Conversion coefficients based on the VIP-MAN anatomical model and EGS4-VLSI code for external monoenergetic photons from 10 keV to 10 MeV

被引:78
作者
Chao, TC
Bozkurt, A
Xu, XG
机构
[1] Rensselaer Polytech Inst, Nucl Engn Program, Troy, NY 12180 USA
[2] Rensselaer Polytech Inst, Engn Phys Program, Troy, NY 12180 USA
[3] Harran Univ, Fac Arts & Sci, Dept Phys, TR-63200 Sanliurfa, Turkey
来源
HEALTH PHYSICS | 2001年 / 81卷 / 02期
关键词
phantom; photons; Monte Carlo; dose;
D O I
10.1097/00004032-200108000-00010
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A new set of conversion coefficients from kerma free-in-air to absorbed dose and kerma free-in-air to "effective VIP-Man dose" has been calculated for external monoenergetic photon beams from 10 keV to 10 MeV using an image-based whole-body anatomical model. This model, called VIP-Man, was recently developed at Rensselaer from the high-resolution color images of the National Library of Medicine's Visible Human Project. An EGS4-based Monte Carlo user code, named EGS4-VLSI, was developed to efficiently process the extremely large image data in VIP-Man. Irradiation conditions include anterior-posterior, posterior-anterior, right lateral, left lateral, rotational, and isotropic geometries. Conversion coefficients from this study are compared with those obtained from two mathematical models, ADAM and EVA. "Effective VIP-Man doses" differ from the previously reported effective dose results by 10%-50% for photons between 100 keV and 10 MeV. Discrepancies are more significant at lower energies and for individual organ doses. Since VIP-Man is a realistic model that contains several tissues that were not previously defined well (or not available) in other models, the reported results offer an opportunity to improve the existing dosimetric data and the mathematical models.
引用
收藏
页码:163 / 183
页数:21
相关论文
共 45 条
[1]  
Ackerman M J., 1995, D-Lib Magazine, V1, DOI 10.1045/october95-ackerman
[2]  
[Anonymous], ICRP PUBL
[3]  
[Anonymous], 1979, ICRP PUBL
[4]  
[Anonymous], ICRP PUBL
[5]  
[Anonymous], 1994, HUM RESP TRACT MOD R
[6]   MEASUREMENTS OF TRABECULAR BONE-STRUCTURE IN MAN [J].
BEDDOE, AH ;
DARLEY, PJ ;
SPIERS, FW .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (04) :589-607
[7]   Fluence-to-dose conversion coefficients from monoenergetic neutrons below 20 MeV based on the VIP-Man anatomical model [J].
Bozkurt, A ;
Chao, TC ;
Xu, XG .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (10) :3059-3079
[8]   Fluence-to-dose conversion coefficients based on the VIP-MAN anatomical model and mcnpx code for monoenergetic neutrons above 20 MeV [J].
Bozkurt, A ;
Chao, TC ;
Xu, XG .
HEALTH PHYSICS, 2001, 81 (02) :184-202
[9]   An EGS4-ready tomographic computational model of a 14-year-old female torso for calculating organ doses from CT examinations [J].
Caon, M ;
Bibbo, G ;
Pattison, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (09) :2213-2225
[10]   Organ dose conversion coefficients for 0.1-10 MeV electrons calculated for the VIP-MAN tomographic model [J].
Chao, TC ;
Bozkurt, A ;
Xu, XG .
HEALTH PHYSICS, 2001, 81 (02) :203-214