Flow injection screening and semiquantitative determination of polycyclic aromatic hydrocarbons in water by laser induced spectrofluorimetry -: chemometrics

被引:12
作者
Amador-Hernández, J [1 ]
Fernández-Romero, JM [1 ]
de Castro, MDL [1 ]
机构
[1] Univ Cordoba, Fac Sci, Analyt Chem Div, E-14071 Cordoba, Spain
关键词
polycyclic aromatic hydrocarbons (PAHs); laser induced fluorescence; chemometrics; SIMCA; PLS; flow injection;
D O I
10.1016/S0003-2670(01)01087-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A continuous method is proposed here for the screening and subsequent semi quantitative determination, if required, of polycyclic aromatic hydrocarbons (PAHs) in water. The experimental arrangement is based on the use of a flow injection (B) manifold that enables preconcentration of the analytes on a C-18 minicolumn before their automatic introduction into a flow-cell for detection. An Nd:YAG laser at 355 nm is used as excitation source and fluorescence emission is detected by a charge coupled device. Multivariate information is analysed by soft independent modelling of class analogy (SIMCA) and partial least squares regression type 1 (PLS-1), in order to obtain qualitative and semiquantitative information. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:61 / 69
页数:9
相关论文
共 30 条
[1]  
Adams MJ., 1995, CHEMOMETRICS ANAL SP
[2]   Resolution of a multicomponent polycyclic aromatic hydrocarbon system in micellar media by linear variable angle fluorescence applying distinct chemometric techniques [J].
Amador-Hernández, J ;
Cladera, A ;
Estela, JM ;
López-de-Alba, PL ;
Cerdà, V .
ANALYST, 1998, 123 (11) :2235-2241
[3]  
[Anonymous], 1985, HDB POLYCYCLIC AROMA
[4]   Field test of a novel microlaser-based probe for in situ fluorescence sensing of soil contamination [J].
Bloch, J ;
Johnson, B ;
Newbury, N ;
Germaine, J ;
Hemond, H ;
Sinfield, J .
APPLIED SPECTROSCOPY, 1998, 52 (10) :1299-1304
[5]   DETERMINING CHEMICAL CHARACTERISTICS OF PLUTONIUM SOLUTIONS USING VISIBLE SPECTROMETRY AND MULTIVARIATE CHEMOMETRIC METHODS [J].
CAREY, WP ;
WANGEN, LE .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1991, 10 (1-2) :245-257
[6]   Study on the magnetic-polarization-resonance-synchronous-fluorimetry and its application to simultaneous determination of polycyclic aromatic hydrocarbons [J].
Chen, ZG ;
Ying, M ;
Chen, TS ;
Qiu, XM ;
Li, ZL .
ANALYTICA CHIMICA ACTA, 1998, 367 (1-3) :11-15
[7]   On-the-fly fluorescence lifetime determination with total emission detection in HPLC [J].
Dvorak, MA ;
Oswald, GA ;
VanBenthem, MH ;
Gillispie, GD .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3458-3464
[8]  
Eiroa AA, 1998, ANALYST, V123, P2113
[9]   Artificial neural networks (ANNs) in the analysis of polycyclic aromatic hydrocarbons in water samples by synchronous fluorescence [J].
Ferrer, R ;
Guiteras, J ;
Beltrán, JL .
ANALYTICA CHIMICA ACTA, 1999, 384 (03) :261-269
[10]   PARTIAL LEAST-SQUARES METHODS FOR SPECTRAL ANALYSES .2. APPLICATION TO SIMULATED AND GLASS SPECTRAL DATA [J].
HAALAND, DM ;
THOMAS, EV .
ANALYTICAL CHEMISTRY, 1988, 60 (11) :1202-1208