Validation of a personalized dosimetric evaluation tool (Oedipe) for targeted radiotherapy based on the Monte Carlo MCNPX code

被引:53
作者
Chiavassa, S
Aubineau-Lanièce, I
Bitar, A
Lisbona, A
Barbet, J
Franck, D
Jourdain, JR
Bardiès, M
机构
[1] INSERM, French Inst Hlth & Med Res, U601, F-44000 Nantes, France
[2] CEA, French Atom Energy Commissariat, DRT, LIST,DETECTS,LNHB, F-91191 Gif Sur Yvette, France
[3] LEDI, IRSN, DRPH, SDI,French Inst Radiat Protect & Nucl Safety, F-92262 Fontenay Aux Roses, France
关键词
D O I
10.1088/0031-9155/51/3/009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dosimetric studies are necessary for all patients treated with targeted radiotherapy. In order to attain the precision required, we have developed Oedipe, a dosimetric tool based on the MCNPX Monte Carlo code. The anatomy of each patient is considered in the form of a voxel-based geometry created using computed tomography (CT) images or magnetic resonance imaging (MRI). Oedipe enables dosimetry studies to be carried out at the voxel scale. Validation of the results obtained by comparison with existing methods is complex because there are multiple sources of variation: calculation methods (different Monte Carlo codes, point kernel), patient representations (model or specific) and geometry definitions (mathematical or voxel-based). In this paper, we validate Oedipe by taking each of these parameters into account independently. Monte Carlo methodology requires long calculation times, particularly in the case of voxel-based geometries, and this is one of the limits of personalized dosimetric methods. However, our results show that the use of voxel-based geometry as opposed to a mathematically defined geometry decreases the calculation time two-fold, due to an optimization of the MCNPX2.5e code. It is therefore possible to envisage the use of Oedipe for personalized dosimetry in the clinical context of targeted radiotherapy.
引用
收藏
页码:601 / 616
页数:16
相关论文
共 31 条
[1]  
[Anonymous], 1975, MIRD PAMPHLET
[2]   Dosimetry and microdosimetry of targeted radiotherapy [J].
Bardiès, M ;
Pihet, P .
CURRENT PHARMACEUTICAL DESIGN, 2000, 6 (14) :1469-1502
[3]  
Bergstrom J., 1968, Geologica et Palaeontologica Marbourg, V2, P1
[4]  
Briesmeister JF., 1997, ALAMOS NATL LAB REPO, pLA
[5]   Voxel-based computational models of real human anatomy: a review [J].
Caon, M .
RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2004, 42 (04) :229-235
[6]   OEDIPE:: A personalized dosimetric tool associating voxel-based models with MCNPX [J].
Chiavassa, S ;
Bardiès, M ;
Guiraud-Vitaux, F ;
Bruel, D ;
Jourdain, JR ;
Franck, D ;
Aubineau-Lanièce, I .
CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2005, 20 (03) :325-332
[7]  
CHIAVASSA S, 2005, RADIAT PROT DOSIM, V113, P1
[8]  
CHIVASSA S, 2006, UNPUB AMCTM BOOK 7
[9]   Improvement of internal dose calculations using mathematical models of different adult heights [J].
Clairand, I ;
Bouchet, LG ;
Ricard, M ;
Durigon, M ;
Di Paola, M ;
Aubert, B .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (10) :2771-2785
[10]  
CRISTYS M, 1987, ORNLNUREGTM83816