Methodological parameters influence the detection of right-to-left shunts by contrast transcranial Doppler ultrasonography

被引:71
作者
Schwarze, JJ
Sander, D
Kukla, C
Wittich, I
Babikian, VL
Klingelhöfer, J
机构
[1] Tech Univ Munich, Dept Neurol, D-81675 Munich, Germany
[2] Boston Univ, Sch Med, Dept Neurol, Boston, MA 02118 USA
关键词
contrast media; embolism; paradoxical; foramen ovale; patent; heart septal defects; ultrasonography; Doppler; transcranial;
D O I
10.1161/01.STR.30.6.1234
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-Contrast transcranial Doppler ultrasonography is a new method to detect intracardiac right-to-left shunts, such as the patent foramen ovale. However, the methodology of the procedure varies considerably among investigators. This study was undertaken to assess the influence of methodological parameters on the results of the contrast transcranial Doppler examination in the detection of right-to-left shunts. Methods-A total of 72 patients (mean age, 58.2+/-14.7 years) had a contrast transcranial Doppler ultrasonography examination. To study the influence of methodological factors, patients with evidence of a right-to-left shunt underwent repeated examinations with modified procedures. Parameters under investigation were the timing of the Valsalva maneuver, the dose of the contrast medium, and the patient's posture during the examination. Results-The median contrast signal count was 58.5 and 48.0 (P<0.001) and the median latency of the first intracranially detected contrast signal was 12.5 and 8.5 seconds (P=0.05) when the Valsalva maneuver was performed 5 and 0 seconds after the start of the injection, respectively. Reducing the contrast medium dose from 10 to 5, 2.5, and 1.2 mt resulted in a decline of the median signal count from 54.5 to 28.5, 20.5, and 12.0 (P<0.01), respectively, while the latency of the first contrast signal increased from 13.3 to 14.0, 14.6, and 15.0 seconds (P<0.05). The sitting position also produced a lower signal count than the supine position (P<0.02). Conclusions-This study demonstrates that several essential methodological parameters influence the results of the contrast transcranial Doppler ultrasonography examination. Therefore, it is necessary to standardize the procedure to permit comparable quantitative assessments of the shunt volume. The findings of the present study suggest that 10 mi, of contrast medium be injected with the patient in the supine position and that the Valsalva maneuver be performed 5 seconds after the start of the injection.
引用
收藏
页码:1234 / 1239
页数:6
相关论文
共 36 条
  • [1] EVALUATION OF CEREBROVASCULAR SPASM WITH TRANSCRANIAL DOPPLER ULTRASOUND
    AASLID, R
    HUBER, P
    NORNES, H
    [J]. JOURNAL OF NEUROSURGERY, 1984, 60 (01) : 37 - 41
  • [2] COMPARISON OF TRANSESOPHAGEAL AND TRANSTHORACIC ECHOCARDIOGRAPHY WITH CONTRAST AND COLOR-FLOW DOPPLER IN THE DETECTION OF PATENT FORAMEN OVALE
    BELKIN, RN
    POLLACK, BD
    RUGGIERO, ML
    ALAS, LL
    TATINI, U
    [J]. AMERICAN HEART JOURNAL, 1994, 128 (03) : 520 - 525
  • [3] EFFECT OF POSTURAL STRESS ON LEFT-VENTRICULAR PERFORMANCE USING THE CONTINUOUS-WAVE DOPPLER TECHNIQUE
    BROWN, RA
    MCCORMICK, KA
    VAITKEVICIUS, PV
    FLEG, JL
    [J]. CHEST, 1991, 100 (03) : 738 - 743
  • [4] DETECTION OF PATENT FORAMEN OVALE BY CONTRAST TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    CHEN, WJ
    KUAN, PL
    LIEN, WP
    LIN, FY
    [J]. CHEST, 1992, 101 (06) : 1515 - 1520
  • [5] TRANSCRANIAL DOPPLER ULTRASOUND IDENTIFIES PATIENTS WITH RIGHT-TO-LEFT CARDIAC OR PULMONARY SHUNTS
    CHIMOWITZ, MI
    NEMEC, JJ
    MARWICK, TH
    LORIG, RJ
    FURLAN, AJ
    SALCEDO, EE
    [J]. NEUROLOGY, 1991, 41 (12) : 1902 - 1904
  • [6] TRANSESOPHAGEAL CONTRAST ECHOCARDIOGRAPHY AND COLOR FLOW MAPPING - METHODS OF CHOICE FOR THE DETECTION OF SHUNTS AT THE ATRIAL LEVEL
    DEBELDER, MA
    TOURIKIS, L
    GRIFFITH, M
    LEECH, G
    CAMM, AJ
    [J]. AMERICAN HEART JOURNAL, 1992, 124 (06) : 1545 - 1550
  • [7] Di Tullio M, 1993, Int J Card Imaging, V9, P1
  • [8] COMPARISON OF DIAGNOSTIC-TECHNIQUES FOR THE DETECTION OF A PATENT FORAMEN OVALE IN STROKE PATIENTS
    DITULLIO, M
    SACCO, RL
    VENKETASUBRAMANIAN, N
    SHERMAN, D
    MOHR, JP
    HOMMA, S
    [J]. STROKE, 1993, 24 (07) : 1020 - 1024
  • [9] PATENT FORAMEN OVALE AS A RISK FACTOR FOR CRYPTOGENIC STROKE
    DITULLIO, M
    SACCO, RL
    GOPAL, A
    MOHR, JP
    HOMMA, S
    [J]. ANNALS OF INTERNAL MEDICINE, 1992, 117 (06) : 461 - 465
  • [10] THE INCIDENCE OF PATENT FORAMEN OVALE IN 1,000 CONSECUTIVE PATIENTS - A CONTRAST TRANSESOPHAGEAL ECHOCARDIOGRAPHY STUDY
    FISHER, DC
    FISHER, EA
    BUDD, JH
    ROSEN, SE
    GOLDMAN, ME
    [J]. CHEST, 1995, 107 (06) : 1504 - 1509