Dose reduction and image quality in MDCT colonography using tube current modulation

被引:81
作者
Graser, A.
Wintersperger, B. J.
Suess, C.
Reiser, M. F.
Becker, C. R.
机构
[1] Univ Munich, Dept Clin Radiol, D-81377 Munich, Germany
[2] Siemens Med Solut, CT Div, Forchheim, Germany
关键词
colonography; CT; dose reduction; MDCT; radiation dose; screening; tube current modulation;
D O I
10.2214/AJR.05.0662
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of our study was to evaluate the dose reduction potential of combined online (x- and y-axes) and topogram-based (1) X-ray tube current modulation in CT colonography in a screening population. MATERIALS AND METHODS. Eighty asymptomatic individuals underwent CT colonography screening for colon polyps. A 16-MDCT scanner (Somatom Sensation 16) was used. Forty patients were examined at 120 kVp and 120 effective mAs (supine) and 40 effective mAs (prone) using online x- and y-axis tube current modulation. Another 40 patients were scanned using combined x-, y-, and z-axis tube current modulation. Individual patient radiation exposure was determined using the dose-length product. Image noise was determined by Hounsfield unit measurements in the colonic lumen at four anatomic levels. Image quality was rated on a 5-point confidence scale by two independent reviewers. The impaired Student's t test (for radiation dose, image noise) and Wilcoxon's test (for image quality) were used to test for statistically significant differences between these values. RESULTS. Radiation dose was significantly lower in the patient group scanned with x-, y-, and z-axis tube current modulation than in the group scanned with x- and y-axis tube current modulation (supine: 4.24 vs 6.50 mSv, p < 0.0001; prone: 1.61 vs 2.38 mSv, p < 0.0001). Radiation dose was reduced by 35% (supine) and 33% (prone). No statistically significant difference was seen in overall image noise (supine: 15.9 vs 16.3 H, p = 0.13; prone: 23.5 vs 24. 8 H, p = 0.44) or image quality (supine: 4.6 vs 4.5, p = 0.62; prone: 3.5 vs 3.6, p = 0.54). CONCLUSION. Combined x-, y, and z-axis tube current modulation leads to a significant reduction of radiation exposure in CT colonography without loss of image quality.
引用
收藏
页码:695 / 701
页数:7
相关论文
共 26 条
  • [1] Becker C, 1999, ROFO-FORTSCHR RONTG, V170, P99
  • [2] BONGARTZ G, 1999, 16262EN EUR LUX OFF
  • [3] Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey
    Brix, G
    Nagel, HD
    Stamm, G
    Veit, R
    Lechel, U
    Griebel, J
    Galanski, M
    [J]. EUROPEAN RADIOLOGY, 2003, 13 (08) : 1979 - 1991
  • [4] Multi-slice CT-colonography in low-dose technique -: Preliminary results
    Cohnen, M
    Vogt, C
    Aurich, V
    Beck, A
    Häussinger, D
    Mödder, U
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (07): : 835 - 838
  • [5] Computed tomographic colonography (virtual colonoscopy) - A multicenter comparison with standard colonoscopy for detection of colorectal neoplasia
    Cotton, PB
    Durkalski, VL
    Benoit, PC
    Palesch, YY
    Mauldin, PD
    Hoffman, B
    Vining, DJ
    Small, WC
    Affronti, J
    Rex, D
    Kopecky, KK
    Ackerman, S
    Burdick, JS
    Brewington, C
    Turner, MA
    Zfass, A
    Wright, AR
    Iyer, RB
    Lynch, P
    Sivak, MV
    Butler, H
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2004, 291 (14): : 1713 - 1719
  • [6] Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose)
    Greess, H
    Nömayr, A
    Wolf, H
    Baum, U
    Lell, M
    Böwing, B
    Kalender, W
    Bautz, WA
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (06) : 1571 - 1576
  • [7] Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions
    Greess, H
    Wolf, H
    Baum, U
    Lell, M
    Pirkl, M
    Kalender, W
    Bautz, WA
    [J]. EUROPEAN RADIOLOGY, 2000, 10 (02) : 391 - 394
  • [8] Greess H, 1999, ROFO-FORTSCHR RONTG, V170, P246
  • [9] Detection of colorectal lesions: Lower-dose multi-detector row helical CT colonograph compared with conventional colonoscopy
    Iannaccone, R
    Laghi, A
    Catalano, C
    Brink, JA
    Mangiapane, F
    Trenna, S
    Piacentini, F
    Passariello, R
    [J]. RADIOLOGY, 2003, 229 (03) : 775 - 781
  • [10] Ultra-low-dose coronary artery calcium screening using multislice CT with retrospective ECG gating
    Jakobs, TF
    Wintersperger, BJ
    Herzog, P
    Flohr, T
    Suess, C
    Knez, A
    Reiser, MF
    Becker, CR
    [J]. EUROPEAN RADIOLOGY, 2003, 13 (08) : 1923 - 1930