Determination of antimony by atomic absorption spectrometry with flow injection hydride generation by a tetrahydroborate-form anion-exchanger

被引:19
作者
Rodriguez, Yustina [1 ]
Tyson, Julian F. [1 ]
机构
[1] Univ Massachusetts, Dept Chem, Amherst, MA 01003 USA
关键词
D O I
10.1039/b518042b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A quartz tube atomic absorption spectrometric method for the determination of antimony by FI-HG was developed in which stibine (SbH3) was generated from the reaction between antimony in the injected solution and tetrahydroborate immobilized on a strong anion-exchange resin (Amberlite IRA-400). Several samples could be injected before the column was reloaded. The LOD (3s) in 4 mol l(-1) HCl and 10% cysteine, and 4 mol l(-1) HCl and 10% thiourea, were 0.55 and 0.54 mu g l(-1), respectively. The precision, expressed as % RSD (n = 5), was 5.9, 4.9, 3.8, 2.6 and 1.0 for 5.0, 10.0, 20.0, 40.0 and 60.0 mu g l(-1), respectively, in 4 mol l(-1) HCl and 10% (m/v) L-cysteine; and 8.1, 5.0, 1.5, 1.2 and 1.4 for the same concentrations in 4 mol l(-1) HCl and 10% (m/v) thiourea. The throughput was 60 h(-1). Interferences from transition metals and hydride-forming elements, and signal suppression due to high ionic strength, were eliminated by the addition L-cysteine or thiourea to the samples, which also allowed the acid concentration to be decreased to 0.61 mol l(-1). The method was evaluated by the analysis of spiked sea and well waters, for which no matrix effects were observed: the recoveries for 3.0 and 5.0 mu g l(-1) were 102% and 110-114%, respectively.
引用
收藏
页码:757 / 762
页数:6
相关论文
共 37 条
[21]   Speciation of antimony for the 21st century: promises and pitfalls [J].
Krachler, M ;
Emons, H ;
Zheng, J .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (02) :79-90
[22]   In situ trapping of stibine in externally heated quartz tube atomizers for atomic absorption spectrometry [J].
Kratzer, J ;
Dedina, J .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (06) :859-864
[23]   A NEW CONTINUOUS HYDRIDE GENERATOR FOR THE DETERMINATION OF ARSENIC, ANTIMONY AND TIN BY HYDRIDE GENERATION ATOMIC-ABSORPTION SPECTROMETRY [J].
LE, XC ;
CULLEN, WR ;
REIMER, KJ ;
BRINDLE, ID .
ANALYTICA CHIMICA ACTA, 1992, 258 (02) :307-315
[24]   Determination of lead by hydride generation atomic absorption spectrometry (HGAAS) using a solid medium for generating hydride [J].
Maleki, N ;
Safavi, A ;
Ramezani, Z .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (08) :1227-1230
[25]   Atomic spectrometric detection of hydride forming elements following in situ trapping within a graphite furnace [J].
Matusiewicz, H ;
Sturgeon, RE .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (04) :377-397
[26]   Monitoring of total antimony and its species by ICP-MS and on-line ion chromatography in biological samples from patients treated for leishmaniasis [J].
Miekeley, N ;
Mortari, SR ;
Schubach, AO .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 372 (03) :495-502
[27]  
MILLER JC, 1993, STAT ANAL CHEM, P185
[28]  
Minczewski J., 1982, SEPARATION PRECONCEN, P283
[29]   DETERMINATION OF TRACE CONCENTRATIONS OF ANTIMONY BY THE INTRODUCTION OF STIBINE INTO AN INDUCTIVELY-COUPLED PLASMA FOR ATOMIC EMISSION-SPECTROMETRY [J].
NAKAHARA, T ;
KIKUI, N .
ANALYTICA CHIMICA ACTA, 1985, 172 (JUN) :127-138
[30]  
NARSITO XX, 1991, ANAL CHIM ACTA, V244, P129