A comparison of light wand and suspension laryngoscopic intubation techniques in outpatients

被引:41
作者
Friedman, PG
Rosenberg, MK
LebenbomMansour, M
机构
[1] SINAI HOSP,DEPT ANESTHESIOL,FARMINGTON HILLS,MI
[2] WAYNE STATE UNIV,SCH MED,DEPT ANESTHESIOL,DETROIT,MI
[3] MICHIGAN STATE UNIV,COLL OSTEOPATH MED,DEPT SURG SPECIALTIES,E LANSING,MI 48824
关键词
D O I
10.1097/00000539-199709000-00017
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Endotracheal intubation can produce postoperative sore throat and hoarseness, as well as changes in cardiovascular variables. A major goal of ambulatory surgery is the prompt return of patients to their daily activities. Postoperative sore throat may impede this and may decrease patient satisfaction with their anesthetic and surgical experience. We conducted a prospective, randomized study in 40 outpatients having lower extremity arthroscopies to compare the effects of direct laryngoscopy and light wand intubation on cardiovascular changes, sore throat, hoarseness, and dysphagia. Subjects were randomly assigned to either Group A (endotracheal intubation by rigid laryngoscopy) or Group B (endotracheal intubation with a light wand). A standardized anesthetic technique was used. Heart rate and blood pressure were recorded before induction, after induction but before endotracheal intubation, and at 1-min intervals for the first 5 min after intubation. Sixteen to twenty-four hours postoperatively, the incidence and severity of sore throat, hoarseness, and dysphagia was assessed by a follow-up phone call. This study demonstrated no clinically significant difference in cardiovascular variables between the two techniques. Patients had a significantly lower incidence and severity of sore threat, hoarseness, and dysphagia when a light wand was used for intubation. In conclusion, this study suggests that light wand intubation may decrease the incidence and severity of postoperative sore throat, hoarseness, and dysphagia, thereby potentially increasing satisfaction in ambulatory surgical patients. Implications: This prospective, randomized study found that the incidence and severity of postoperative sore throat, hoarseness, and difficulty in swallowing among ambulatory surgical patients is more frequent when they are endotracheally intubated with a rigid laryngoscope than with a light wand. The authors, therefore, recommend more frequent use of the light wand for endotracheal intubation.
引用
收藏
页码:578 / 582
页数:5
相关论文
共 21 条
[21]   LIGHT-WAND INTUBATION FOR CERVICAL-SPINE INJURIES [J].
WEIS, FR .
ANESTHESIA AND ANALGESIA, 1992, 74 (04) :622-622