Power spectral strain estimators in elastography

被引:58
作者
Konofagou, EE
Varghese, T
Ophir, J
Alam, SK
机构
[1] Univ Texas, Sch Med, Dept Radiol, Ultrason Lab, Houston, TX 77030 USA
[2] Univ Houston, Dept Elect Engn, Houston, TX 77004 USA
[3] Univ Houston, Biomed Engn Program, Houston, TX 77004 USA
关键词
bandwidth; centroid; cross correlation; elastogram; elastography; imaging; spectral shift; strain; strain filter; ultrasound;
D O I
10.1016/S0301-5629(99)00061-7
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Elastography can produce quality strain images in vitro and in vivo. Standard elastography uses a coherent cross-correlation technique to estimate tissue displacement and tissue strain using a subsequent gradient operator, Although coherent estimation methods generally have the advantage of being highly accurate and precise, even relatively small undesired motions are likely to cause enough signal decorrelation to produce significant degradation of the elastogram. For elastography to become more universally practical in such applications as hand-held, intravascular and abdominal imaging, the limitations associated with coherent strain estimation methods that require tissue and system stability, must be overcome. In this paper, we propose the use of a spectral-shift method that uses a centroid shift estimate to measure local strain directly. Furthermore, we also show theoretically that a spectral bandwidth method can also provide a direct strain estimation. We demonstrate that strain estimation using the spectral-shift technique is moderately less precise, but far more robust than the cross-correlation method. A theoretical analysis, simulations and experimental results are used to illustrate the properties associated with this method. (C) 1999 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1115 / 1129
页数:15
相关论文
共 62 条
[1]   Reduction of signal decorrelation from mechanical compression of tissues by temporal stretching: Applications to elastography [J].
Alam, SK ;
Ophir, J .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (01) :95-105
[2]   An adaptive strain estimator for elastography [J].
Alam, SK ;
Ophir, J ;
Konofagou, EE .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (02) :461-472
[3]  
ALAM SK, 1999, UNPUB IEEE T ULTRASO
[4]   OPTIMAL CENTER-FREQUENCY ESTIMATION FOR BACKSCATTERED ULTRASOUND PULSES [J].
BAHR, RK ;
BUCKLEW, JA ;
FLAX, SW .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1985, 32 (06) :809-814
[5]  
Bamber JC, 1996, ACOUST IMAG, V22, P285
[6]  
BENDAT JS, 1986, RANDOM DATA ANAL MEA, V142
[7]  
BERTRAND M, 1989, P IEEE ULTR S, P859
[8]   Deformation models and correlation analysis in elastography [J].
Bilgen, M ;
Insana, MF .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1996, 99 (05) :3212-3224
[9]   Error analysis in acoustic elastography .2. Strain estimation and SNR analysis [J].
Bilgen, M ;
Insana, MF .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 101 (02) :1147-1154
[10]  
Bracewell R., 1984, FOURIER TRANSFORM IT