摘要
Biotin labeling of red cells was tested in dogs as a preclinical study for cell survival. Red cells were labeled with either spacered Biotin-X-NHS (BxNHS) or water-soluble biotin compounds. After reinfusion, biotinylated red cells were detected in small blood samples (5 mu l) with flow cytometry. Improved BxNHS labeling allows an easy detection of positive red cells for almost 100 days, whereas labeling with watersoluble compounds - despite strong labeling during the first days - results in a decrease of label, which prevented a discrimation between labeled and negative cells after about 4 weeks. When biotin labeling of red cells was compared with Cr-51 labeling, slopes of red cell survival were quite similar after the latter were corrected for elution. Survival slopes were linear, and the mean survival time was t=93d. In two blood-donor dogs the slopes of red cell survival where log linear and the mean survival time was t=45d. In conclusion, BxNHS, but not the water-soluble biotin compounds, is a good nonradioactive, nontoxic alternative for red cell survival studies. No health hazards are to be expected from the very low dose of Dimethylformamide, which is used as a solvent for biotin-x-NHS.
引用
收藏
页码:231 / 238
页数:8
相关论文
共 25 条
[1]  
ANDERSEN AC, 1970, HEMATOLOGY, P274
[2]  
BECKMAN DA, 1979, AVIAT SPACE ENV MED, V3, P212
[3]   A NEW COMBINED INTEGRAL-LIGHT AND SLIT-SCAN DATA-ANALYSIS SYSTEM (DAS) FOR FLOW-CYTOMETRY [J].
BEISKER, W .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1994, 42 (01) :15-26
[4]   THE MEASUREMENT OF THE TOTAL VOLUME OF RED-CELLS IN MAN - A NON-RADIOACTIVE APPROACH USING BIOTIN [J].
CAVILL, I ;
TREVETT, D ;
FISHER, J ;
HOY, T .
BRITISH JOURNAL OF HAEMATOLOGY, 1988, 70 (04) :491-493
[5]  
Christian JA, 1996, EXP HEMATOL, V24, P82
[6]   RED BLOOD CELL LIFE SPAN USING DFP32 AS A COHORT LABEL [J].
CLINE, MJ ;
BERLIN, NI .
BLOOD, 1962, 19 (06) :715-&
[7]   RARE-EVENT ANALYSIS-METHODS FOR DETECTION OF FETAL RED-BLOOD-CELLS IN MATERNAL BLOOD [J].
CUPP, JE ;
LEARY, JF ;
CERNICHIARI, E ;
WOOD, JCS ;
DOHERTY, RA .
CYTOMETRY, 1984, 5 (02) :138-144
[8]  
Dale GL, 1996, EXP HEMATOL, V24, P518
[9]   A NEW APPROACH FOR MEASURING THE ERYTHROCYTE LIFE-SPAN WITH A NONRADIOISOTOPE [J].
DEVER, M ;
SMITH, JE ;
HAUSLER, DW .
CLINICA CHIMICA ACTA, 1989, 181 (03) :337-342
[10]  
Green N M, 1975, Adv Protein Chem, V29, P85, DOI 10.1016/S0065-3233(08)60411-8