Ultra-low-dose coronary artery calcium screening using multislice CT with retrospective ECG gating

被引:49
作者
Jakobs, TF
Wintersperger, BJ
Herzog, P
Flohr, T
Suess, C
Knez, A
Reiser, MF
Becker, CR
机构
[1] Univ Munich, Klinikum Grosshadern, Dept Clin Radiol, D-81377 Munich, Germany
[2] Siemens Med Solut, D-91301 Forchheim, Germany
[3] Univ Munich, Klinikum Grosshadern, Dept Cardiol, D-81377 Munich, Germany
关键词
X-ray computed tomography; heart; coronary vessels; phantoms; calcification;
D O I
10.1007/s00330-003-1895-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to reduce radiation exposure in multislice CT (MSCT) coronary artery calcium screening using different tube settings, and to determinate its impact on the detection and quantification of coronary artery calcification. Forty-eight patients underwent routine MSCT coronary artery calcium scoring (Somatom VolumeZoom, Siemens, Forchheim, Germany) with retrospective ECG-gated data acquisition. Scanning was performed with a 4x2.5-mm collimation. In each patient data acquisition was performed twice using tube settings of 120 kVp with 133 mAs (protocol 1) and of 80 kVp with 300 mAs (protocol 2). Together with the 80-kVp protocol additional online ECG-related tube current modulation (ECG pulsing) was used. Three-millimeter overlapping slices (increment 1.5 mm) were calculated for each data set. Semi-automated calcium quantification was performed calculating absolute Cahydroxylapatite mass. In addition to patient examinations, the radiation exposure for both protocols was evaluated using computed tomography dose index (CTDI) phantom measurements. Protocol 2 showed a significantly lower patient radiation exposure than protocol 1 (0.72 vs 2.04 mSv; p<0.0001). The CTDI phantom measurements revealed a 65% reduction of radiation dose. Calcium scoring results of both protocols showed a high correlation (r=0.99; p<0.0001) for absolute Ca-Hydroxylapatite mass measurements. Using 80-kVp protocols patient radiation exposure can be significantly reduced in MSCT coronary artery calcium screening without affecting the detection and quantification of coronary artery calcification; therefore, this technique should be used with retrospective ECG-gated cardiac CT examinations in patients with regular sinus rhythm.
引用
收藏
页码:1923 / 1930
页数:8
相关论文
共 20 条
  • [1] Becker C, 1999, ROFO-FORTSCHR RONTG, V170, P99
  • [2] Coronary artery calcium scoring: medicine and politics
    Becker, CR
    Schoepf, UJ
    Reiser, MF
    [J]. EUROPEAN RADIOLOGY, 2003, 13 (03) : 445 - 447
  • [3] Helical and single-slice conventional CT versus electron beam CT for the quantification of coronary artery calcification
    Becker, CR
    Jakobs, TF
    Aydemir, S
    Becker, A
    Knez, A
    Schoepf, UJ
    Bruening, R
    Haberl, R
    Reiser, MF
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) : 543 - 547
  • [4] Coronary artery calcium measurement: Agreement of multirow detector and electron beam CP
    Becker, CR
    Kleffel, T
    Crispin, A
    Knez, A
    Young, J
    Schoepf, UJ
    Haberl, R
    Reiser, MF
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (05) : 1295 - 1298
  • [5] Bongartz G, 1999, 16262 EUR EN
  • [6] Effect of HMG-Coa reductase inhibitors on coronary artery disease as assessed by electron-beam computed tomography
    Callister, TQ
    Raggi, P
    Cooil, B
    Lippolis, NJ
    Russo, DJ
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (27) : 1972 - 1978
  • [7] FRIEDEWALD ST, 1988, CECILS TXB MED, P179
  • [8] Coronary artery calcium measurement with multi-detector row CT: In vitro assessment of effect of radiation dose
    Hong, C
    Bae, KT
    Pilgram, TK
    Suh, J
    Bradley, D
    [J]. RADIOLOGY, 2002, 225 (03) : 901 - 906
  • [9] Technique factors and image quality as functions of patient weight at abdominal CT
    Huda, W
    Scalzetti, EM
    Levin, G
    [J]. RADIOLOGY, 2000, 217 (02) : 430 - 435
  • [10] Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation
    Jakobs, TF
    Becker, CR
    Ohnesorge, B
    Flohr, T
    Suess, C
    Schoepf, UJ
    Reiser, MF
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (05) : 1081 - 1086