Coronary artery calcium measurement with multi-detector row CT: In vitro assessment of effect of radiation dose

被引:47
作者
Hong, C
Bae, KT
Pilgram, TK
Suh, J
Bradley, D
机构
[1] Washington Univ, Sch Med, Edward Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
[2] Siemens Med Syst Inc, Iselin, NJ 08830 USA
关键词
computed tomography (CT); radiation exposure; coronary vessels; calcification; CT;
D O I
10.1148/radiol.2253011871
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors assessed in vitro the effect of radiation dose on coronary artery calcium quantification with multi-detector row computed tomography. A cardiac phantom with calcified cylinders was scanned at various milliampere second settings (20-160 mAs). A clear tendency was found for image noise to decrease as tube current increased (P < .001). No tendency was found for the Agatson score or calcium volume and mass errors to vary with tube current. Calcium measurements were not significantly affected by the choice of tube current. Calcium mass error was strongly correlated with calcium volume error (P < .001). The calcium mass measurement was more accurate and less variable than the calcium volume measurement. (C) RSNA, 2002.
引用
收藏
页码:901 / 906
页数:6
相关论文
共 25 条
  • [1] Achenbach S, 2001, CIRCULATION, V103, P2535
  • [2] QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY
    AGATSTON, AS
    JANOWITZ, WR
    HILDNER, FJ
    ZUSMER, NR
    VIAMONTE, M
    DETRANO, R
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) : 827 - 832
  • [3] Predictive value of electron beam computed tomography of the coronary arteries - 19-month follow-up of 1173 asymptomatic subjects
    Arad, Y
    Spadaro, LA
    Goodman, K
    LledoPerez, A
    Sherman, S
    Lerner, C
    Guerci, AD
    [J]. CIRCULATION, 1996, 93 (11) : 1951 - 1953
  • [4] Coronary artery calcium measurement: Agreement of multirow detector and electron beam CP
    Becker, CR
    Kleffel, T
    Crispin, A
    Knez, A
    Young, J
    Schoepf, UJ
    Haberl, R
    Reiser, MF
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (05) : 1295 - 1298
  • [5] SMALL LESIONS IN THE HEART IDENTIFIED AT ELECTRON-BEAM CT - CALCIFICATION OR NOISE
    BIELAK, LF
    KAUFMANN, RB
    MOLL, PP
    MCCOLLOUGH, CH
    SCHWARTZ, RS
    SHEEDY, PF
    [J]. RADIOLOGY, 1994, 192 (03) : 631 - 636
  • [6] Coronary artery disease: Improved reproducibility of calcium scoring with an electron-beam CT volumetric method
    Callister, TQ
    Cooil, B
    Raya, SP
    Lippolis, NJ
    Russo, DJ
    Raggi, P
    [J]. RADIOLOGY, 1998, 208 (03) : 807 - 814
  • [7] CHANLLANDE P, 1994, RADIOLOGY, V193, P282
  • [8] Prognostic significance of coronary calcific deposits in asymptomatic high-risk subjects
    Detrano, RC
    Wong, ND
    Doherty, TM
    Shavelle, R
    [J]. AMERICAN JOURNAL OF MEDICINE, 1997, 102 (04) : 344 - 349
  • [9] REPRODUCIBILITY OF THE MEASUREMENT OF CORONARY CALCIUM WITH ULTRAFAST COMPUTED-TOMOGRAPHY
    DEVRIES, S
    WOLFKIEL, C
    SHAH, V
    CHOMKA, E
    RICH, S
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (14) : 973 - 975
  • [10] Coronary artery calcium: Absolute quantification in nonenhanced and contrast-enhanced multi-detector row CT studies
    Hong, C
    Becker, CR
    Schoepf, UJ
    Ohnesorge, B
    Bruening, R
    Reiser, MF
    [J]. RADIOLOGY, 2002, 223 (02) : 474 - 480