Comparison of dry, wet and microwave digestion procedures for the determination of chemical elements in wool samples in Turkey using ICP-OES technique

被引:36
作者
Aydin, Isil [1 ]
机构
[1] Dicle Univ, Fac Sci & Art, Dept Chem, TR-21280 Diyarbakir, Turkey
关键词
digestion; analysis; wool; ICP-OES; AAS;
D O I
10.1016/j.microc.2008.03.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The aim of this study is to quantify the content of elements (Co, Ni, Zn, Cu, Mn, Cd, Pb Cr, Fe, Na. K, Ca, Mg) present in wool samples (n:87) from Turkey because similar studies have not been published earlier. A fast and simple method for quantification of the metal content of wool samples was standardized for the three sample digestion procedures using dry ashing, wet ashing and microwave digestion and compared by the flame atomic absorption spectrometry (FAAS) and inductively coupled plasma-optical emission spectrometry (ICP-OES). The proposed method indicated satisfactory recovery, detection limits and standard deviation for trace metal determination in wool samples. The results in the samples (minimum-maximum in mu g g(-1)) were: Co 1.22-1.54, Cu 2.45-3.64, Min 0.44-0.65, Cd 0.08-0.30, Pb 1.33-1.74, Cr 0.33-1.25, Zn 73.94-87.08 and Fe 119.04-182.52. The lowest and highest levels of Na 0.31-0.37, K 0.05-0.06, Ca 0.50-0.66, Mg 0.11-0.12 were found as %. The concentration of Ni was below detection limit. The Certified Reference Material, CRM 397. Human Hair and Tomato Leaves-1573a were used in order to verify the accuracy of the microwave digestion method, and whether the results were in good agreement with the certified values. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:82 / 87
页数:6
相关论文
共 52 条
[11]  
CARLOS G, 1999, TALANTA, V48, P537
[12]   Diagnostic potential of hair analysis as applied to the Goldsmith sector [J].
Caroli, S ;
Senofonte, O ;
Violante, N ;
D'Ilio, S ;
Caimi, S ;
Chiodo, F ;
Menditto, A .
MICROCHEMICAL JOURNAL, 1998, 59 (01) :32-44
[13]   ONLINE PRECONCENTRATION AND DETERMINATION OF TRACE-ELEMENTS BY FLOW-INJECTION INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
CAROLI, S ;
ALIMONTI, A ;
PETRUCCI, F ;
HORVATH, Z .
ANALYTICA CHIMICA ACTA, 1991, 248 (01) :241-249
[14]   On-line preconcentration/determination of cadmium in drinking water on activated carbon using 8-hydroxyquinoline in a flow injection system coupled to an inductively coupled plasma optical emission spectrometer [J].
Cerutti, S ;
Silva, MF ;
Gásquez, JA ;
Olsina, RA ;
Martinez, LD .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (01) :43-50
[15]  
CHICCO CF, 1973, J ANIM SCI, V36, P986
[16]   MINERAL CONCENTRATIONS IN HAIR AS INDICATORS OF MINERAL STATUS - A REVIEW [J].
COMBS, DK ;
GOODRICH, RD ;
MEISKE, JC .
JOURNAL OF ANIMAL SCIENCE, 1982, 54 (02) :391-398
[17]   HAIR ANALYSIS AS AN INDICATOR OF MINERAL STATUS OF LIVESTOCK [J].
COMBS, DK .
JOURNAL OF ANIMAL SCIENCE, 1987, 65 (06) :1753-1758
[18]   Occupational exposure of goldsmith workers of the area of Rome to potentially toxic metals as monitored through hair analysis [J].
D'Ilio, S ;
Violante, N ;
Senofonte, O ;
Caroli, S .
MICROCHEMICAL JOURNAL, 2000, 67 (1-3) :343-349
[19]   Simple method for the accurate determination of selenium in serum by using inductively coupled plasma mass spectrometry [J].
Delves, HT ;
Sieniawska, CE .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (03) :387-389
[20]  
ERDOGAN S, 2003, ANKARA U J VET FACUL, V50, P1