Determination of selenium in sediment by isotope-dilution inductively coupled plasma mass spectrometry with an octapole reaction cell

被引:24
作者
Inagaki, K [1 ]
Takatsu, A [1 ]
Nakama, A [1 ]
Eyama, S [1 ]
Yarita, T [1 ]
Okamoto, K [1 ]
Chiba, K [1 ]
机构
[1] Natl Metrol Inst Japan, Natl Inst Adv Ind Sci & Technol, Environm Stand Sect, Tsukuba, Ibaraki 3058563, Japan
关键词
selenium; sediment; isotope dilution; ICPMS; cation-exchange disk filtration;
D O I
10.1007/s00216-006-0376-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method is described for determination of selenium in sediment by isotope-dilution inductively coupled plasma mass spectrometry with an octapole reaction cell ( ID - ICP - ORCMS). Sediment samples were digested with HNO3, HClO4, and HF, and the digestion included an elaborate evaporation process to remove bromine from the digested solution. Simple strong cation-exchange disk filtration was used to remove rare earth elements (REE) from the digested solution, because REE2+ seriously interfere with Se isotopes (i.e. Gd-156(2+) with Se-78(+), Gd-160(2+) with Se-80(+)). Addition of acetic acid to the filtrate was examined to improve the sensitivity of ICP ORCMS measurement of Se+ by means of a carbon-enhancement effect. The interfering Ar-2(+) for selenium isotopes were almost eliminated by use of H-2 as reaction gas. Interference from BrH+ formed in the reaction cell was negligible because the Br was removed in the evaporation process. Approximately 99.5% of REE were removed by cation-exchange disk filtration yet more than 99% of Se remained in the filtrate solution. The intensity for Se+ was enhanced approximately fourfold by addition of 5% (v/v) of acetic acid whereas that for Ar-2(+) was barely enhanced. Measured Se-80/Se-78 ratios in unspiked digested solutions of the sample were in good agreement with that for an Se standard solution. The analytical results for Se in the certified reference materials MESS-3 and PACS-1 were in good agreement with their certified values, with small uncertainties.
引用
收藏
页码:67 / 75
页数:9
相关论文
共 42 条
[1]   Enzymatic digestion for the determination of trace elements in blood serum by inductively coupled plasma mass spectrometry [J].
AbouShakra, FR ;
Rayman, MP ;
Ward, NI ;
Hotton, V ;
Bastian, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (04) :429-433
[2]   SIGNAL ENHANCEMENT OF ELEMENTS DUE TO THE PRESENCE OF CARBON-CONTAINING COMPOUNDS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
ALLAIN, P ;
JAUNAULT, L ;
MAURAS, Y ;
MERMET, JM ;
DELAPORTE, T .
ANALYTICAL CHEMISTRY, 1991, 63 (14) :1497-1498
[3]   Direct determination of halogens in powdered geological and environmental samples using isotope dilution laser ablation ICP-MS [J].
Boulyga, SF ;
Heumann, KG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2005, 242 (2-3) :291-296
[4]   ICP-MS with hexapole collision cell for isotope ratio measurements of Ca, Fe, and Se [J].
Boulyga, SF ;
Becker, JS .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (05) :618-623
[5]   DETERMINATION OF SELENIUM BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY UTILIZING A NEW HYDRIDE GENERATION SAMPLE INTRODUCTION SYSTEM [J].
BUCKLEY, WT ;
BUDAC, JJ ;
GODFREY, DV ;
KOENIG, KM .
ANALYTICAL CHEMISTRY, 1992, 64 (07) :724-729
[6]   A CRITICAL SURVEY OF HYDRIDE GENERATION TECHNIQUES IN ATOMIC SPECTROSCOPY [J].
CAMPBELL, AD .
PURE AND APPLIED CHEMISTRY, 1992, 64 (02) :227-244
[7]   Selection of the operating conditions for overcoming acids and sodium chloride non-spectroscopic interferences in inductively coupled plasma atomic emission spectrometry:: effect of the liquid-to-vapor mass ratios [J].
Catasús, M ;
Todolí, JL ;
Gras, L ;
Hernandis, V .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (09) :1203-1206
[8]   Detection of metals in proteins by means of polyacrylamide gel electrophoresis and laser ablation-inductively coupled plasma-mass spectrometry:: Application to selenium [J].
Chéry, CC ;
Günther, D ;
Cornelis, R ;
Vanhaecke, F ;
Moens, L .
ELECTROPHORESIS, 2003, 24 (19-20) :3305-3313
[9]   Operational optimisation of ICP -: octopole collision/reaction cell -: MS for applications to ultratrace selenium total and speciation determination [J].
Darrouzès, J ;
Bueno, M ;
Lespès, G ;
Potin-Gautier, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (02) :88-94
[10]   Method development for the determination of cadmium, copper, lead, selenium and thallium in sediments by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry and isotopic dilution calibration [J].
Dias, LF ;
Miranda, GR ;
Saint'Pierre, TD ;
Maia, SM ;
Frescura, VLA ;
Curtius, AJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (01) :117-124