Concurrent validity of the Microsoft Kinect for assessment of spatiotemporal gait variables

被引:175
作者
Clark, Ross A. [1 ]
Bower, Kelly J. [2 ]
Mentiplay, Benjamin F. [1 ]
Paterson, Kade [1 ]
Pua, Yong-Hao [3 ]
机构
[1] Australian Catholic Univ, Sch Exercise Sci, Melbourne, Vic, Australia
[2] Univ Melbourne, Dept Physiotherapy, Melbourne, Vic, Australia
[3] Singapore Gen Hosp, Dept Physiotherapy, Singapore, Singapore
关键词
Walk; Gaming; Biomechanics; Physical function; GAITRite; Accelerometer; GAITRITE(R) WALKWAY SYSTEM; PARAMETERS; AGREEMENT; FALLS;
D O I
10.1016/j.jbiomech.2013.08.011
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Spatiotemporal characteristics of gait such as step time and length are often associated with overall physical function in clinical populations, but can be difficult, time consuming and obtrusive to measure. This study assessed the concurrent validity of overground walking spatiotemporal data recorded using a criterion reference - a marker-based three-dimensional motion analysis (3DMA) system - and a low-cost, markerless alternative, the automated skeleton tracking output from the Microsoft Kinect (TM) (Kinect). Twenty-one healthy adults performed normal walking trials while being monitored using both systems. The outcome measures of gait speed, step length and time, stride length and time and peak foot swing velocity were derived using supervised automated analysis. To assess the agreement between the Kinect and 3DMA devices, Bland-Altman 95% bias and limits of agreement, percentage error, relative agreement (Pearson's correlation coefficients: r) overall agreement (concordance correlation coefficients: r(c)) and landmark location linearity as a function of distance from the sensor were determined. Gait speed, step length and stride length from the two devices possessed excellent agreement (rand rc values >0.90). Foot swing velocity possessed excellent relative (r=0.93) but only modest overall (r(c)=0.54) agreement. Step time (r=0.82 and r(c)=0.23) and stride time (r=0.69 and r(c)=0.14) possessed excellent and modest relative agreement respectively but poor overall agreement. Landmark location linearity was excellent (R-2=0.991). This widely available, low-cost and portable system could provide clinicians with significant advantages for assessing some spatiotemporal gait parameters. However, caution must be taken when choosing outcome variables as some commonly reported variables cannot be accurately measured. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2722 / 2725
页数:4
相关论文
共 21 条
[1]   Does freezing in Parkinson's disease change limb coordination? A kinematic analysis [J].
Alice, Nieuwboer ;
Fabienne, Chavret ;
Anne-Marie, Willems ;
Kaat, Desloovere .
JOURNAL OF NEUROLOGY, 2007, 254 (09) :1268-1277
[2]   Gait analysis methods in rehabilitation [J].
Baker, Richard .
JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2006, 3 (1)
[3]   Gait characteristics of elderly people with a history of falls: A dynamic approach [J].
Barak, Yaron ;
Wagenaar, Robert C. ;
Holt, Kenneth G. .
PHYSICAL THERAPY, 2006, 86 (11) :1501-1510
[4]   Concurrent related validity of the GAITRite® walkway system for quantification of the spatial and temporal parameters of gait [J].
Bilney, B ;
Morris, M ;
Webster, K .
GAIT & POSTURE, 2003, 17 (01) :68-74
[5]   CALCULATING CORRELATION-COEFFICIENTS WITH REPEATED OBSERVATIONS .2. CORRELATION BETWEEN SUBJECTS [J].
BLAND, JM ;
ALTMAN, DG .
BRITISH MEDICAL JOURNAL, 1995, 310 (6980) :633-633
[6]   Estimation of the concordance correlation coefficient for repeated measures using SAS and R [J].
Carrasco, Josep L. ;
Phillips, Brenda R. ;
Puig-Martinez, Josep ;
King, Tonya S. ;
Chinchilli, Vernon M. .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2013, 109 (03) :293-304
[7]  
Carstensen B., 2013, METHCOMP FUNCTIONS A, V1, P21
[8]  
Carstensen B., Int J Biostat, DOI DOI 10.2202/1557-4679.1107
[9]   Validity of the Microsoft Kinect for assessment of postural control [J].
Clark, Ross A. ;
Pua, Yong-Hao ;
Fortin, Karine ;
Ritchie, Callan ;
Webster, Kate E. ;
Denehy, Linda ;
Bryant, Adam L. .
GAIT & POSTURE, 2012, 36 (03) :372-377
[10]   A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques [J].
Critchley, LAH ;
Critchley, JAJH .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) :85-91