Comparison of the brain penetration injury associated with microdialysis and voltammetry

被引:73
作者
Jaquins-Gerstl, Andrea [1 ]
Michael, Adrian C. [1 ]
机构
[1] Univ Pittsburgh, Dept Chem, Pittsburgh, PA 15260 USA
关键词
Microdialysis; Voltammetry; Penetration injury; Ischemia; GFAP; STRIATAL DOPAMINE RELEASE; RAT NUCLEUS-ACCUMBENS; FREELY MOVING RATS; IN-VIVO; EXTRACELLULAR DOPAMINE; PARKINSONS-DISEASE; EVOKED RELEASE; PROBES; IMPLANTATION; GLUTAMATE;
D O I
10.1016/j.jneumeth.2009.06.023
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
Emerging evidence suggests that differences between microdialysis- and voltammetry-based estimates of extracellular dopamine in the brain might originate in the different penetration injury associated with each technique. To address this issue in a direct fashion, microdialysis probes and voltammetric microelectrodes were implanted in the rat striatum for 1, 4, or 24 h. Tissues were perfused with a suspension of fluorescently labeled nanobeads to assess blood vessels near the implant. Tissue sections (30 mu m) were labeled with antibodies for PECAM, an endothelial cell marker, or GFAP, a glial marker. In non-implanted control tissue, blood vessels were reliably double-labeled with nanobeads and antiPECAM. Tissue near microdialysis probe tracks exhibited ischemia in the form of PECAM immunoreactive blood vessels devoid of nanobeads. Ischemia, was most apparent after the 4-h implants. Probe tracks were surrounded by endothelial cell debris, which appeared as a diffuse halo of PECAM immunoreactivity. The halo intensity decreased with implant duration, indicative of an active wound-healing process. Consistent with this, after 24-h implants, the probe tracks were surrounded by hyperplasic and hypertrophic glia and glial processes were extending towards, and engulfing, the track. Carbon fiber microelectrodes produced a diffuse disruption of nanobead labeling but no focal disruption of blood vessels, no PECAM immunoreactive halo, and no glial activation. These findings illuminate the differences between the extent and nature of the penetration injuries associated with microdialysis and voltammetry. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:127 / 135
页数:9
相关论文
共 60 条
[1]
REGIONAL CEREBRAL GLUCOSE PHOSPHORYLATION AND BLOOD-FLOW AFTER INSERTION OF A MICRODIALYSIS FIBER THROUGH THE DORSAL HIPPOCAMPUS IN THE RAT [J].
BENVENISTE, H ;
DREJER, J ;
SCHOUSBOE, A ;
DIEMER, NH .
JOURNAL OF NEUROCHEMISTRY, 1987, 49 (03) :729-734
[2]
CELLULAR REACTIONS TO IMPLANTATION OF A MICRODIALYSIS TUBE IN THE RAT HIPPOCAMPUS [J].
BENVENISTE, H ;
DIEMER, NH .
ACTA NEUROPATHOLOGICA, 1987, 74 (03) :234-238
[3]
Bignami A., 1980, ADV CELL NEUROBIOL, V1, P285
[4]
Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays [J].
Biran, R ;
Martin, DC ;
Tresco, PA .
EXPERIMENTAL NEUROLOGY, 2005, 195 (01) :115-126
[5]
Voltammetric study of extracellular dopamine near microdialysis probes acutely implanted in the striatum of the anesthetized rat [J].
Borland, LM ;
Shi, GY ;
Yang, H ;
Michael, AC .
JOURNAL OF NEUROSCIENCE METHODS, 2005, 146 (02) :149-158
[6]
Voltammetric study of the control of striatal dopamine release by glutamate [J].
Borland, LM ;
Michael, AC .
JOURNAL OF NEUROCHEMISTRY, 2004, 91 (01) :220-229
[7]
Microdialysis of dopamine interpreted with quantitative model incorporating probe implantation trauma [J].
Bungay, PM ;
Newton-Vinson, P ;
Isele, W ;
Garris, PA ;
Justice, JB .
JOURNAL OF NEUROCHEMISTRY, 2003, 86 (04) :932-946
[8]
An ultrastructural analysis of tissue surrounding a microdialysis probe [J].
Clapp-Lilly, KL ;
Roberts, RC ;
Duffy, LK ;
Irons, KP ;
Hu, Y ;
Drew, KL .
JOURNAL OF NEUROSCIENCE METHODS, 1999, 90 (02) :129-142
[9]
The biochemistry of Parkinson's disease [J].
Cookson, MR .
ANNUAL REVIEW OF BIOCHEMISTRY, 2005, 74 :29-52
[10]
Heterogeneity of electrically evoked dopamine release and reuptake in substantia nigra, ventral tegmental area, and striatum [J].
Cragg, SJ ;
Rice, ME ;
Greenfield, SA .
JOURNAL OF NEUROPHYSIOLOGY, 1997, 77 (02) :863-873