Fluence-to-dose conversion coefficients based on the VIP-MAN anatomical model and mcnpx code for monoenergetic neutrons above 20 MeV

被引:38
作者
Bozkurt, A
Chao, TC
Xu, XG
机构
[1] Rensselaer Polytech Inst, Nucl Engn Program, Troy, NY 12180 USA
[2] Rensselaer Polytech Inst, Engn Phys Program, Troy, NY 12180 USA
[3] Harran Univ, Fac Arts & Sci, Dept Phys, TR-63200 Sanliurfa, Turkey
来源
HEALTH PHYSICS | 2001年 / 81卷 / 02期
关键词
phantom; neutrons; Monte Carlo; dose;
D O I
10.1097/00004032-200108000-00011
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A new set of fluence-to-absorbed dose and fluence-to-effective dose conversion coefficients has been calculated for high-energy neutrons using a whole-body anatomical model, VIP-Man, developed from the high-resolution transversal color photographic images of the National Library of Medicine's Visible Human Project, Organ dose calculations were performed using the Monte Carlo code MCNPX for 20 monoenergetic neutron beams between 20 MeV and 10,000 MeV under 6 different irradiation geometries: anterior-posterior, posterior-anterior, left lateral, right lateral, isotropic, and rotational. For neutron Monte Carlo calculations, results based on an image-based whole-body model were not available in the literature. The absorbed dose results for 24 major organs of VIP-Man are presented in the form of tables and selected figures that compare with those based on simplified mathematical phantoms reported in the literature. VIP-Man yields up to 40% Larger values of effective dose and many organ doses, thus suggesting that the results reported in the past may not be conservative.
引用
收藏
页码:184 / 202
页数:19
相关论文
共 43 条
[1]   ABSORBED DOSE AND DOSE EQUIVALENT FROM NEUTRONS IN ENERGY RANGE 60 TO 3000 MEV AND PROTONS IN ENERGY RANGE 400 TO 3000 MEV [J].
ALSMILLER, RG ;
ARMSTRONG, TW ;
COLEMAN, WA .
NUCLEAR SCIENCE AND ENGINEERING, 1970, 42 (03) :367-+
[2]  
*AM NUCL SOC, 1991, ANSANS611
[3]   Dosimetry for occupational exposure to cosmic radiation [J].
Bartlett, DT ;
McAulay, IR ;
Schrewe, UJ ;
Schnuer, K ;
Menzel, HG ;
BottollierDepois, JF ;
Dietze, G ;
Gmur, K ;
Grillmaeir, RE ;
Heinrich, W ;
Lim, T ;
Lindborg, L ;
Reitz, G ;
Schraube, H ;
Spurny, F ;
Tommasino, L .
RADIATION PROTECTION DOSIMETRY, 1997, 70 (1-4) :395-404
[4]   INTRANUCLEAR-CASCADE CALCULATION OF SECONDARY NUCLEON SPECTRA FROM NUCLEON-NUCLEUS INTERACTIONS IN ENERGY RANGE 340 TO 2900 MEV AND COMPARISONS WITH EXPERIMENT [J].
BERTINI, HW .
PHYSICAL REVIEW, 1969, 188 (04) :1711-&
[5]   Fluence-to-dose conversion coefficients from monoenergetic neutrons below 20 MeV based on the VIP-Man anatomical model [J].
Bozkurt, A ;
Chao, TC ;
Xu, XG .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (10) :3059-3079
[6]  
Briesmeister JF., 1997, ALAMOS NATL LAB REPO, pLA
[7]   An EGS4-ready tomographic computational model of a 14-year-old female torso for calculating organ doses from CT examinations [J].
Caon, M ;
Bibbo, G ;
Pattison, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (09) :2213-2225
[8]   Cross-section evaluations to 150 MeV for accelerator-driven systems and implementation in MCNPX [J].
Chadwick, MB ;
Young, PG ;
Chiba, S ;
Frankle, SC ;
Hale, GM ;
Hughes, HG ;
Koning, AJ ;
Little, RC ;
MacFarlane, RE ;
Prael, RE ;
Waters, LS .
NUCLEAR SCIENCE AND ENGINEERING, 1999, 131 (03) :293-328
[9]   Conversion coefficients based on the VIP-MAN anatomical model and EGS4-VLSI code for external monoenergetic photons from 10 keV to 10 MeV [J].
Chao, TC ;
Bozkurt, A ;
Xu, XG .
HEALTH PHYSICS, 2001, 81 (02) :163-183
[10]   Organ dose conversion coefficients for 0.1-10 MeV electrons calculated for the VIP-MAN tomographic model [J].
Chao, TC ;
Bozkurt, A ;
Xu, XG .
HEALTH PHYSICS, 2001, 81 (02) :203-214