Differentiation of neoplastic from bland macroscopic portal vein thrombi using dual-energy spectral CT imaging: a pilot study

被引:85
作者
Qian, Li Jun [1 ]
Zhu, Jiong [1 ]
Zhuang, Zhi Guo [1 ]
Xia, Qiang [2 ]
Cheng, Yu Fan [3 ]
Li, Jian Ying [4 ]
Xu, Jian Rong [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Med, Renji Hosp, Dept Radiol, Shanghai 200127, Peoples R China
[2] Shanghai Jiao Tong Univ, Dept Hepat Surg, Renji Hosp, Sch Med, Shanghai 200127, Peoples R China
[3] Chang Gung Univ, Coll Med, Liver Transplantat Program, Chang Gung Mem Hosp,Kaohsiung Med Ctr, Kaohsiung 83305, Taiwan
[4] GE Healthcare China, CT Imaging Res Ctr, Beijing 100176, Peoples R China
关键词
X-ray computed tomography; Dual-energy CT; Thrombosis; Portal vein; Hepatocellular carcinoma; HEPATOCELLULAR-CARCINOMA; BENIGN; DIAGNOSIS; LIVER; VARIABILITY; ANGIOGRAPHY; CIRRHOSIS; US;
D O I
10.1007/s00330-012-2477-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
To assess the feasibility and value of dual-energy spectral computed tomography (DESCT) imaging for differentiating neoplastic from bland macroscopic portal vein (PV) thrombi. Computed tomography (CT) images of 44 patients with macroscopic PV thrombus (bland group, n = 16; neoplastic group, n = 28) were reviewed. Iodine-based material decomposition images in the portal venous phase were reconstructed to compare the iodine indices between groups, including thrombus iodine density (I (T)), thrombus-aorta iodine density ratio (I (T)/I (A)), and thrombus-PV iodine density ratio (I (T)/I (P)). Differential diagnostic performances of DESCT were calculated in the subgroup of 21 patients with histopathological evidence (bland group, n = 12; neoplastic group, n = 9). The iodine indices of the neoplastic group were significantly higher than those in the bland group (P < 0.001). A threshold I (T) of 1.14 mg/mL, I (T)/I (A) of 0.17, and I (T)/I (P) of 0.17 in the portal venous phase yielded 100 %, 88.9 %, and 100 % sensitivity, and 91.7 %, 91.7 %, and 83.3 % specificity, respectively, in differentiating neoplastic from bland PV thrombi. DESCT imaging with quantification of thrombus iodine density in the portal venous phase appears to be a promising new method for distinguishing neoplastic from bland macroscopic PV thrombi. aEuro cent Differentiating the nature of portal vein thrombus is of great clinical significance. aEuro cent Iodine-based material decomposition imaging reflects iodine distribution after contrast media administration. aEuro cent Dual-energy CT with iodine quantification can distinguish bland from neoplastic PV thrombi.
引用
收藏
页码:2178 / 2185
页数:8
相关论文
共 31 条
[1]
Dual-energy-CT of hypervascular liver lesions in patients with HCC: investigation of image quality and sensitivity [J].
Altenbernd, Jens ;
Heusner, Till A. ;
Ringelstein, Adrian ;
Ladd, Susanne C. ;
Forsting, Michael ;
Antoch, Gerald .
EUROPEAN RADIOLOGY, 2011, 21 (04) :738-743
[2]
Stone-Targeted Dual-Energy CT: A New Diagnostic Approach to Urinary Calculosis [J].
Ascenti, Giorgio ;
Siragusa, Carmelo ;
Racchiusa, Sergio ;
Ielo, Isidora ;
Privitera, Giambattista ;
Midili, Federica ;
Mazziotti, Silvio .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (04) :953-958
[3]
Blake MA, 2011, RADIOGRAPHICS, V31, P1047, DOI 10.1148/rg.314105159
[4]
Mesenteric venous thrombosis: Diagnosis and noninvasive imaging [J].
Bradbury, MS ;
Kavanagh, PV ;
Bechtold, RE ;
Chen, MY ;
Ott, DJ ;
Regan, JD ;
Weber, TM .
RADIOGRAPHICS, 2002, 22 (03) :527-541
[5]
Differentiation of Malignant Thrombus from Bland Thrombus of the Portal Vein in Patients with Hepatocellular Carcinoma: Application of Diffusion-weighted MR Imaging [J].
Catalano, Onofrio A. ;
Choy, Garry ;
Zhu, Andrew ;
Hahn, Peter F. ;
Sahani, Dushyant V. .
RADIOLOGY, 2010, 254 (01) :154-162
[6]
Dual-Energy Multidetector CT: How Does It Work, What Can It Tell Us, and When Can We Use It in Abdominopelvic Imaging? [J].
Coursey, Courtney A. ;
Nelson, Rendon C. ;
Boll, Daniel T. ;
Paulson, Erik K. ;
Ho, Lisa M. ;
Neville, Amy M. ;
Marin, Daniele ;
Gupta, Rajan T. ;
Schindera, Sebastian T. .
RADIOGRAPHICS, 2010, 30 (04) :1037-1055
[7]
COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[8]
PORTAL-VEIN THROMBOSIS IN PATIENTS WITH CIRRHOSIS - DOES SONOGRAPHIC DETECTION OF INTRATHROMBUS FLOW ALLOW DIFFERENTIATION OF BENIGN AND MALIGNANT THROMBUS [J].
DODD, GD ;
MEMEL, DS ;
BARON, RL ;
EICHNER, L ;
SANTIGUIDA, LA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (03) :573-577
[9]
Bland and tumor thrombi in abdominal malignancies: magnetic resonance imaging assessment in a large oncologic patient population [J].
Engelbrecht, Marc ;
Akin, Oguz ;
Dixit, Devesh ;
Schwartz, Lawrence .
ABDOMINAL IMAGING, 2011, 36 (01) :62-68
[10]
Dual-Energy and Dual-Source CT: Is There a Role in the Abdomen and Pelvis? [J].
Fletcher, Joel G. ;
Takahashi, Naoki ;
Hartman, Robert ;
Guimaraes, Luis ;
Huprich, James E. ;
Hough, David M. ;
Yu, Lifeng ;
McCollough, Cynthia H. .