Amperometric detection of uric acid and hypoxanthine with Xanthine oxidase immobilized and carbon based screen-printed electrode. Application for fish freshness determination

被引:52
作者
Carsol, MA
Volpe, G
Mascini, M
机构
[1] DIPARTIMENTO SANITA PUBBL EPIDEMIOL & CHIM ANALIT,SEZ CHIM ANALIT,I-50121 FLORENCE,ITALY
[2] IST SUPER SANITA,LAB ALIMENTI,I-00161 ROME,ITALY
关键词
screen-printed electrodes; uric acid detection; xanthine oxidase; hypoxanthine detection; fish freshness;
D O I
10.1016/S0039-9140(97)00098-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Carbon-based screen-printed electrodes are suitable for uric acid detection. Xanthine oxidase (XO) was immobilized either directly on the surface of the electrode or in a reactor with CPG aminopropylsilane in a FIA assembly. Higher reproducibility and lifetime was obtained with the reactor. Optimum conditions were found for the determination of Hypoxanthine (Hx), Inosine (HxR) and Inosine monophosphate (IMP). Calibration curves for IMP, HxR and Hx are linear up to 50 mu M with detection limit of 1 mu M for 50 mu l injection. One assay is completed within 30 s. The reproducibility of 20 mu M of Hx was obtained with CV 2%. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:2151 / 2159
页数:9
相关论文
共 20 条
  • [1] DISPOSABLE RUTHENIZED SCREEN-PRINTED BIOSENSORS FOR PESTICIDES MONITORING
    CAGNINI, A
    PALCHETTI, I
    LIONTI, I
    MASCINI, M
    TURNER, APF
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1995, 24 (1-3) : 85 - 89
  • [2] EHIRA S, 1970, NIPPON SUISAN GAKK, V36, P491
  • [3] GONZALEZ E, 1992, ANAL CHIM ACTA, V242, P267
  • [4] SIMULTANEOUS VOLTAMMETRIC DETERMINATION OF HYPOXANTHINE, XANTHINE, AND URIC-ACID
    GOYAL, RN
    MITTAL, A
    SHARMA, S
    [J]. ELECTROANALYSIS, 1994, 6 (07) : 609 - 611
  • [5] CHEMICALLY AMPLIFIED XANTHINE AND HYPOXANTHINE SENSORS BASED ON SUBSTRATE RECYCLING BETWEEN THE ENZYME-SUBSTRATE COMPLEX AND SUBSTRATE
    HASEBE, Y
    GOKAN, A
    UCHIYAMA, S
    [J]. ANALYTICA CHIMICA ACTA, 1995, 302 (01) : 21 - 27
  • [6] MICROBIAL SENSOR SYSTEM FOR NONDESTRUCTIVE EVALUATION OF FISH MEAT QUALITY
    HOSHI, M
    SASAMOTO, Y
    NONAKA, M
    TOYAMA, K
    WATANABE, E
    [J]. BIOSENSORS & BIOELECTRONICS, 1991, 6 (01) : 15 - 20
  • [7] DETERMINATION OF FISH FRESHNESS WITH AN ENZYME SENSOR SYSTEM
    KARUBE, I
    MATSUOKA, H
    SUZUKI, S
    WATANABE, E
    TOYAMA, K
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1984, 32 (02) : 314 - 319
  • [8] KIM JM, 1989, BIOSENSORS APPL MED, P13
  • [9] LEE EH, 1982, B JPN SOC SCI FISH, V48, P255
  • [10] DEVELOPMENT AND APPLICATION OF A BIOSENSOR FOR HYPOXANTHINE IN FISH EXTRACT
    MULCHANDANI, A
    LUONG, JHT
    MALE, KB
    [J]. ANALYTICA CHIMICA ACTA, 1989, 221 (02) : 215 - 222