High Precision Measurement of Selenium Isotopic Composition by Hydride Generation Multiple Collector Inductively Coupled Plasma Mass Spectrometry with a 74Se-77Se Double Spike

被引:51
作者
Zhu Jian-Ming [1 ,2 ,3 ]
Johnson, Thomas M. [2 ]
Clark, Scott K. [2 ]
Zhu Xiang-Kun [3 ]
机构
[1] Chinese Acad Sci, Inst Geochem, State Key Lab Environm Geochem, Guiyang 550002, Peoples R China
[2] Univ Illinois, Dept Geol, Urbana, IL 61801 USA
[3] Chinese Acad Geol Sci, Inst Geol, Minist Land & Resources, Key Lab Isotop Geol, Beijing 100037, Peoples R China
关键词
High precision measurement of Selenium isotopes; double spike; thio-cotton; hydride generator; multiple collector inductively couple plasma mass spectrometry;
D O I
10.1016/S1872-2040(08)60075-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method was developed for high precision measurement of selenium isotopes by hydride generator-multiple collector inductively couple plasma mass spectrometry ( HG-MC-ICP-MS) using Se-74-Se-77 double spike and modified thio-cotton purification procedures. Thio-cotton was first used to chemically separate selenium from sample matrix, followed by removing unknown organic matter from thio-cotton using HNO3 + H2O2 for possibly interfering hydride generation. (SeSe)-Se-74-Se-77 double spike allowed us to effectively correct analytical isotope fractionation during sample chemical purification and mass spectrometry measurement. The external reproducibility for standard NIST SRM3149 and MH495, nature sample were 0.1% (2 sigma) and 0.15% - 0.2% (2 sigma) over the course of several months, respectively. Based on the average yield (85%) of Se separation using thio-colton, the minimum quantity of Se needed for isotope analysis was approximately 20 ng. Se isotope ratios was reported relative to NIST SRM3149, house standard delta(82/76)(MH495/RM3149) = -3.44 +/- 0.1)% (2 sigma) which was in agreement with previously published data delta(82/76)(MH495/SRM3149) = -3.04 +/- 0.5% from sample-standard bracketing techniques. Selenium isotopes were measured in several sedimentary samples with a range in delta(82/76) Se between -13.53% and 11.37% relative to NIST SRM3149, these results indicated a wide perspective application of Se isotopes in environmental, geological, agricultural and life field.
引用
收藏
页码:1385 / 1390
页数:6
相关论文
共 17 条
[1]   Scaling NIST SRM 3149 for Se isotope analysis and isotopic variations of natural samples [J].
Carignan, Jean ;
Wen, Hanjie .
CHEMICAL GEOLOGY, 2007, 242 (3-4) :347-350
[2]  
CHRISTOPHER S, 2001, GEOCHEM GEOPHY GEOSY, P2
[3]   Iron isotopes in natural carbonate minerals determined by MC-ICP-MS with a 58Fe-54Fe double spike [J].
Dideriksen, K ;
Baker, JA ;
Stipp, SLS .
GEOCHIMICA ET COSMOCHIMICA ACTA, 2006, 70 (01) :118-132
[4]   Chromium isotopes and the fate of hexavalent chromium in the environment [J].
Ellis, AS ;
Johnson, TM ;
Bullen, TD .
SCIENCE, 2002, 295 (5562) :2060-2062
[5]   Stable isotope fractionation of selenium by natural microbial consortia [J].
Ellis, AS ;
Johnson, TM ;
Herbel, MJ ;
Bullen, TD .
CHEMICAL GEOLOGY, 2003, 195 (1-4) :119-129
[6]  
Haygarth P.M., 1994, SELENIUM ENV, P1
[7]   Determination of selenium in sediment by isotope-dilution inductively coupled plasma mass spectrometry with an octapole reaction cell [J].
Inagaki, K ;
Takatsu, A ;
Nakama, A ;
Eyama, S ;
Yarita, T ;
Okamoto, K ;
Chiba, K .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (01) :67-75
[8]   Selenium isotope ratios as indicators of selenium sources and oxyanion reduction [J].
Johnson, TM ;
Herbel, MJ ;
Bullen, TD ;
Zawislanski, PT .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1999, 63 (18) :2775-2783
[9]   A review of mass-dependent fractionation of selenium isotopes and implications for other heavy stable isotopes [J].
Johnson, TM .
CHEMICAL GEOLOGY, 2004, 204 (3-4) :201-214
[10]   Selenium isotope fractionation during reduction by Fe(II)-Fe(III) hydroxide-sulfate (green rust) [J].
Johnson, TM ;
Bullen, TD .
GEOCHIMICA ET COSMOCHIMICA ACTA, 2003, 67 (03) :413-419