Voxel-based computational models of real human anatomy: a review

被引:138
作者
Caon, M [1 ]
机构
[1] Flinders Univ S Australia, Sch Nursing & Midwifery, Adelaide, SA 5001, Australia
关键词
D O I
10.1007/s00411-003-0221-8
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Computational models of human anatomy are mathematical representations of human anatomy designed to be used in dosimetry calculations. They have been used in dosimetry calculations for radiography, radiotherapy, nuclear medicine, radiation protection and to investigate the effects of low frequency electromagnetic fields. Tomographic medical imaging techniques have allowed the construction of digital three-dimensional computational models based on the actual anatomy of individual humans. These are called voxel models, tomographic models or phantoms. Their usefulness lies in their faithful representation of human anatomy and the flexibility they afford by being able to be scaled in size to match the required human dimensions. Segmenting medical images in order to make voxel models is very time-consuming so semi-automatic segmentation techniques are being developed. Some 21 whole or partial body models currently exist and more are being prepared. These models are listed and discussed.
引用
收藏
页码:229 / 235
页数:7
相关论文
共 54 条
[1]  
[Anonymous], 1980, MATH PHANTOMS REPRES
[2]  
[Anonymous], 1991, 1990 recommendations of the international commission on radiological protection ICRP publication 60
[3]   An EGS4-ready tomographic computational model of a 14-year-old female torso for calculating organ doses from CT examinations [J].
Caon, M ;
Bibbo, G ;
Pattison, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (09) :2213-2225
[4]   Monte Carlo calculated effective dose to teenage girls from computed tomography examinations [J].
Caon, M ;
Bibbo, G ;
Pattison, J .
RADIATION PROTECTION DOSIMETRY, 2000, 90 (04) :445-448
[5]  
CAON M, 2001, AUSTRALAS PHYS ENG S, V24, P166
[6]   Conversion coefficients based on the VIP-MAN anatomical model and EGS4-VLSI code for external monoenergetic photons from 10 keV to 10 MeV [J].
Chao, TC ;
Bozkurt, A ;
Xu, XG .
HEALTH PHYSICS, 2001, 81 (02) :163-183
[7]   Specific absorbed fractions from the image-based VIP-Man body model and EGS4-VLSI Monte Carlo code: internal electron emitters [J].
Chao, TC ;
Xu, XG .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (04) :901-927
[8]  
Chen WL, 1978, EVALUATION DISTRIBUT
[9]   FDTD calculations of the whole-body averaged SAR in an anatomically realistic voxel model of the human body from 1 MHz to 1 GHz [J].
Dimbylow, PJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (03) :479-490
[10]   Fine resolution calculations of SAR in the human body for frequencies up to 3 GHz [J].
Dimbylow, PJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (16) :2835-2846