Effects of interfacial layer wettability and thickness on the coating morphology and sirolimus release for drug-eluting stent

被引:24
作者
Bedair, Tarek M. [1 ,2 ,3 ]
Yu, Seung Jung [4 ,5 ]
Im, Sung Gap [4 ,5 ]
Park, Bang Ju [6 ,7 ]
Joung, Yoon Ki [1 ,2 ]
Han, Dong Keun [1 ,2 ]
机构
[1] Korea Inst Sci & Technol, Biomed Res Inst, Ctr Biomat, Seoul 136791, South Korea
[2] Korea Univ Sci & Technol, Dept Biomed Engn, Daejeon 305333, South Korea
[3] Menia Univ, Dept Chem, Fac Sci, El Minia 61519, Egypt
[4] Korea Adv Inst Sci & Technol, Dept Chem & Biomol Engn, Daejeon 305701, South Korea
[5] Korea Adv Inst Sci & Technol, Graphene Res Ctr, KI NanoCentury, Daejeon 305701, South Korea
[6] Gachon Univ, Dept Elect Engn, Gyeonggi 146701, South Korea
[7] Gachon Univ, Inst Gachon Fus Technol, Gyeonggi 146701, South Korea
关键词
Drug-eluting stent; Biodegradable polymer; Ring-opening polymerization; Photo-initiated chemical vapor deposition; Polymer brush; CHEMICAL-VAPOR-DEPOSITION; IN-VITRO DEGRADATION; POLY(2-HYDROXYETHYL METHACRYLATE); SURFACE; TITANIUM; THROMBOGENICITY; IMPLANTATION; DURABILITY; MONOLAYERS; STABILITY;
D O I
10.1016/j.jcis.2015.08.051
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070305 [高分子化学与物理];
摘要
Drug-eluting stents (DESs) have been used to treat coronary artery diseases by placing in the arteries. However, current DESs still suffer from polymer coating defects such as delamination and peeling-off that follows stent deployment. Such coating defects could increase the roughness of DES and might act as a source of late or very late thrombosis and might increase the incident of restenosis. In this regard, we modified the cobalt-chromium (Co-Cr) alloy surface with hydrophilic poly(2-hydroxyethyl methacrylate) (PHEMA) or hydrophobic poly(2-hydroxyethyl methacrylate)-grafted-poly(caprolactone) (PHEMA-g-PCL) brushes. The resulting surfaces were biocompatible and biodegradable, which could act as anchoring layer for the drug-in-polymer matrix coating. The two modifications were characterized by ATR-FTIR, XPS, water contact angle measurements, SEM and AFM. On the control and modified Co-Cr samples, a sirolimus (SRL)-containing poly(D,L-lactide) (PDLLA) were ultrasonically spray-coated, and the drug release was examined for 8 weeks under physiological conditions. The results demonstrated that PHEMA as a primer coating improved the coating stability and degradation morphology, and drug release profile for short-term as compared to control Co-Cr, but fails after 7 weeks in physiological buffer. On the other hand, the hydrophobic PHEMA-g-PCL brushes not only enhanced the stability and degradation morphology of the PDLLA coating layer, but also sustained SRL release for long-term. At 8-week of release test, the surface morphologies and release profiles of coated PDLLA layers verified the beneficial effect of hydrophobic PCL brushes as well as their thickness on coating stability. Our study concludes that 200 nm thickness of PHEMA-g-PCL as interfacial layer affects the stability and degradation morphology of the biodegradable coating intensively to be applied for various biodegradable-based DESs. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:189 / 199
页数:11
相关论文
共 53 条
[1]
Synthesis and characterization of biocompatible polymer interlayers on titanium implant materials [J].
Adden, Nina ;
Gamble, Lara J. ;
Castner, David G. ;
Hoffmann, Andrea ;
Gross, Gerhard ;
Menzel, Henning .
BIOMACROMOLECULES, 2006, 7 (09) :2552-2559
[2]
Phosphonic acid monolayers for binding of bioactive molecules to titanium surfaces [J].
Adden, Nina ;
Gamble, Lara J. ;
Castner, David G. ;
Hoffmann, Andrea ;
Gross, Gerhard ;
Menzel, Henning .
LANGMUIR, 2006, 22 (19) :8197-8204
[3]
Surface properties of Reactive Yellow 2 immobilised pHEMA and HEMA/chitosan membranes:: characterisation of their selectivity to different proteins [J].
Arica, MY ;
Yilmaz, M ;
Yalçin, E ;
Bayramoglu, G .
JOURNAL OF MEMBRANE SCIENCE, 2004, 240 (1-2) :167-178
[4]
Polymer coatings on drug-eluting stents: Samson's hair and Achilles' heel? [J].
Basalus, Mounir W. Z. ;
Joner, Michael ;
von Birgelen, Clemens ;
Byrne, Robert A. .
EUROINTERVENTION, 2013, 9 (03) :302-305
[5]
Scanning electron microscopic assessment of the biodegradable coating on expanded biolimus-eluting stents [J].
Basalus, Mounir W. Z. ;
van Houwelingen, K. Gert ;
Ankone, Marc ;
de Man, Frits H. A. F. ;
von Birgelen, Clemens .
EUROINTERVENTION, 2009, 5 (04) :505-510
[6]
Bedair T.M., 2014, BIOMATERIALS BIOMEDI, V1, P121, DOI 10.12989/bme.2014.1.3.121
[7]
Biodegradable polymer brush as nanocoupled interface for improving the durability of polymer coating on metal surface [J].
Bedair, Tarek M. ;
Cho, Youngjin ;
Joung, Yoon Ki ;
Han, Dong Keun .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2014, 122 :808-817
[8]
Reinforcement of Interfacial Adhesion of a Coated Polymer Layer on a Cobalt-Chromium Surface for Drug-Eluting Stents [J].
Bedair, Tarek M. ;
Cho, Youngjin ;
Kim, Tae Jung ;
Kim, Young Dong ;
Park, Bang Ju ;
Joung, Yoon Ki ;
Han, Dong Keun .
LANGMUIR, 2014, 30 (27) :8020-8028
[9]
Initiated Chemical Vapor Deposition (iCVD) of Hydrogel Polymers [J].
Bose, R. K. ;
Nejati, S. ;
Lau, K. K. S. .
EUROCVD 17 / CVD 17, 2009, 25 (08) :1229-1235
[10]
Initiated CVD of Poly(2-Hydroxyethyl Methacrylate) Hydrogels: Synthesis, Characterization and In-vitro Biocompatibility [J].
Bose, Ranjita K. ;
Lau, Kenneth K. S. .
CHEMICAL VAPOR DEPOSITION, 2009, 15 (4-6) :150-155