Method for MRI-guided conformal thermal therapy of prostate with planar transurethral ultrasound heating applicators

被引:70
作者
Chopra, R
Burtnyk, M
Haider, MA
Bronskill, MJ
机构
[1] Sunnybrook & Womens Coll, Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
[2] Univ Hlth Network, Princess Margaret Hosp, Toronto, ON M5G 2M9, Canada
关键词
D O I
10.1088/0031-9155/50/21/001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A method for conformal prostate thermal therapy using transurethral ultrasound heating applicators incorporating planar transducers is described. The capability to shape heating patterns to the geometry of the prostate gland from a single element in a multi-element heating applicator was evaluated using Bioheat transfer modelling. Eleven prostate geometries were obtained from patients who underwent MR imaging of the prostate gland prior to radical prostatectomy. Results indicate that ultrasound heating applicators incorporating multi-frequency planar transducers (4 x 20 mm, f = 4.7 MHz, 9.7 MHz) are capable of shaping thermal damage patterns to the geometry of individual prostates. A temperature feedback control algorithm has been developed to control the frequency, rotation rate and applied power level from transurethral heating applicators based on measurements of the boundary temperature during heating. The discrepancy between the thermal damage boundary and the target boundary was less than 5 mm, and the transition distance between coagulation and normal tissue was less than 1 cm. Treatment times for large prostate volumes were less than 50 min, and perfusion did not have significant impact on the control algorithm. Rectal cooling will play an important role in reducing undesired heating near the rectal wall. Experimental validation of the simulations in a tissue-mimicking gel phantom demonstrated good agreement between the predicted and generated patterns of thermal damage.
引用
收藏
页码:4957 / 4975
页数:19
相关论文
共 50 条
[1]   Multifrequency ultrasound transducers for conformal interstitial thermal therapy [J].
Chopra, R ;
Luginbuhl, C ;
Foster, FS ;
Bronskill, MJ .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (07) :881-889
[2]   Interstitial ultrasound heating applicator for MR-guided thermal therapy [J].
Chopra, R ;
Luginbuhl, C ;
Weymouth, AJ ;
Foster, FS ;
Bronskill, MJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (12) :3133-3145
[3]   Feasibility of linear arrays for interstitial ultrasound thermal therapy [J].
Chopra, R ;
Bronskill, MJ ;
Foster, FS .
MEDICAL PHYSICS, 2000, 27 (06) :1281-1286
[4]  
Croft D.R., 1977, HEAT TRANSFER CALCUL
[5]  
de Zwart JA, 1999, MAGNET RESON MED, V42, P53, DOI 10.1002/(SICI)1522-2594(199907)42:1<53::AID-MRM9>3.0.CO
[6]  
2-S
[7]   Basic principles of thermal dosimetry and thermal thresholds for tissue damage from hyperthermia [J].
Dewhirst, MW ;
Viglianti, BL ;
Lora-Michiels, M ;
Hanson, M ;
Hoopes, PJ .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2003, 19 (03) :267-294
[8]   Combination of transurethral and interstitial ultrasound applicators for high-temperature prostate thermal therapy [J].
Diederich, CJ ;
Nau, WH ;
Burdette, EC ;
Bustany, ISK ;
Deardorff, DL ;
Stauffer, PR .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2000, 16 (05) :385-403
[9]   Catheter-based ultrasound applicators for selective thermal ablation: progress towards MRI-guided applications in prostate [J].
Diederich, CJ ;
Nau, WH ;
Ross, AB ;
Tyreus, PD ;
Butts, K ;
Rieke, V ;
Sommer, G .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2004, 20 (07) :739-756
[10]   Transurethral ultrasound applicators with directional heating patterns for prostate thermal therapy:: In vivo evaluation using magnetic resonance thermometry [J].
Diederich, CJ ;
Stafford, RJ ;
Nau, WH ;
Burdette, EC ;
Price, RE ;
Hazle, JD .
MEDICAL PHYSICS, 2004, 31 (02) :405-413