Operational optimisation of ICP -: octopole collision/reaction cell -: MS for applications to ultratrace selenium total and speciation determination

被引:35
作者
Darrouzès, J [1 ]
Bueno, M [1 ]
Lespès, G [1 ]
Potin-Gautier, M [1 ]
机构
[1] Lab Chim Analyt Bioinorgan & Environm, F-64053 Pau, France
关键词
D O I
10.1039/b410142a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the optimisation of inductively coupled plasma-mass spectrometry (ICPMS) equipped with collision/reaction cell (C/RC) technology for selenium analysis at ultratrace level. Gas flow rates for helium and hydrogen were carefully optimised using experimental design methodology in order to efficiently remove interferences (ArAr+ dimer) while keeping maximum sensitivity on Se-80. A mixture of both gases with 0.5 ml min(-1) of He and 3.8 ml min(-1) of H-2 was selected as the best compromise. Voltage of the different ionic lenses disposed around the C/RC, allowing a better focalisation of the ion beam and kinetic energy discrimination, was also investigated and retained values were: - 14 V for quadrupole bias, - 13 V for octopole bias, - 20 V for cell entrance, - 20 V for cell exit and - 45 V for plate bias. Detection limits in total analysis are close to 30 ng (Se) l(-1) which represents a three times improvement to the ones obtained without C/RC. These conditions were tested with HPLC coupling for speciation of selenite (SeIV), selenate (SeVI), selenomethionine ( SeMet) and selenocystine (SeCyst). Depending on selenium species, the detection limits achieved in C/RC mode monitoring Se-80 are in the range 70 - 180 ng (Se) l(-1) which represents a 2 times improvement in comparison with Se-82 monitoring in standard mode. Accuracy of the method was tested by analysing spiked water and certified reference material (Rain water, TM-Rain95, National water research institute, Canada).
引用
收藏
页码:88 / 94
页数:7
相关论文
共 39 条
[1]  
[Anonymous], COMMUNICATION
[2]   ICP-MS with hexapole collision cell for isotope ratio measurements of Ca, Fe, and Se [J].
Boulyga, SF ;
Becker, JS .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (05) :618-623
[3]   Performance of ICP-MS with hexapole collision cell and application for determination of trace elements in bio-assays [J].
Boulyga, SF ;
Dietze, HJ ;
Becker, JS .
MIKROCHIMICA ACTA, 2001, 137 (1-2) :93-103
[4]   Detection of metals in proteins by means of polyacrylamide gel electrophoresis and laser ablation-inductively coupled plasma-mass spectrometry:: Application to selenium [J].
Chéry, CC ;
Günther, D ;
Cornelis, R ;
Vanhaecke, F ;
Moens, L .
ELECTROPHORESIS, 2003, 24 (19-20) :3305-3313
[5]  
D'Ulivo A, 1997, ANALYST, V122, p117R, DOI 10.1039/a704759b
[6]   ANALYTICAL METHODS FOR THE SPECIATION OF SELENIUM-COMPOUNDS - A REVIEW [J].
DAUCHY, X ;
POTINGAUTIER, M ;
ASTRUC, A ;
ASTRUC, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 348 (12) :792-805
[7]   Elemental speciation by chromatographic separation with inductively coupled plasma mass spectrometry detection [J].
de León, CAP ;
Montes-Bayón, M ;
Caruso, JA .
JOURNAL OF CHROMATOGRAPHY A, 2002, 974 (1-2) :1-21
[8]   COLLISIONAL FOCUSING EFFECTS IN RADIO-FREQUENCY QUADRUPOLES [J].
DOUGLAS, DJ ;
FRENCH, JB .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (04) :398-408
[9]   Application of a hexapole collision and reaction cell in ICP-MS Part II: Analytical figures of merit and first applications [J].
Feldmann, I ;
Jakubowski, N ;
Thomas, C ;
Stuewer, D .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (05) :422-428
[10]   Application of a hexapole collision and reaction cell in ICP-MS Part I: Instrumental aspects and operational optimization [J].
Feldmann, I ;
Jakubowski, N ;
Stuewer, D .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (05) :415-421