Biosensor for phenol based on the direct electron transfer blocking of peroxidase immobilising on silica-titanium

被引:114
作者
Rosatto, SS [1 ]
Kubota, LT [1 ]
Neto, GD [1 ]
机构
[1] UNICAMP, Inst Quim, BR-13083970 Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
modified silica; phenol biosensor; peroxidase;
D O I
10.1016/S0003-2670(99)00168-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Horseradish peroxidase (HRP) was immobilised on silica gel modified with titanium oxide. This material was employed to prepare modified carbon paste electrode. The direct electron transfer of the hydrogen peroxide reduction by HRP was blocked when immobilised on silica-titanium, This biosensor presented a very sensitive response for phenol (1 mu mol l(-1)) at an applied potential of 0 mV vs SCE. The best condition was achieved in phosphate buffer pH 6.8, ratio of hydrogen peroxide/phenol higher than 0.35. The biosensor showed a linear response range between 10 and 50 mu mol l(-1) of phenol, adjusted by the equation j=-32.8+16.3 [phenol], for n=5 with a correlation coefficient of 0.9995. The response time of the biosensor was about 3 s. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:65 / 72
页数:8
相关论文
共 31 条
[11]   CYCLIC VOLTAMMETRIC STUDY OF [FE(CN)6]3-/4- IMMOBILIZED ON SILICA-GEL SURFACE COATED WITH TITANIUM(IV) OXIDE [J].
KUBOTA, LT ;
GUSHIKEM, Y .
ELECTROCHIMICA ACTA, 1992, 37 (13) :2477-2480
[12]   PREPARATION AND CHARACTERIZATION OF TI(IV) OXIDE GRAFTED ONTO SILICA ON A SILICA-GEL SURFACE [J].
KUBOTA, LT ;
GUSHIKEM, Y ;
DECASTRO, S ;
MOREIRA, JC .
COLLOIDS AND SURFACES, 1991, 57 (1-2) :11-15
[13]   Amperometric detection of phenols using peroxidase-modified graphite electrodes [J].
Lindgren, A ;
Emneus, J ;
Ruzgas, T ;
Gorton, L ;
MarkoVarga, G .
ANALYTICA CHIMICA ACTA, 1997, 347 (1-2) :51-62
[14]   EFFECTS OF DIFFERENT ADDITIVES ON A TYROSINASE BASED CARBON-PASTE ELECTRODE [J].
LUTZ, M ;
BURESTEDT, E ;
EMNEUS, J ;
LIDEN, H ;
GOBHADI, S ;
GORTON, L ;
MARKOVARGA, G .
ANALYTICA CHIMICA ACTA, 1995, 305 (1-3) :8-17
[15]  
MAEHLY AC, 1955, METHOD ENZYMOL, V2, P807
[16]   DEVELOPMENT OF ENZYME-BASED AMPEROMETRIC SENSORS FOR THE DETERMINATION OF PHENOLIC-COMPOUNDS [J].
MARKOVARGA, G ;
EMNEUS, J ;
GORTON, L ;
RUZGAS, T .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1995, 14 (07) :319-328
[17]   LIQUID-CHROMATOGRAPHIC RETENTION AND SEPARATION OF PHENOLS AND RELATED AROMATIC-COMPOUNDS ON REVERSED PHASE COLUMNS [J].
MARKOVARGA, G ;
BARCELO, D .
CHROMATOGRAPHIA, 1992, 34 (3-4) :146-154
[18]   Immobilized ferrocene and glucose oxidase on titanium(IV) oxide grafted onto a silica gel surface and its application as an amperometric glucose biosensor [J].
Milagres, BG ;
Kubota, LT ;
Neto, GD .
ELECTROANALYSIS, 1996, 8 (05) :489-493
[19]  
Morrison SR, 1980, US
[20]   SIMULTANEOUS DETERMINATION OF PHENOL, CRESOLS AND XYLENOLS IN WORK PLACE AIR, USING A POLYSTYRENE DIVINYLBENZENE COLUMN AND ELECTROCHEMICAL DETECTION [J].
NIEMINEN, E ;
HEIKKILA, P .
JOURNAL OF CHROMATOGRAPHY, 1986, 360 (01) :271-278