Dual-energy-CT of hypervascular liver lesions in patients with HCC: investigation of image quality and sensitivity

被引:90
作者
Altenbernd, Jens [1 ,2 ]
Heusner, Till A. [2 ]
Ringelstein, Adrian [2 ]
Ladd, Susanne C. [2 ]
Forsting, Michael [2 ]
Antoch, Gerald [2 ]
机构
[1] Univ Hosp Essen, Dept Diagnost & Intervent Radiol & Neuroradiol, D-45122 Essen, Germany
[2] Univ Duisburg Essen, Univ Hosp Essen, Dept Diagnost & Intervent Radiol & Neuroradiol, Essen, Germany
关键词
Liver; Dual-energy-CT; HCC; Staging; Hypervascular liver lesion; NOISE-REDUCTION FILTERS; CONTRAST-ENHANCED CT; PHASE HELICAL CT; HEPATOCELLULAR-CARCINOMA; COMPUTED-TOMOGRAPHY; INITIAL-EXPERIENCE; DOSE REDUCTION; ABDOMINAL CT; TUBE VOLTAGE; CHEST CT;
D O I
10.1007/s00330-010-1964-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
To investigate dual-energy CT of hypervascular liver lesions in patients with HCC. Forty patients with hepatocellular carcinomas were investigated with abdominal dual-energy CT. In each patient unenhanced and contrast-enhanced imaging with arterial und portovenous delay were performed. Hypervascular lesions were documented on arterial phase 80-kVp images, 140-kVp images, and the averaged arterial images by two radiologists. Subjective image quality (5-point scale, from 5 [excellent] to 1 [not interpretable]) was rated on all images. The mean number of hypervascular HCC lesions detected was 3.37 +/- 1.28 on 80-kVp images (p < 0.05), 1.43 +/- 1.13 on 140-kVp images (p < 0.05), and 2.57 +/- 1.2 on averaged images. The image quality was 0.3 +/- 0.5 for 80-kVp (p < 0.05), 1.6 +/- 0.5 for 140-kVp (p < 0.05) and 3.2 +/- 0.4 for the averaged images. Low-kVp images of dual-energy datasets are more sensitive in detecting hypervascular liver lesions. However, this increase in sensitivity goes along with a decrease in the subjective image quality of low-kVp images.
引用
收藏
页码:738 / 743
页数:6
相关论文
共 30 条
[1]
[Anonymous], 2004, EUROPEAN GUIDELINES
[2]
CLINICAL APPLICATION OF COMPTON AND PHOTOELECTRIC RECONSTRUCTION IN COMPUTED TOMOGRAPHY - PRELIMINARY-RESULTS [J].
AVRIN, DE ;
MACOVSKI, A ;
ZATZ, LM .
INVESTIGATIVE RADIOLOGY, 1978, 13 (03) :217-222
[3]
Hepatocellular carcinoma: Evaluation with biphasic, contrast-enhanced, helical CT [J].
Baron, RL ;
Oliver, JH ;
Dodd, GD ;
Nalesnik, M ;
Holbert, BL ;
Carr, B .
RADIOLOGY, 1996, 199 (02) :505-511
[4]
Estimated risks of radiation-induced fatal cancer from pediatric CT [J].
Brenner, DJ ;
Elliston, CD ;
Hall, EJ ;
Berdon, WE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :289-296
[5]
Clinical Utility of Dual-Energy CT in the Evaluation of Solitary Pulmonary Nodules: Initial Experience [J].
Chae, Eun Jin ;
Song, Jae-Woo ;
Seo, Joon Beom ;
Krauss, Bernhard ;
Jang, Yu Mi ;
Song, Koun-Sik .
RADIOLOGY, 2008, 249 (02) :671-681
[6]
Abdominal Aorta: Evaluation with Dual-Source Dual-Energy Multidetector CT after Endovascular Repair of Aneurysms-Initial Observations [J].
Chandarana, Hersh ;
Godoy, Myrna C. B. ;
Vlahos, Ioannis ;
Graser, Anno ;
Babb, James ;
Leidecker, Christianne ;
Macari, Michael .
RADIOLOGY, 2008, 249 (02) :692-700
[7]
First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[8]
Dose reduction and image quality in MDCT colonography using tube current modulation [J].
Graser, A. ;
Wintersperger, B. J. ;
Suess, C. ;
Reiser, M. F. ;
Becker, C. R. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (03) :695-701
[9]
GRASER A, 2009, RADIOLOGY
[10]
Dual energy CT: preliminary observations and potential clinical applications in the abdomen [J].
Graser, Anno ;
Johnson, Thorsten R. C. ;
Chandarana, Hersh ;
Macari, Michael .
EUROPEAN RADIOLOGY, 2009, 19 (01) :13-23