].
DZWONCZYK, R ;
BROWN, CG ;
WERMAN, HA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (06) :640-646